ENS 48772
ENS Event | |
|---|---|
10:28 Feb 20, 2013 | |
| Title | Degraded Condition - Containment Penetration Fails Local Leak-Rate Testing |
| Event Description | On February 20, 2013, at 0538 EST, local leak-rate testing (LLRT) of the 'A' feedwater check valves 2B21-F010A and 2B21-F077A revealed that neither valve would pressurize. Based on this information this line would not remain water filled post-LOCA and would result in the 'as found' minimum pathway leakage exceeding the limiting condition of operation (LCO) for Technical Specification 3.6.1.1. The cause for the LLRT failures will be determined and required corrective maintenance will be performed and valves successfully tested during the current refueling outage.
The licensee notified the NRC Resident Inspector.
Subsequent investigation into the reported LLRT failure revealed that the initial LLRT performed on feedwater check valve 2B21-F010A was not considered an acceptable test, since that LLRT was not representative of the 'as found' condition of this check valve. The test volume for this valve had been slowly filled such that the check valve did not have the normal expected differential pressure across the valve disc to achieve normal check valve seating. After draining the test volume and refilling it by allowing the test volume to gravity fill from the reactor pressure vessel, the expected differential pressure across the valve disc occurred and seated the disc in such a way that it was more representative of the 'as found' condition for the check valve. An LLRT was then performed with a leakage of 50 accm [actual cubic centimeters per minute] against an acceptance criterion of 194 accm. No maintenance or operation of the check valve had occurred between the initial invalid test and the subsequent test performed with the disc in its 'as found' condition. An engineering evaluation was performed that documented the acceptability of using this means for establishing the test volume for feedwater check valves 2B21-F010A and 2B21-F010B for the 'A' and 'B' loops of feedwater, respectively. This engineering evaluation concluded that establishment of the required test volume in the manner described for primary containment penetration 9A satisfies the Hatch LLRT program requirements and that the leakage acceptance criterion for feedwater check valve 2B21-F010A in its 'as found' state was satisfied. The 2B21-F077A valve will be retested at a later date. Based on this information, the LLRT of this check valve in its 'as found' state was successful which actually resulted in successful minimum pathway leak rate test results for primary containment penetration 9A. These conclusive test results clearly indicated that the initial test results were incorrect and the 'as found' condition of this penetration isolation capability did not represent a significant degradation of a principal safety barrier as described in 10CFR50.72(b)(3)(ii)(A). For these reasons Notification # 48772 is being retracted. The licensee notified the NRC Resident Inspector. Notified the R2DO (McCoy). |
| Where | |
|---|---|
| Hatch Georgia (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| Time - Person (Reporting Time:+-0.12 h-0.005 days <br />-7.142857e-4 weeks <br />-1.64376e-4 months <br />) | |
| Opened: | Jim Anderson 10:21 Feb 20, 2013 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Feb 22, 2013 |
| 48772 - NRC Website
Loading map... | |
WEEKMONTHYEARENS 575672025-02-22T16:11:00022 February 2025 16:11:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 569592024-02-11T15:11:00011 February 2024 15:11:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 563422023-02-07T22:38:0007 February 2023 22:38:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 544632020-01-04T16:09:0004 January 2020 16:09:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 525672017-02-20T04:23:00020 February 2017 04:23:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Containment Penetration Exceeded Allowable Leakage ENS 517422016-02-16T11:31:00016 February 2016 11:31:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Weld Overlay Flaw Did Not Meet Acceptance Criteria ENS 487952013-02-28T16:55:00028 February 2013 16:55:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Closed Cooling Water Isolation Valve Fails Local Leak Rate Test ENS 487722013-02-20T10:28:00020 February 2013 10:28:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition - Containment Penetration Fails Local Leak-Rate Testing ENS 440382008-03-06T09:00:0006 March 2008 09:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pin Hole Leak Discovered in 1 Inch Instrument Line During Rpv Pressure Test ENS 440052008-02-23T21:00:00023 February 2008 21:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Unacceptable Flaw in Rpv Cap-To-Pipe Weld ENS 432242007-03-09T05:30:0009 March 2007 05:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Main Steam Line Flow Instrument Line Pressure Boundary Leakage ENS 423722006-02-23T23:50:00023 February 2006 23:50:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition of Shroud Tie Rods 2025-02-22T16:11:00 | |