On February 21, 2017, DBI Inc. had an industrial radiography source disconnect incident occur while at a pipeline customer's field site in Rutledge, MO (approx. 4hrs. from Overland Park, KS office). At approximately 1323
CST during the crew's first source retraction it was determined that the source had become disconnected from the drive cable. The crew immediately recognized the situation through the use of their dosimetry equipment and established the emergency 2 mR/hr boundaries.
The Corporate Radiation Safety Officer (CRSO) was immediately notified of the issue. The CRSO informed the crew to maintain surveillance of the restricted area barricades and to wait until he arrived before any further actions were taken. The CRSO arrived at the job site at approximately 1705 CST to retrieve the source. The source was secured back into the exposure device by 1730 CST. The CRSO received less than 1 mR during the retrieval procedure.
Listed below are the manufacturer and model number of equipment involved in the incident:
- QSA Global 880 Delta Exposure Device
- QSA Global lr-192 Source (45 Curies) Model A424-9
- QSA Global 35 foot Extreme Weather Control Cables
- QSA Global 7 foot Extreme Weather Source Tube with a 4hvl Collimator
The level II radiographer involved holds a current
Iowa Industrial Radiographer Trainer Card and the assistant is a trainee.