The following information was provided by the State via email (State text in quotes):
On March 14, 2005 BFI returned a compactor/dumpster to Renaissance Hospital because of radiation detector alarms. After surveying the entire container, one area was reading 9 mR/hr on contact. The trash from this area was again surveyed. A diaper from a patient that had received an I-131 iodine therapy treatment was accidentally put in the regular hospital trash for immediate disposal. The diaper has been removed from the dumpster and sent to the hospital's Nuclear Medicine department for decay. The dumpster was again surveyed after removing the diaper and there were no dose rates above background found. The diaper was reading 10 mR/hr on contact. The diaper was again surveyed on 3/15/05. It was reading 5 mR/hr on contact with a 1 foot reading of 2 mR/hr.
Texas Incident No. I-8220