ENS 49104
ENS Event | |
|---|---|
05:00 Jun 9, 2013 | |
| Title | Agreement State Report - Potential Overexposure |
| Event Description | The State of Kansas was notified by the licensee that on 6/9/2013, personnel dosimetry indicated that one assistant radiographer had received a potential overexposure, and two other assistant radiographers had received potential elevated exposure. The licensee reported that the dosimetry had been stored improperly and in close proximity to a location where a source change out had occurred. Corrective actions taken by the licensee include establishment of a controlled dosimetry storage location and additional training of personnel on the use of dosimetry. The individual with the potential overexposure was removed from radiography duties and given alternate work assignments. All three individuals were notified of the dosimetry readings.
The dosimeter readings were 5.046 rem, 1.133 rem and 0.633 rem.
The following information was obtained from the State of Kansas via fax: Based on the last dosimetry report [received by the licensee], several employees have received a high dose. The reported doses are Employee 1 - 5046 mR, Employee 2 - 1133 mR, and Employee 3 - 633 mR. The three employees are radiographers assistants acting under one of the 4 licensed radiographers. The three radiographers assistants never worked together on any single job. The only common denominator between the three assistants is that their film badges were stored in the same general area. The licensed radiographers that were assigned to them received no such high dose rates. The three assistants also did not have any off-scale readings from dosimetry nor did they report any unusual incidences. All three also stated they did not believe that they could possibly have received an unusually high dose during that time period based on dosimetry, rate alarm, and survey meter readings. Upon further investigation, it was discovered that the three were leaving their film badges in their [work] uniforms in a controlled area within the shop between shifts. During this time period, radiographic operations were conducted at the shop facility. Additionally, there was a source change conducted by two radiographers in the controlled area of the shop during this time. During times these employees were not working, their [work] uniforms would have been located in the controlled area allowing their badges to be exposed during radiographic operations. In conclusion, there are two possible explanations for the substantial increases in exposure to the three assistants badges. Conclusion one would be that excessive heat and humidity played a role in the increased readings found with the badges. Conclusion two would involve film badges in close proximity to the area where radiographic operations were being conducted with the individuals assigned to those badges being absent at the time, therefore creating an erroneous reading leading to the obvious assumption that the badges alone were exposed, not the individuals associated with these badges being exposed. Corrective action taken at this time: Badges will be stored in the office, [with the proper controls in place] when not being worn. Retraining [was] conducted on the physical properties of the film badge and how badges become exposed through various means. Based on the reading of employee 1's badge, he will not be involved in radiographic operations nor be allowed in the controlled areas near radiation in the shop until a full investigation is completed. The State of Kansas is still investigating this event. Kansas Case No.: KS130005 Notified R4DO (Walker) and FSME Events Resource via email. |
| Where | |
|---|---|
| Coder X-Ray Services Mcpherson, Kansas (NRC Region 4) | |
| License number: | 21-B165-01 |
| Organization: | Kansas Dept Of Health & Environment |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+53.98 h2.249 days <br />0.321 weeks <br />0.0739 months <br />) | |
| Opened: | James Harris 10:59 Jun 11, 2013 |
| NRC Officer: | Nestor Makris |
| Last Updated: | Jun 17, 2013 |