ENS 41503
ENS Event | |
|---|---|
19:00 Mar 18, 2005 | |
| Title | Other Unspecified Requirement - License Condition 2.C |
| Event Description | The following information was obtained from the licensee via facsimile (licensee text in quotes):
Report of a violation of the Technical Requirements contained in section 2C of the operating license, which requires initial notification within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to the NRC via the ENS with written follow-up within 30 days. A recent failure of the 'A' CRD pump to start required maintenance on an associated local shutdown panel. Troubleshooting indicated that a relay associated with the panel was the cause of the breaker for the pump to not be set up for a remote start from the control room. The relay in question malfunctioned on Feb. 17th so the 'A' CRD pump was not available since that time. The failure of this pump requires entry into a 7-day shutdown LCO. Troubleshooting, indicated there is firm evidence that this condition, which is prohibited by technical specifications, existed before the discovery on 3/16/5. A 7-day LCO was entered upon discovery and repairs have been completed and the LCO exited. The licensee has notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Oyster Creek New Jersey (NRC Region 1) | |
| Reporting | |
| Other Unspec Reqmnt | |
| Time - Person (Reporting Time:+0.62 h0.0258 days <br />0.00369 weeks <br />8.49276e-4 months <br />) | |
| Opened: | Frank Ciganik 19:37 Mar 18, 2005 |
| NRC Officer: | Howie Crouch |
| Last Updated: | Mar 18, 2005 |
| 41503 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 41503\u003C/a\u003E - \u003Ca href=\"/Oyster_Creek\" title=\"Oyster Creek\"\u003EOyster Creek\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EOther Unspecified Requirement - License Condition 2.C\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 41503 - Oyster Creek\n","link":"","lat":39.81436111111111,"lon":-74.20560833333333,"icon":""}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Oyster Creek with Other Unspec Reqmnt | |
WEEKMONTHYEARENS 415032005-03-18T19:00:00018 March 2005 19:00:00
[Table view]Other Unspec Reqmnt Other Unspecified Requirement - License Condition 2.C ENS 410102004-09-01T17:50:0001 September 2004 17:50:00 Other Unspec Reqmnt Heat Balance Indication Above Licensed Value ENS 407482004-05-14T12:13:00014 May 2004 12:13:00 Other Unspec Reqmnt Change in the Methodology Used by Ge/Gnf to Demonstrate Compliance with Eccs Performance Requirements 2005-03-18T19:00:00 | |