The following information was obtained from the state of
Minnesota via email:
Minnesota Dept. of Health [MDH] was notified by phone message March 10, 2017. The message was retrieved March 13, 2017 by the RAM [Radioactive Material] unit Supervisor. MDH visited the site March 13, 2017 and gathered the following information regarding the source holder.
Category: External EMS Housings
Source Model: P-2608-100 (Co-60)
Gauge Model: LB 300 ML
Manufacture Date: 10/2013
Manufacturer: Berthold Systems, Inc.
Source Number: 1816-10-13 (mold housing 12)
Original Activity: 1.5 mCi
Current Activity: 1.4050 mCi
The licensee is a steel processor and the incident involved molten steel encasing the source holder, locking the shutter in an open position. This is not a typical occurrence. The licensee is working with a consultant (Applied Health Physics) to develop a plan for removing the source holder from the mold and determining whether the source holder is repairable or if it needs to be disposed of.