| Title | Momentary Loss of Shutdown Cooling Due to Rhr Isolation Signal |
| Event Description | On November 27, 2006 Fort Calhoun Station was on shutdown cooling, while in the process of moving the plant from Mode 3 to Mode 4 to fix a leak on an In-Core Instrument (ICI) Grayloc fitting. At 1327 Reactor Coolant Pump RC-3B was secured. At 1330, the last Reactor Coolant Pump (RC-3A) was secured. Once the reactor coolant pumps were secured, spray to the pressurizer was lost. This loss of pressurizer spray caused pressure in the pressurizer to rise; the systems pressure interlock caused HCV-347, Shutdown Cooling Loop 2 Outboard Isolation Valve, and HCV-348, Loop 2 to Shutdown Cooling Isolation Valve to close due to pressurizer pressure being greater than 250 psia.
At 1330 the Control Room entered AOP-19 for a Loss of Shutdown Cooling. The control room operators initiated auxiliary spray, lowered pressure, reopened HCV-347/348, and started Low Pressure Safety Injection Pump SI-1A. At 1342 shutdown cooling was reestablished. At 1352 all conditions to exit AOP-19 were met and the procedure was exited. During the 12 minutes that shutdown cooling was lost the highest pressure reached in the RCS was 254 psia up from 233 psi and the highest temperature was 135 degrees, up from 134 degrees as read on the core exit thermocouples. The licensee informed the NRC Resident Inspector. |
| Where | |
|---|---|
| Fort Calhoun Nebraska (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat | |
| Time - Person (Reporting Time:+-2.72 h-0.113 days <br />-0.0162 weeks <br />-0.00373 months <br />) | |
| Opened: | Chuck Marasco 16:47 Nov 27, 2006 |
| NRC Officer: | Steve Sandin |
| Last Updated: | Nov 27, 2006 |
| 43013 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Not Critical |
| Scram | No |
| Before | Hot Standby (0 %) |
| After | Hot Shutdown (0 %) |