Forwards Rept Re Potential Deficiency in NAMCO-supplied Limit Switches
ML20125D686
Person / Time
Site: Grand Gulf  Entergy icon.png
Issue date: 12/18/1979
From: Dale L
MISSISSIPPI POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20125D689 List:
References
AECM-79-143, NUDOCS 8001150419
Download: ML20125D686 (1)


Text

_.

p/ . MISSISSIPPI F OWER & LIGHT COMPANY

[

a G H e lpin g B uild Mis sis.-in.o r P. O, B O X 16 4 0, J A C K S O N. MISSISSIPPI 39205 a noouctio~ o c a.a tu r ~ t December 18, 1979 Of fice of Inspection & Enforcement U. S. Nuclear Regulatory Commission Region Il 101 Marietta Street, N. W., Suite 3100 Atlanta, Georgia 30303 ,

ATTENTION: Mr. J. P. O' Reilly, Director

Dear Mr. O'Reilly:

Sl!BJECT: Grand Gulf Suclear Station File 0260/155 1/15526 Final Report for PRD-79/!4 Per 10 CPR 50.55(e)

AECM-79/143 On September 7, 1979, Mississippi Power & Light Company notified Mr. J. K. Rausch of your office of a potential reportable deficiency re-garding NAMCO supplied limit switches which may not meet the scfety requirements of the original purchase specification. We have completed our evaluation and determined that this condition is not reportable as defined in 10 CFR 50.55(e). Details of our investigation are described in the attached final report.

Yours truly, I ~' b- .l. _ , ,

L. F. Dale "

/ Nuclear Project Manager JRF/JDR:pa Attachment 90023157 cc: Mr. N. L. Stampley bec: Dr. D. C. Gibbs Mr. R. B. McGehee Mr. A. Zaccaria Mr. T. B, Conner Mr. J. N. Ward gpy N49 D. M. Lake Mr. Victor Stello, Jr. , Director 4 E Mr. R. L. Scott Division of Inspection & Enforcement Mr . J . P. McGau gh y , J r .

U. S. Nuclear Regulatory Commission Mr. k. L. Nail Washington, D. C. 20555 Mr. T. E. Reaves i Mr. C. K. McCoy

, File k

80 011 so 4M g, ke o Member Middle South Utilities System

.- -_ _- . . . - .