05000498/FIN-2008003-03
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Conduct Adequate Radiation Surveys in the Pressurizer Cubicle |
Description | The inspectors reviewed a self-revealing noncited violation of 10 CFR 20.1501 because radiation protection staff failed to perform an adequate survey to evaluate and determine the radiological hazards in the pressurizer cubicle on March 31, 2008. Consequently, a workers electronic dosimeter unexpectedly alarmed at 277 millirem per hour after entering the pressurizer cubicle. A chemically induced crud burst occurred in the reactor primary coolant system, which affected the pressurizer radiological conditions. The licensee entered this issue into the corrective action program as Condition Report 08-5399. The finding was greater than minor because it was associated with the Occupational Radiation Safety Cornerstone attribute (exposure control) of Program and Process and affected the cornerstone objective, in that failure to conduct a radiation survey had the potential to increase personnel dose. This occurrence involved a workers unplanned and unintended exposure to radiation. Therefore, using the Occupational Radiation Safety Significance Determination Process, the finding was determined to be of very low safety significance because it was not an as low as is reasonably achievable finding, there was no overexposure or substantial potential for an overexposure, and the ability to assess dose was not compromised. The finding was self-revealing because the licensee was alerted to the elevated pressurizer cubicle dose rates by the alarming electronic dosimeter. Additionally, this finding has human performance crosscutting aspects associated with work practices, because the licensee failed to ensure interdepartmental communication and coordination during the crud burst between radiation protection, chemistry, and operations to assure timely radiation safety information was provided to workers H.3(b) (Section 2OS1) |
Site: | South Texas ![]() |
---|---|
Report | IR 05000498/2008003 Section 2OS1 |
Date counted | Jun 30, 2008 (2008Q2) |
Type: | NCV: Green |
cornerstone | Or Safety |
Identified by: | NRC identified |
Inspection Procedure: | IP 71121.01 |
Inspectors (proximate) | J Dixon B Tharakan R Kopriva Z Dunham S Graves C Johnson L Carson B Tindell M Hayes |
CCA | H.5, Work Management |
INPO aspect | WP.1 |
' | |
Finding - South Texas - IR 05000498/2008003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (South Texas) @ 2008Q2