Initial Concern: Valve, serial number 73386, does not consistently return to the closed position.
Nature of the Defect: A dent in the plunger guide may prevent the valve from changing state.
Number and Location of Components:
Model: U0204GBBR-AA Quantity: 32 Customer: EXELON LIMERICK,
Model: U0204GBBR-DEEL Quantity: 30 Customer: ALABAMA POWER FARLEY
Model: U0204GBBR-DE Quantity: 4 Customer: ALABAMA POWER FARLEY
Model: U0204FBBR-DE Quantity: 8 Customer: RALPH A. HILLER
Model: U0204GBBR-DEL Quantity: 4 Customer: DRESSER MASONEILAN
Model: U0204GBBR-DEP Quantity: 3 Customer: DRESSER MASONEILAN
Advice to Purchasers:
Any of the valves identified above may be inspected by removing the coil and checking the plunger guide for any defects. A dent which will prevent plunger movement is noticeable without magnification. It typically occurs approximately 0.10 inches from the base of the valve. Any valves thought to contain defects will be rebuilt or replaced by Automatic Valve.