2CAN040501, Unit 2, Steam Generator Plugged Tube Report
| ML051090243 | |
| Person / Time | |
|---|---|
| Site: | Arkansas Nuclear |
| Issue date: | 04/11/2005 |
| From: | James D Entergy Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 2CAN040501 | |
| Download: ML051090243 (4) | |
Text
Entergy Entergy Operations, Inc.
1448 S R. 333 Russeliville, AR 72802 Tel 501 858 5000 2CAN040501 April 11, 2005 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
Subject:
Steam Generator Plugged Tube Report Arkansas Nuclear One - Unit 2 Docket No. 50-368 License No. NPF-6
Dear Sir or Madam:
Inservice inspections of Arkansas Nuclear One - Unit 2 (ANO-2) Steam Generator (SG) tubes were performed during refueling outage 2R17. Based on the results of the inspections, which were completed on March 27, 2005, a total of 11 tubes were plugged; 4 tubes in SG-A and 7 tubes in SG-B. The attached report provides additional detail regarding the individual tubes that were affected. This report is submitted in accordance with ANO-2 Technical Specification 6.6.7.a.
This correspondence contains no new commitments.
Sincerely,
. James Acti Director, Nuclear Safety Assurance Attachment r 4
9
4.
2CAN040501 Page 2 cc:
Dr. Bruce S. Mallett Regional Administrator U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Arkansas Nuclear One P.O. Box 310 London, AR 72847 U. S. Nuclear Regulatory Commission Attn: Mr. Drew Holland Mail Stop 0-7 D1 Washington, DC 20555-0001
Attachment 2CAN040501 Arkansas Nuclear One - Unit 2 Steam Generator Plugged Tube Report
Attachment to 2CAN040501 Page I of 1 Arkansas Nuclear One Unit Two 2R17 15 Day Pluaged Tube Report Arkansas Nuclear One - Unit Two performed the 2R17 Inservice Inspection of the Steam Generator tubes starting on March 11, 2005. A total of 11 tubes were plugged based on the inspection results; 4 tubes in Steam Generator A and 7 tubes in Steam Generator B.
Table 1 provides the individual tubes and locations of flaws in Steam Generator A and Table 2 provides the individual tubes and locations of flaws in Steam Generator B. The following are the acronyms for the tables:
SVI Single Volumetric Indication PLP Potential Loose Part Table I Steam Generator A Plugged Tubes ROW LINE IND LOCATION 1
70 169 SVI TSH + 0.25 2
72 169 SVI TSH + 0.87 3
71 170 SVI TSH + 0.92 4
135 78 SVI TSC + 0.04 Table 2 Steam Generator B Plugged Tubes ROW LINE IND LOCATION 1
6 97 PLP TSC + 0.19 2
5 98 PLP TSC + 0.13 3
7 98 PLP TSC + 0.15 4
20 173 PLP TSH + 0.11 5
21 172 PLP TSH + 0.13 6
22 173 PLP TSH + 0.09 7
139 120 SVI TSH + 0.10