ENS 43883
ENS Event | |
|---|---|
14:00 Jan 5, 2008 | |
| Title | Safety Equipment Failure of the Criticality Alarm System |
| Event Description | SNM-124 Section 12.6.4 requires that criticality alarm system detector pairs must generate an alarm signal when both detectors in a pair exceed their trip point, or when one detector is in a fault condition while the other exceeds the alarm trip point.
During testing, 2 of 18 detector pairs did not generate an alarm signal in all modes as discussed above. In the event of a criticality, 2 detector pairs may not have generated an alarm signal. During 27 December 2007 through 29 December 2007, a programmable logic controller (PLC) monitoring system was attached to the critical alarm system components. On 29 December 2007, all detector pairs were satisfactorily tested that they would generate an alarm signal when required. During 31 December 2007 until 5 January 2008, limited SNM operations were conducted at the plant. Suspect equipment faults occurred during the time frame from 29 December 2007 to 5 January 2008 due to unknown cause. Troubleshooting revealed an equipment fault in each detector pair that failed during testing. These faults have been corrected and the detector pairs satisfactorily retested. The two (2) affected detector pairs are located in the NDA North & South and Building 311 North & South. There were no recorded trouble alarms generated by the operable detector in the affected areas during the week when the system was not functioning properly. Also, there is no indication of tampering in that the fault was identified as loose wiring/connections inside locked cabinets accessible to authorized personnel only. The licensee informed the NRC Resident Inspector. |
| Where | |
|---|---|
| Nuclear Fuel Services Inc. Erwin, Tennessee (NRC Region 2) | |
| License number: | SNM-124 |
| Reporting | |
| 10 CFR 70.50(b)(2) | |
| Time - Person (Reporting Time:+3.05 h0.127 days <br />0.0182 weeks <br />0.00418 months <br />) | |
| Opened: | Charles Street 17:03 Jan 5, 2008 |
| NRC Officer: | Steve Sandin |
| Last Updated: | Jan 5, 2008 |
| 43883 - NRC Website | |
Nuclear Fuel Services Inc. with 10 CFR 70.50(b)(2) | |
WEEKMONTHYEARENS 559022022-05-18T18:50:00018 May 2022 18:50:00
[Table view]10 CFR 70.50(b)(2) Criticality Accident Alarm System Speakers Disabled ENS 542182019-08-13T20:00:00013 August 2019 20:00:00 10 CFR 70.50(b)(2) Criticality Accident Alarm System Speaker Failure ENS 524042016-12-01T15:14:0001 December 2016 15:14:00 10 CFR 70.50(b)(2) Office Area Alarm Audibility Disabled ENS 523582016-11-09T16:15:0009 November 2016 16:15:00 10 CFR 70.50(b)(2) Insufficient Alarm Audibility ENS 521902016-08-17T21:39:00017 August 2016 21:39:00 10 CFR 70.50(b)(2) Failure of a Speaker in an Area Potentially Requiring Personnel Evacuation ENS 499982014-04-04T17:15:0004 April 2014 17:15:00 10 CFR 70.50(b)(2) Criticality Accident Evacuation Alarm Not Audible in Certain Areas Outside the Material Handling Area ENS 498482014-02-21T13:39:00021 February 2014 13:39:00 10 CFR 70.50(b)(2) Audibility of Alarm System ENS 460862010-07-12T16:00:00012 July 2010 16:00:00 10 CFR 70.50(b)(2) Electrical Fault Disabled Public Address System Which Supports Various Alarm Annunciators ENS 451792009-06-30T20:00:00030 June 2009 20:00:00 10 CFR 70.50(b)(2) Safety Equipment Failure of the Criticality Alarm System ENS 438832008-01-05T14:00:0005 January 2008 14:00:00 10 CFR 70.50(b)(2) Safety Equipment Failure of the Criticality Alarm System ENS 422262005-12-22T19:00:00022 December 2005 19:00:00 10 CFR 70.50(b)(2), 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Safety Equipment Failure 2022-05-18T18:50:00 | |