The following report was received via e-mail:
Scrap alarm was received at Gerdau Ameristeel, Jacksonville. Scrap bales were from KAS Metals (1912 Elman St. Orlando). Radiation surveys conducted with a Radcomm read 500 mR/hr at the front of trailer and 300 mR/hr at 2 meters. Readings in the cab were 10 mR/hr. All reading and units were confirmed. Due to the reading exceeding DOT levels the load was not granted an exemption and was left in a secure area until Bureau [Florida Bureau of Radiation Control] personnel arrive. The driver left Orlando at 1030 EDT and arrived in Jacksonville at 1430 EDT. The driver [works for] for CPG Enterprises.
Florida event number: FL15-057
- * * UPDATE ON 6/16/15 AT 1208 EDT * * *
The following was received via e-mail:
The source was found to be a broken Troxler handle assembly, [containing] 8 mCi of Cs-137, Dated April 1999, Serial# 50-5034, (ALT 60-5034) 1.5 R/hr [on contact] Issued Sample Tag # Z-011
Notified R1DO (Bickett) and
NMSS Events Notification (email).