ENS 41455
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
08:00 Jan 27, 2005 | |
Title | Part 21 Report Concerning Mcpr Limits and Mcpr Monitoring |
Event Description | On 01/27/05, Framatome ANP determined that a deviation exists in the interpolation scheme for the minimum critical power ratio (MCPR) within a range of fuel bundle flows for several operating plants. The condition could be experienced during startup, shutdown, or for other generally very infrequent reasons with core flows in the 30-45% range. The error has no impact on reactor operation above 45% flow. The defect involves the MCPR operating limit and the monitoring of that limit.
The plants where the MCPR operating limit was affected are Browns Ferry Unit 3 and Grand Gulf. The plants where the steady state MCPR predicted by the monitoring system was affected are Browns Ferry Unit 3, Columbia Generating Station, Grand Gulf, LaSalle Unit 2, and River Bend. All affected plants have been notified. Recommendations for compensatory actions have been provided to those plants (Grand Gulf and River Bend) where the impact of the error is evident for current and future cycle exposures. Compensatory measures have been provided to the affected plants for use until the incore monitoring code can be updated at each plant. |
Where | |
---|---|
Framatome Anp Richland Richland, Washington (NRC Region 2) | |
License number: | SNM-1227 |
Reporting | |
10 CFR 21.21 | |
Time - Person (Reporting Time:+820.45 h34.185 days <br />4.884 weeks <br />1.124 months <br />) | |
Opened: | Jerald Holm (Via Fax) 12:27 Mar 2, 2005 |
NRC Officer: | Jeff Rotton |
Last Updated: | Mar 2, 2005 |
41455 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 41455\u003C/a\u003E - \u003Ca href=\"/Framatome_ANP_Richland\" title=\"Framatome ANP Richland\"\u003EFramatome ANP Richland\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EPart 21 Report Concerning Mcpr Limits and Mcpr Monitoring\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 41455 - Framatome ANP Richland\n","link":"","lat":46.35016666666667,"lon":-119.302,"icon":""}],"imageoverlays":null} | |
Framatome ANP Richland with 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation | |
WEEKMONTHYEARENS 421852005-11-15T08:00:00015 November 2005 08:00:00
[Table view]10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 Notification - Safety Limit Minimum Critical Power Ratio Calculation ENS 414552005-01-27T08:00:00027 January 2005 08:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 Report Concerning Mcpr Limits and Mcpr Monitoring 2005-11-15T08:00:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_41455&oldid=1184461"