ENS 49581
ENS Event | |
|---|---|
06:00 Nov 7, 2013 | |
| Title | Part 21 Report - Improper Dedication of Actuator Parts |
| Event Description | The following information was received via fax:
Equipment affected by this information notice: Items subject to this Fisher Information Notice (FIN) were provided to Westinghouse Electric Company, LLC (WEC) via Fisher Order Number 004-X012140579, Items 25, 25A, 25B, and 25C (Westinghouse PO# 4500280610). The valves included Type 657NS2 Size 80 Actuators (Equipment). The equipment is identified by Fisher Serial Numbers 19073487, 19073488, 19073489, and 19073490 (Westinghouse Tag Numbers APP-PXS-PL-V014A, APP-PXS-PL-V014B, APP-PXS-PL-V015A, and APP-PXS-PL-V015B). Purpose: The purpose of this FIN is to alert WEC that as of 07 November 2013, Fisher Controls International LLC (Fisher) became aware of a situation which may affect the performance of the Equipment, including their safety-related function. Fisher is informing WEC of this circumstance in accordance with Section 21.21 (b) of 10 CFR 21. Applicability: This FIN applies only to the subject equipment supplied by Fisher to WEC via the aforementioned order. Discussion: Fisher has determined that the subject valves were provided with actuator parts that had not been properly processed per active valve requirements. Specifically, Fisher provided commercial grade parts instead of commercial grade dedicated items. The parts are identified per Fisher Type III drawing GE40372, find numbers 118, 121, and 122. Action Required: Fisher will support WEC in performing the disassembly and replacement of these parts, at no cost to WEC, on the installed actuators. Arrangements will be made with WEC to retrofit the correctly processed and dedicated parts on the subject serial numbers. In addition, a Corrective Action Request (CAR 1661) has been initiated by Fisher to prevent reoccurrence of this issue. 10 CFR 21 Implications: Fisher requests that the recipient of this notice review it and take appropriate action in accordance with 10 CFR 21. If there are any technical questions or concerns, please contact: George Baitinger Manager, Quality Fisher Controls International LLC 301 South First Avenue Marshalltown, IA 50158 Fax: (641) 754-2854 Phone: (641) 754-2026 George.Baitinger@Emerson.com |
| Where | |
|---|---|
| Fisher Controls International Marshalltown, Iowa (NRC Region 3) | |
| Organization: | Fisher Controls International |
| Reporting | |
| 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
| Time - Person (Reporting Time:+462.33 h19.264 days <br />2.752 weeks <br />0.633 months <br />) | |
| Opened: | Chad Engle 12:20 Nov 26, 2013 |
| NRC Officer: | Charles Teal |
| Last Updated: | Nov 26, 2013 |
| 49581 - NRC Website | |
Fisher Controls International with 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
WEEKMONTHYEARENS 542382019-08-23T05:00:00023 August 2019 05:00:00
[Table view]10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Notification - Loose Butterfly Valve Taper Pins ENS 534892018-05-07T05:00:0007 May 2018 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Notification - Hex Nuts and Cap Screws on Certain Vee-Ball Valves Not Properly Dedicated ENS 530772017-09-28T06:00:00028 September 2017 06:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Corrective Action for Fisher Information Notice 2015-01 Insufficient ENS 502912014-06-26T05:00:00026 June 2014 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Incorrect Valve Solenoids Provided ENS 495812013-11-07T06:00:0007 November 2013 06:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Improper Dedication of Actuator Parts 2019-08-23T05:00:00 | |