ENS 49904
ENS Event | |
|---|---|
04:00 Jan 11, 2014 | |
| Title | Part 21 - Ap-1000 Solenoid Operated Valves Leakage |
| Event Description | The following was excerpted from a fax received from Valcor Engineering Corporation:
Background: Valcor was chosen by WEC [Westinghouse Electric Corporation] as a supplier to the AP-1000 for the ASME Section Ill Class 1, 2 and 3 Solenoid Operated Valves. As part of the specification requirements Valcor is required to perform qualification testing in accordance with the requirements of IEEE-323-1974, IEEE-344-1987 and IEEE-382-1996. Discovery: On Saturday January 11th, 2014, Valcor's lab technician discovered that the hard faced seat of an AP-1000 Solenoid Operated qualification valve had a crack through the thickness of the valve seat to the outlet port that caused the valve to leak in the closed position beyond its Technical Specification requirement (WEC Specification APP-PV13-ZOD-101). The subject valve had undergone heat rise testing to determine actuator temperatures during its specified design basis conditions. As part of the qualification process (IEEE-323) and in accordance with the test procedure the subject valve is given a factory acceptance test (FAT) at each stage of the qualification program. The valve design is unique to the model (V526-5631-36/40) in that the dimensional constrain resulted in a web thickness of the hard faced seat that is thinner than our standard historical valve designs. A total of eight (8) valves of this configuration (four (4) for Valve Model Number V525-5631-36 and four (4) for Model number V526-5631-40) have been delivered to Westinghouse for installation in the Sanmen and Haiyang nuclear power plants located in the People's Republic of China. Neither of these plants have loaded fuel or are operational. The investigation, failure analyses, and stress analyses completed to-date have not provided a firm conclusion of the root cause of the crack. Westinghouse, the purchaser who imposed 10CFR21 on the procurement document of the valve models identified in question, has been informed of the condition and current status of investigation. Submitted by Jimmy Shieh Quality Assurance Director.
Subject: An update to Interim Report initially filed on 3/12/14, revised 3/13/14 Reference: SKA23651 previously submitted Investigation activities since the Interim Report: Computer Flow and Thermal Analysis conducted from March to April 2014. Finite Element Stress Analysis rerun using Computer Flow and Thermal Analysis in April 2014. Both analysis above suggest that the design is adequate and that stress induced by rapid temperature rise would not cause the seat to crack. With Westinghouse assistance and permission [two] 2 production valves were disassembled and NDE (Visual, LP, radiographic, and Eddy current) of body seat area performed during May. The examinations did not identify any defect in the valve seat area. Contrary to all stress/thermal analysis, cracking of valve seat was reproduced early June when one of the above mentioned bodies was subjected to the same thermal shock condition that caused the initial observed cracking. The second valve was tested at the same pressure and end temperature without the thermal shock. The valve seat remained intact without cracking. Westinghouse has been supporting the Part 21 investigation that Valcor is leading. Westinghouse has reviewed all metallurgy, CFD, FEA, NDE, heat rise laboratory and other data Valcor collected during our thorough investigation. All of this information is currently being evaluated by Westinghouse. At this time, the only outstanding issue is for Westinghouse to review all AP1000 transient conditions that are applicable to PV13 solenoid valves. Westinghouse anticipates having the preliminary transient research completed imminently and estimates to take until Nov. 30, 2014 to have all calculations and transient research validated. As stated in the original notification, the condition does not affect any operating plant. Affected valves are limited to overseas construction, none have been installed to date. Notified R2DO (Hopper) and NRR Part 21 Group via email.
Westinghouse has informed Valcor that none of the affected valves have been installed and they are quarantined from accidental installation. Valcor therefore is not required to pursue 10CFR21 reporting further and we [Valcor] consider the report closed. Notified R2DO (Seymour) and NRR Part 21 Group via email. |
| Where | |
|---|---|
| Valcor Engineering Corporation, Valcor Springfield, New Jersey (NRC Region 1) | |
| Organization: | Valcor Engineering Corporation |
| Reporting | |
| 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component | |
| Time - Person (Reporting Time:+1455.4 h60.642 days <br />8.663 weeks <br />1.994 months <br />) | |
| Opened: | Jimmy Shieh 18:24 Mar 12, 2014 |
| NRC Officer: | Charles Teal |
| Last Updated: | Sep 5, 2014 |
| 49904 - NRC Website
Loading map... | |
Valcor with 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component | |
WEEKMONTHYEARENS 559992022-05-19T04:00:00019 May 2022 04:00:00
[Table view]10 CFR 21.21(d)(3)(i), Failure to Comply or Defect, 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 Report - Potential Premature Failures of Valcor Coil Shell Assemblies ENS 507992015-02-09T05:00:0009 February 2015 05:00:00 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 Report - Possible Assembly Error in Solenoid Valve ENS 499042014-01-11T04:00:00011 January 2014 04:00:00 10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component Part 21 - Ap-1000 Solenoid Operated Valves Leakage 2022-05-19T04:00:00 | |