ENS 41430
ENS Event | |
|---|---|
22:25 Feb 22, 2005 | |
| Title | Report of Missing Special Nuclear Material |
| Event Description | The following details were provided by the licensee via email after the telephonic notification:
This is a non-emergency Event Notification in accordance with 10 CFR 20.2201(a)(1)(ii) to inform the NRC of missing special nuclear material (SNM) (up to approximately 0.15 grams of U235). The missing SNM consists of one complete and three partial in-core detectors. Since June 2004, Pacific Gas and Electric (PG&E) has been performing an investigation and search for three missing 18-inch rod segments at the Humboldt Bay Power Plant (HBPP) (reference NRC Event Notification 40877 and 40963). The investigation also included a verification of the inventory of all SNM, including fuel and non-fuel SNM. As a result of the investigation, plant personnel identified HBPP records that indicate 54 in-core detectors should be in the spent fuel pool (SFP). In-core detectors were used inside in-core assemblies during plant operations to measure reactor power level. There were three in-core detectors contained inside each in-core assembly. The in-core assemblies were segmented for storage, and the in-core detectors from a total of 18 in-core assemblies (containing 54 in-core detectors) should be onsite. Each in-core detector is approximately 2-1/2 inches long. Depending on design, an in-core detector contains as much as 0.04 grams of U235, to slightly less than 0.002 grams of U235. PG&E personnel performed a search in the SFP for the in-core detectors from December 2004 through February 2005. On February 4, 2005, PG&E determined that not all 54 in-core detectors could be located and informed the NRC. PG&E is submitting this Event Notification in accordance with 10 CFR 20.2201(a)(1)(ii) that requires a telephonic report and an Event Notification to be made within 30 days from February 4, 2005. PG&E will be issuing a press release tomorrow that includes this issue. PG&E's search for in-core detectors is complete. PG&E has determined that 50 complete and three partial in-core detectors are in the SFP. Therefore, one complete and three partial in-core detectors are missing. The partial in-core detectors appear to have been cut when the in-core assemblies were cut to be shortened for SFP storage in the mid-1970s or mid-1980s. Most probable locations for the missing in-core detectors are licensed, monitored and restricted radiological control areas, therefore the public health and safety has not been adversely affected. PG&E will issue licensee event report (LER) 2005-001-00, 'Missing In-core Detectors,' dated February 22, 2005, to be submitted in accordance with 10 CFR 20.2201(b)(2)(ii) (Reference PG&E Letter HBL-05-002). Information pertaining to the missing in-core detectors is also included in the HBPP SNM Control and Accountability Project Interim Reports, to be submitted February 22, 2005 (Reference PG&E Letter HBL-05-001). NRC personnel at headquarters and in Region IV have been notified of the status of this issue. |
| Where | |
|---|---|
| Humboldt Bay California (NRC Region 4) | |
| Reporting | |
| 10 CFR 20.2201(a)(1)(ii) | |
| Time - Person (Reporting Time:+-5 h-0.208 days <br />-0.0298 weeks <br />-0.00685 months <br />) | |
| Opened: | David Sokolsky 17:25 Feb 22, 2005 |
| NRC Officer: | Steve Sandin |
| Last Updated: | Feb 22, 2005 |
| 41430 - NRC Website
Loading map... | |
Unit 3 | |
|---|---|
| Reactor critical | Not Critical |
| Scram | No |
| Before | Decommissioned (0 %) |
| After | Decommissioned (0 %) |
Humboldt Bay with 10 CFR 20.2201(a)(1)(ii) | |
WEEKMONTHYEARENS 461202010-06-24T19:00:00024 June 2010 19:00:00
[Table view]10 CFR 20.2201(a)(1)(ii) Calibration Source Discovered Missing During Inventory ENS 414302005-02-22T22:25:00022 February 2005 22:25:00 10 CFR 20.2201(a)(1)(ii) Report of Missing Special Nuclear Material ENS 409632004-08-17T15:30:00017 August 2004 15:30:00 10 CFR 20.2201(a)(1)(ii), 10 CFR 74.11(a), 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release "Report of Missing Special Nuclear Material 2010-06-24T19:00:00 | |