The following information was provided by the State of
South Carolina via email:
Shertech Pharmacy (SC Radioactive Material License No. 531) in Spartanburg, SC, reported a
spill of 100mCi of
I-131. A pharmacist dropped the
iodine vial on the pharmacy floor. Most of the contamination was on the floor and the shoes of the pharmacist. The Radiation Safety Officer and pharmacist began clean-up procedures. Clothes and shoes were placed in zip lock bags. The floor was cleaned with Radiac wash and the cleaning items were placed in zip lock bags. Activated charcoal was placed on the floor. The four individuals present did take Lugol's solution. Zip lock bags containing the contaminated items were placed in the fume hood. No contamination was found on the skin of any of the individuals involved. Readings of 0.6 mR/hr are measured outside of the closed room. The licensee will perform bioassays at 24, 48, and
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> on the four individuals present during the
spill and clean up. The primary contamination appeared to be on the shoes themselves.