ENS 49773
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
14:00 Jan 29, 2014 | |
Title | Indications Identified on Control Rod Drive Mechanism Housings |
Event Description | On January 29, 2014, during planned inspections of control rod drive mechanism (CRDM) upper housings, it was determined that the inspection results for some housings did not meet the applicable acceptance criteria. That is, evaluations of the housing indications are being performed under ASME Code,Section XI, IWB-3600, 'Analytical Evaluation of Flaws,' and indications were identified that exceed acceptance criteria specified in the Code. None of the indications were through-wall and there was no evidence of leakage.
The housing indications, varying in depth and length characteristics, were identified in 17 of the 45 CRDM housings inspected. All 45 CRDM housings were inspected, which constituted 100% extent of condition inspection. The plant was in cold shutdown at 0% power for a planned refueling outage at the time of discovery. Replacement or repair actions are in progress and will be completed prior to plant startup from the outage. This condition has no impact to the health and safety of the public. This report is being made in accordance with 10CFR 50.72(b)(3)(ii)(A), since indications were found that did not meet acceptance criteria referenced in ASME Code,Section XI. The licensee notified the NRC Senior Resident Inspector. |
Where | |
---|---|
Palisades Michigan (NRC Region 3) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
Time - Person (Reporting Time:+-2.9 h-0.121 days <br />-0.0173 weeks <br />-0.00397 months <br />) | |
Opened: | Barbara Dotson 11:06 Jan 29, 2014 |
NRC Officer: | Vince Klco |
Last Updated: | Jan 29, 2014 |
49773 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 49773\u003C/a\u003E - \u003Ca href=\"/Palisades\" title=\"Palisades\"\u003EPalisades\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EIndications Identified on Control Rod Drive Mechanism Housings\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 49773 - Palisades\n","link":"","lat":42.32339722222222,"lon":-86.31451666666666,"icon":"/w/images/7/79/Entergy_icon.png"}],"imageoverlays":null} | |
WEEKMONTHYEARENS 548972020-09-11T23:30:00011 September 2020 23:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | Degraded Condition ENS 537492018-11-21T05:00:00021 November 2018 05:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Identified During Surface Inspection of Reactor Head Nozzle Penetration ENS 537342018-11-11T04:00:00011 November 2018 04:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Indication During Ultrasonic Inspection of Reactor Head Nozzle Penetration ENS 537332018-11-10T05:00:00010 November 2018 05:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Boric Acid Identified on Reactor Vessel Head Penetration ENS 527222017-05-02T13:28:0002 May 2017 13:28:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Failed Ultrasonic Testing of Weld ENS 497962014-02-05T18:00:0005 February 2014 18:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Discovered on Pressurizer Nozzle Weld During Testing ENS 497732014-01-29T14:00:00029 January 2014 14:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Indications Identified on Control Rod Drive Mechanism Housings ENS 481822012-08-12T08:18:00012 August 2012 08:18:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Reported Based on the Discovery of Pressure Boundary Leakage ENS 411282004-10-16T21:30:00016 October 2004 21:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Vessel Head Nozzle Cracking 2020-09-11T23:30:00 [Table view] | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_49773&oldid=422513"