ENS 40487
ENS Event | |
|---|---|
20:30 Jan 28, 2004 | |
| Title | 24-Hour Condition of License Report Due to Inoperable Division II Control Room Special Filter Train |
| Event Description | While attempting to perform the Control Room Special Filter Train Functional Test for Division ll, the required train flow test conditions could not be established. Investigation revealed that the inlet backdraft damper 2HVC*DMPV93 was latched closed and would not open automatically on a Special Filter Train start.
The damper was found latched closed due to an improperly set spring-loaded 'stop.' As a result, the Division II Control Room Special Filter Train was declared inoperable as of 1530 on 1/28/04. Technical Specification 3.7.2, Condition A was entered which allows 7 days to restore the Division II Control Room Special Filter Train to an operable status. A review of plant computer data and monthly surveillance tests for the Division II Special Filter Train determined that the backdraft damper has been latched closed since October 2003. As a result, the Division Il Control Room Special Filter exceeded Technical Specification 3.7.2 action to restore Control Room Special Filter Train Subsystem to operable within 7 days. This is reportable under 50.73(a)(2)(i)(B) 'Any operation or condition which was prohibited by the plant's Technical Specifications,' and Section 2.F of the Nine Mile Point Operating License. Per Nine Mile Point Operating license, initial notification that the facility is not operated in accordance with the Technical Specifications shall be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to the NRC Operations Center via the Emergency Notification System, with written follow up within 30 days in accordance with 10 CFR 50.73(b), (c), and (e). A repair plan is being prepared with work to commence today (1/29). Following repairs, surveillance testing will be performed to confirm proper operation of the damper. An inspection of the redundant Division I Control Room Special Filter Train damper and review of monthly surveillance tests demonstrated that the latching mechanism does not interfere with the ability of the damper to open as designed. Therefore, operability of the Division I Control Room Special Filter Train has been confirmed. The licensee informed the NRC Resident Inspector. |
| Where | |
|---|---|
| Nine Mile Point New York (NRC Region 1) | |
| Reporting | |
| Other Unspec Reqmnt | |
| Time - Person (Reporting Time:+17.33 h0.722 days <br />0.103 weeks <br />0.0237 months <br />) | |
| Opened: | David Richardson 13:50 Jan 29, 2004 |
| NRC Officer: | Chauncey Gould |
| Last Updated: | Jan 29, 2004 |
| 40487 - NRC Website
Loading map... | |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (97 %) |
| After | Power Operation (97 %) |
WEEKMONTHYEARENS 493862013-09-25T19:30:00025 September 2013 19:30:00
[Table view]Other Unspec Reqmnt Environmental Impact During Service Water Mollusk Biocide Treatment ENS 432862007-01-11T16:11:00011 January 2007 16:11:00 Other Unspec Reqmnt Initiation of Invalid Primary Containment Isolation Signals ENS 423862006-03-03T23:00:0003 March 2006 23:00:00 Other Unspec Reqmnt Reactor Building Ventilation Flowpath Inoperable ENS 415002005-03-17T22:55:00017 March 2005 22:55:00 Other Unspec Reqmnt Other Unspecified Requirement - License Condition 2.F ENS 407492004-05-14T13:17:00014 May 2004 13:17:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Change in the Methodology Used by Ge/Gnf to Demonstrate Compliance with Eccs Performance Requirements ENS 404872004-01-28T20:30:00028 January 2004 20:30:00 Other Unspec Reqmnt 24-Hour Condition of License Report Due to Inoperable Division II Control Room Special Filter Train 2013-09-25T19:30:00 | |