Between 1:30 p.m. and 3:30 pm on March 2, 2004, at Vista & McCarran in Reno, Nevada, a Humboldt Scientific Model 5001
moisture density gauge containing 11 millicuries of
Cs-137 and 44 millicuries of Am-241:Be, s/n 1854, was
stolen from the transport vehicle. The employee indicated the chain securing the
gauge to the pickup bed was cut.
The Reno, Nevada Police Department was notified.
- * * UPDATE FROM STATE OF NEVADA TO ABRAMOVITZ ON 07/13/05 @ 14:41 EDT * * *
The State provided the following information via facsimile:
The gauge was found in a remote canyon east of Reno Nevada on July 12, 2005. The Storey County, Nevada sheriff's office contacted the Nevada Radiological Health Section who took possession of the gauge on July 12, 2005, and placed it in locked storage pending fingerprinting by law enforcement and leak testing. The shipping case for the gauge was not found but radiation measurements indicated the source was intact and the gauge appeared to be undamaged.
Gauge serial number is actually 1859, the 1854 serial number listed above was a typographical error.
Nevada event report number NV040001
Notified the R4DO (Spitzberg),
NMSS EO (Miller) and TASDO (Whitney via e-mail).