C7 Progress Energy TS 5.6.1 APR 2 9 2004 SERIAL: BSEP 04-0032 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Brunswick Steam Electric Plant, Unit Nos. 1 and 2 Docket Nos. 50-325 and 50-324lLicense Nos. DPR-71 and DPR-62 Occupational Radiation Exposure Report for 2003 Ladies and Gentlemen:

In accordance with Technical Specification 5.6.1 for the Brunswick Steam Electric Plant, Unit Nos. 1 and 2, Carolina Power & Light Company, doing business as Progress Energy Carolinas, Inc., submits the enclosed Occupational Radiation Exposure Report for January 1, 2003, through December 31, 2003. The total person-rem data provided in the report reflects the exposure for personnel receiving greater than 100 millirem per year.

No regulatory commitments are contained in this submittal. Please refer any questions regarding this submittal to Mr. Leonard R. Beller, Supervisor - Licensing(Regulatory Programs, at (910) 457-2073.

Sincerely, C(%n 2&

Edward T. ONeil Manager - Support Services Brunswick Steam Electric Plant MAT/mat

Enclosure:

Occupational Radiation Exposure Report for 2003 Progress Energy Carolinas, Inc.

Brunswick Nuclear Plant P.O.

Box 10429 Southport, NC 28461

Document Control Desk BSEP 04-0032 / Page 2 cc (with enclosure):

U. S. Nuclear Regulatory Commission, Region II ATTN: Mr. Luis A. Reyes, Regional Administrator Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, GA 30303-8931 U. S. Nuclear Regulatory Commission ATrN: Mr. Eugene M. DiPaolo, NRC Senior Resident Inspector 8470 River Road Southport, NC 28461-8869 U. S. Nuclear Regulatory Commission (Electronic Copy Only)

ATTN: Ms. Brenda L. Mozafari (Mail Stop OWFN 8G9) 11555 Rockville Pike Rockville, MD 20852-2738 Ms. Jo A. Sanford Chair - North Carolina Utilities Commnission P.O. Box 29510 Raleigh, NC 27626-0510

BSEP 04-0032 Enclosure Page 1 of 2 OccupiiaTbi diioi pEposure feport wo^

2003 Number of Personnel > 100 mRem e

Total Person-Rem E

Work and Job Function Station Utility Contract Station Utility Contract Reactor Operations & Surveillance Maintenance Personnel 24 0

24 0.853 0.001 0.177 Operating Personnel 55 0

2 8.606 0.000 0.242 Health Physics Personnel 47 4

15 8.208 0.011 0.521 Supervisory Personnel 4

0 0

0.376 0.000 0.000 Engineering Personnel 5

0 2

0.330 0.000 0.329 Routine Maintenance Maintenance Personnel 110 8

154 21.001 0.341 16.581 Operating Personnel 27 0

1 0.650 0.000 0.002 Health Physics Personnel 39 1

13 2.877 0.001 0.598 Supervisory Personnel 8

0 0

0.915 0.000 0.000 Engineering Personnel 24 0

15 1.873 0.012 3.683 Inservice Inspection Maintenance Personnel 0

0 0

0.000 0.000 0.000 Operating Personnel 0

0 0

0.000 0.000 0.000 Health Physics Personnel 0

0 0

0.000 0.000 0.000 Supervisory Personnel 0

0 0

0.000 0.000 0.000 Engineering Personnel 9

0 0

0.342 0.000 0.000 Special Maintenance' Maintenance Personnel 44 1

31 2.321 0.016 1.079 Operating Personnel 1

0 0

0.035 0.000 0.000 Health Physics Personnel 9

0 4

0.251 0.000 0.052 Supervisory Personnel 1

1 0

0.058 0.016 0.000 Engineering Personnel 5

0 1

0.163 0.000 0.003 1 Special Maintenance includes: turbine maintenance performed at power, spent fuel shipping activities, Unit 2 reactor building roof replacement, and other plant design modifications and various other maintenance activities not normally considered routine in nature.

I Ib BSEP 04-0032 Enclosure Page 2 of 2

.Ocupational Radiation Exposure Report for 200 3 Number of Personnel> 100 rmRem j

Total Person-Rem Work and Job Function Station Utility CotatStation Utlity Contract Waste Processing Maintenance Personnel 1

0 0

0.001 0.000 0.000 Operating Personnel 0

0 0

0.000 0.000 0.000 Health Physics Personnel 0

0 0

0.000 0.000 0.000 Supervisory Personnel 0

0 0

0.000 0.000 0.000 Engineering Personnel 0

0 1

0.000 0.000 0.165 Refueling Maintenance Personnel 107 22 245 19.835 5.238 75.741 Operating Personnel 50 0

1 6.349 0.000 0.282 Health Physics Personnel 43 6

32 3.229 1.639 7.078 Supervisory Personnel 7

1 0

0.827 0.718 0.000 Engineering Personnel 27 1

21 4.261 0.094 4.692 Total Maintenance Personnel 286 31 454 44.011 5.596 93.578 Operating Personnel 133 0

4 15.640 0.000 0.526 Health Physics Personnel 138 11 64 14.565 1.651 8.249 Supervisory Personnel 20 2

0 2.176 0.734 0.000 Engineering Personnel 70 1

40 6.969 0.106 8.872 Grand Total 647 45 562 83.361 8.087 111.225 Grand Total (Corrected For TL) Results) 2 88.100 8.547 117.548 2 Correction Factor = 1.056848. The station total thermoluminescent dosimeter (TID) dose, which includes personnel receiving S 100 mRem, for 2003 was 248.577 person-rem or 124.289 person-rem per unit.