ENS 49985
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
05:23 Apr 2, 2014 | |
| Title | Secondary Containment Inoperable Due to Two Air Lock Doors Open Simultaneously |
| Event Description | At 0123 EDT on April 2, 2014, Nine Mile Point Unit 2 was in Mode 5, Refueling, and in the other specified condition of Operations with Potential for Draining the Reactor Vessel. During this condition both redundant personnel airlock doors were open at the same time in an airlock penetration of the reactor building. This condition represents a loss of Secondary Containment safety function. Technical Specification 3.6.4.1, Action A.1 was entered for the loss of Secondary Containment and was promptly exited when the doors were closed.
Secondary containment being inoperable is an 8-hour report per 10 CFR 50.72(b)(3)(v)(C), Any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Nine Mile Point New York (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material | |
| Time - Person (Reporting Time:+3.32 h0.138 days <br />0.0198 weeks <br />0.00455 months <br />) | |
| Opened: | Dan Cifonelli 08:42 Apr 2, 2014 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Apr 2, 2014 |
| 49985 - NRC Website
Loading map... | |
Nine Mile Point | |
WEEKMONTHYEARENS 529962017-09-30T05:34:00030 September 2017 05:34:00
[Table view]10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Declared Inoperable ENS 519692016-06-01T14:46:0001 June 2016 14:46:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Nine Mile Point Unit 1 Momentary Loss of Secondary Containment ENS 518562016-04-07T21:30:0007 April 2016 21:30:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Doors of Secondary Containment Open Simultaneously ENS 512892015-08-05T16:52:0005 August 2015 16:52:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 508602015-03-03T13:37:0003 March 2015 13:37:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment Due to Both Airlocks Opening at Same Time ENS 508132015-02-12T00:41:00012 February 2015 00:41:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Nine Mile Point Momentary Loss of Secondary Containment ENS 507322015-01-13T00:39:00013 January 2015 00:39:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Degraded Secondary Containment Differential Pressure ENS 505532014-10-20T17:53:00020 October 2014 17:53:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Secondary Containment Airlock Doors Open Simultaneously ENS 505422014-10-16T14:42:00016 October 2014 14:42:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 503632014-08-14T03:18:00014 August 2014 03:18:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 501872014-06-11T00:32:00011 June 2014 00:32:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Declared Inoperable ENS 499852014-04-02T05:23:0002 April 2014 05:23:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable Due to Two Air Lock Doors Open Simultaneously ENS 499482014-03-24T04:31:00024 March 2014 04:31:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable and Unplanned Isolation of the Reactor Building Vent Radiation Monitor ENS 499062014-03-12T18:22:00012 March 2014 18:22:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable and Unplanned Isolation of Building Vent Radiation Monitor ENS 490432013-05-15T23:34:00015 May 2013 23:34:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Primary Containment Airlock Non-Functional Due to Degraded Seal on Inner Door Concurrent with Personnel Passing Through the Outer Door ENS 473682011-10-24T05:52:00024 October 2011 05:52:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Divisions of the Rwcu High Differential Flow Isolation Function Removed from Service 2017-09-30T05:34:00 | |