| | | Reporting criterion |
|---|
| 05000454/LER-1986-001-06, :on 860116,reactor Trip Occurred Due to Ambiguities in Temporary Procedure.Caused by Insufficient Detail in Procedure to Distinguish Between Two Nearly Identical Auto Shunt Trip Test Panels |
- on 860116,reactor Trip Occurred Due to Ambiguities in Temporary Procedure.Caused by Insufficient Detail in Procedure to Distinguish Between Two Nearly Identical Auto Shunt Trip Test Panels
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000455/LER-1986-001, Errata to LER 86-001-00,incorporating Page 4 Inadvertently Omitted from Original LER Re Crosby Relief Valve JO-25WR | Errata to LER 86-001-00,incorporating Page 4 Inadvertently Omitted from Original LER Re Crosby Relief Valve JO-25WR | |
| 05000455/LER-1986-001-11, :on 861120,component Cooling Pumps 2A & 2B Tripped Due to Pressure Spike Caused by Shutdown of Pump 2A. Event Caused by Personnel Error in Setting Relief Valve. Valve Repaired & Reinstalled |
- on 861120,component Cooling Pumps 2A & 2B Tripped Due to Pressure Spike Caused by Shutdown of Pump 2A. Event Caused by Personnel Error in Setting Relief Valve. Valve Repaired & Reinstalled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-002, :on 860126 & 0204,w/plant in Mode 1,process Radiation Monitor OPR31J (Main Control Room Outside Air Intake a) Went Into Interlock Mode Due to Spike on Monitor Iodine Channel.Caused by Bad Component |
- on 860126 & 0204,w/plant in Mode 1,process Radiation Monitor OPR31J (Main Control Room Outside Air Intake a) Went Into Interlock Mode Due to Spike on Monitor Iodine Channel.Caused by Bad Component
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000455/LER-1986-002-10, :on 861122,digital Rod Position Indication & Bank Demand Step Counters Differed by More than 12 Steps, Requiring Opening of Reactor Trip Breakers.Caused by Defective Detector Encoder Card.Card Replaced |
- on 861122,digital Rod Position Indication & Bank Demand Step Counters Differed by More than 12 Steps, Requiring Opening of Reactor Trip Breakers.Caused by Defective Detector Encoder Card.Card Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-002-04, :on 860126 & 0204,control Room Ventilation Actuation Occurred Due to Process Radiation Monitor OPR31J Iodine Channel Spike.Iodine Channel High Voltage Power Supply & Circuit Boards Replaced |
- on 860126 & 0204,control Room Ventilation Actuation Occurred Due to Process Radiation Monitor OPR31J Iodine Channel Spike.Iodine Channel High Voltage Power Supply & Circuit Boards Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000455/LER-1986-003-10, :on 861216,Safety Injection Train 2B Rendered Inoperable by Closed & out-of-svc Safety Injection Pump 2B During Hot Standby (Mode 3).Caused by Cognitive Personnel Error.Mode Change Checklists Revised |
- on 861216,Safety Injection Train 2B Rendered Inoperable by Closed & out-of-svc Safety Injection Pump 2B During Hot Standby (Mode 3).Caused by Cognitive Personnel Error.Mode Change Checklists Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-003-01, :on 860129,reactor Trip & Auxiliary Feedwater Actuation Occurred.Caused by Grounded Conditions on Positive & Negative Poles of 125 Volt Dc Bus.Reservoir Mods & Updates to Filling Procedures Planned |
- on 860129,reactor Trip & Auxiliary Feedwater Actuation Occurred.Caused by Grounded Conditions on Positive & Negative Poles of 125 Volt Dc Bus.Reservoir Mods & Updates to Filling Procedures Planned
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-004-01, :on 860131 & 0205,outside Diameter Auxiliary Bldg Charcoal Booster Fan Automatically Started W/O Proper Signal.Caused by Failure of Westinghouse AR-3 Relay in Fan Breaker Closing Circuitry.Leads Moved |
- on 860131 & 0205,outside Diameter Auxiliary Bldg Charcoal Booster Fan Automatically Started W/O Proper Signal.Caused by Failure of Westinghouse AR-3 Relay in Fan Breaker Closing Circuitry.Leads Moved
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(a)(2)(viii)(8) |
| 05000454/LER-1986-004-03, :on 860131 & 0205,auxiliary Charcoal Booster Fan Automatically Started W/O Receipt of Valid Start Signal. Caused by Failure of Westinghouse AR-3 Relay in Fan Breaker Closing Circuitry |
- on 860131 & 0205,auxiliary Charcoal Booster Fan Automatically Started W/O Receipt of Valid Start Signal. Caused by Failure of Westinghouse AR-3 Relay in Fan Breaker Closing Circuitry
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000000/LER-1986-005-03, Informs of Planned Site Visit to Obtain Info Supporting Implementation of Emergency Response Data Sys,Including Availability of PWR or BWR Parameters in Digital Form & Characterization of Available Data Feed Points | Informs of Planned Site Visit to Obtain Info Supporting Implementation of Emergency Response Data Sys,Including Availability of PWR or BWR Parameters in Digital Form & Characterization of Available Data Feed Points | |
| 05000454/LER-1986-005-02, :on 860129,loss of Sample Flow Alarm Occurred & on 860130,radioactive Liquid Release Started.Loss of Sample Flow Alarm Due to Sample Pump Seal Failure.Sample Pump Rebuilt |
- on 860129,loss of Sample Flow Alarm Occurred & on 860130,radioactive Liquid Release Started.Loss of Sample Flow Alarm Due to Sample Pump Seal Failure.Sample Pump Rebuilt
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-006-02, :on 860212,control Room Ventilation Sys Train B Shifted to ESF Actuation on Signal from Control Room Air Intake Monitor ORE-PR033.Caused by Procedural Error During Monitor Filter Change.Checklist Implemented |
- on 860212,control Room Ventilation Sys Train B Shifted to ESF Actuation on Signal from Control Room Air Intake Monitor ORE-PR033.Caused by Procedural Error During Monitor Filter Change.Checklist Implemented
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-007, :on 860212,process Radiation Monitor 0PR34J Went Into Interlock Mode Due to Noise Spike on Monitor Gas Channel.Caused by Bad Edge Component or Connector on Motherboard.Motherboard Replaced |
- on 860212,process Radiation Monitor 0PR34J Went Into Interlock Mode Due to Noise Spike on Monitor Gas Channel.Caused by Bad Edge Component or Connector on Motherboard.Motherboard Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-007-02, :on 860212,process Radiation Monitor OPR34J Went Into Interlock Mode Due to Noise Spike on Monitor Gas Channel.Cause of Noise Spike Unknown.Troubleshooting Being Performed to Determine Cause |
- on 860212,process Radiation Monitor OPR34J Went Into Interlock Mode Due to Noise Spike on Monitor Gas Channel.Cause of Noise Spike Unknown.Troubleshooting Being Performed to Determine Cause
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(a)(2)(viii)(8) |
| 05000454/LER-1986-008, :on 860217,turbine Generator & Reactor Trips Occurred Due to Phase Differential Current Sensed by Main Transformer.Caused by Ice Buildup on Transmission Line Tower During Ice Storm.Transformer Replaced |
- on 860217,turbine Generator & Reactor Trips Occurred Due to Phase Differential Current Sensed by Main Transformer.Caused by Ice Buildup on Transmission Line Tower During Ice Storm.Transformer Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000454/LER-1986-009, :on 860222,during Cold Shutdown,Containment Vent Isolation Occurred Due to Undervoltage Condition at Radiation Monitors 1RT-AR011 & 1RT-AR012.Caused by Voltage Transient on 345 Kv Distribution Sys |
- on 860222,during Cold Shutdown,Containment Vent Isolation Occurred Due to Undervoltage Condition at Radiation Monitors 1RT-AR011 & 1RT-AR012.Caused by Voltage Transient on 345 Kv Distribution Sys
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-010-03, :on 860318,w/plant in Mode 1,main Control Room Outside Air Intake B Process Radiation Monitor OPR34J Went Into Interlock Mode Due to Loss of Sample Flow.Caused by Sample Pump Shutdown Due to Bumping Switch |
- on 860318,w/plant in Mode 1,main Control Room Outside Air Intake B Process Radiation Monitor OPR34J Went Into Interlock Mode Due to Loss of Sample Flow.Caused by Sample Pump Shutdown Due to Bumping Switch
| |
| 05000454/LER-1986-011-02, :on 860324,main Control Room Outside Air Intake Process Radiation Monitor B Went Into Interlock Mode Due to High Vacuum Alarm.Caused by Clogged Sample Particulate Filter.Filters on Radiation Monitors Changed |
- on 860324,main Control Room Outside Air Intake Process Radiation Monitor B Went Into Interlock Mode Due to High Vacuum Alarm.Caused by Clogged Sample Particulate Filter.Filters on Radiation Monitors Changed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000454/LER-1986-012-01, :on 860327,RPI Surveillance Not Performed within 4 H.Caused by Personnel Error.Bank Demand Vs Digital RPI Surveillance Reinstated |
- on 860327,RPI Surveillance Not Performed within 4 H.Caused by Personnel Error.Bank Demand Vs Digital RPI Surveillance Reinstated
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-012-02, :on 860327,4 H Surveillance of Digital Rod Position Indication Vs Bank Demand Position Indication Mistakenly Stopped.Caused by Personnel Error.More Specific Instructions on Daily Orders Instituted |
- on 860327,4 H Surveillance of Digital Rod Position Indication Vs Bank Demand Position Indication Mistakenly Stopped.Caused by Personnel Error.More Specific Instructions on Daily Orders Instituted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-013-03, :on 860423,containment Air Lock Leakage Rate Surveillance Performed Late Due to Misapplication of Tech Spec 4.0.2.Caused by Personnel Error.Computer Program Revised to Require Testing Every 6 Months |
- on 860423,containment Air Lock Leakage Rate Surveillance Performed Late Due to Misapplication of Tech Spec 4.0.2.Caused by Personnel Error.Computer Program Revised to Require Testing Every 6 Months
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-014-03, :on 860512,main Control Room Outside Air Intake Process Radiation Monitor a Went Into Interlock Mode.Caused by Clogged Particulate Sample Filter.Filter Interval Changed |
- on 860512,main Control Room Outside Air Intake Process Radiation Monitor a Went Into Interlock Mode.Caused by Clogged Particulate Sample Filter.Filter Interval Changed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000454/LER-1986-015-03, :on 860507,discovered Test Voltage for Verifying Neutron Flux Multiplication for Boron Dilution Protection Sys Incorrect.Caused by Inadequate Procedures. Interim Procedure SPP-86-71 Written |
- on 860507,discovered Test Voltage for Verifying Neutron Flux Multiplication for Boron Dilution Protection Sys Incorrect.Caused by Inadequate Procedures. Interim Procedure SPP-86-71 Written
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(s)(2)(i) |
| 05000454/LER-1986-016-03, :on 860527,following Installation of Backup Electrical Power Supply,Continuous Fire Watch Inadvertently Released from Post.Caused by Personnel Error.Engineer Instructed on Fire Watch Procedures |
- on 860527,following Installation of Backup Electrical Power Supply,Continuous Fire Watch Inadvertently Released from Post.Caused by Personnel Error.Engineer Instructed on Fire Watch Procedures
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-017-03, :on 860602,both Trains of Main Control Room Ventilation Sys Inoperable.Caused by Setpoint Drift on Train a Makeup Fan & Bent Spring Release on Train B Supply Fan Breaker.Setpoint Recalibr & Spring Repaired |
- on 860602,both Trains of Main Control Room Ventilation Sys Inoperable.Caused by Setpoint Drift on Train a Makeup Fan & Bent Spring Release on Train B Supply Fan Breaker.Setpoint Recalibr & Spring Repaired
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-018-03, :on 860602,main Control Room Outside Air Intake Process Radiation Monitor a Went Into Interlock Mode. Caused by Misaligned Check Source Mechanism.Mechanism Realigned |
- on 860602,main Control Room Outside Air Intake Process Radiation Monitor a Went Into Interlock Mode. Caused by Misaligned Check Source Mechanism.Mechanism Realigned
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-019-03, :on 860630,discovered That power-range Nuclear Instrumentation Channel Not Fully Tripped within 6 H of Declaring Channel Inoperable.Caused by Personnel Error. Procedures Revised |
- on 860630,discovered That power-range Nuclear Instrumentation Channel Not Fully Tripped within 6 H of Declaring Channel Inoperable.Caused by Personnel Error. Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-020-02, :on 860702,RCS Leakage Exceeded Tech Specs. Caused by Failed Packing Diaphragms on Isolation Valve. Entire Valve Cut Out & Replaced |
- on 860702,RCS Leakage Exceeded Tech Specs. Caused by Failed Packing Diaphragms on Isolation Valve. Entire Valve Cut Out & Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-021-03, :on 860614,performance of RCS Water Inventory Balance Exceeded Tech Spec Action Statement by 1 H & 27 Minutes.Caused by Personnel Misinterpretation of Requirement.Personnel Counseled |
- on 860614,performance of RCS Water Inventory Balance Exceeded Tech Spec Action Statement by 1 H & 27 Minutes.Caused by Personnel Misinterpretation of Requirement.Personnel Counseled
| |
| 05000454/LER-1986-022-03, :on 860703,during Required Shutdown to Mode 5 Due to Excessive RCS Unidentified Leak,Source Range Nuclear Instrumentation Channels Improperly Declared Operable.Caused by Personnel Error |
- on 860703,during Required Shutdown to Mode 5 Due to Excessive RCS Unidentified Leak,Source Range Nuclear Instrumentation Channels Improperly Declared Operable.Caused by Personnel Error
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-023-03, :on 860718,discovered Installation of Defective Pressurizer Safety Valve as Result of Excessive Seat Leakage on 860717.Caused by Series of Personnel Errors.Secure Storage Cages Constructed |
- on 860718,discovered Installation of Defective Pressurizer Safety Valve as Result of Excessive Seat Leakage on 860717.Caused by Series of Personnel Errors.Secure Storage Cages Constructed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-024-02, :on 860725,w/plant in Power Operation Mode 1, Main Control Room Outside Air Intake a Process Radiation Monitor Went Into Interlock Mode.Caused by Noise Spike on Monitor Particulate Channel |
- on 860725,w/plant in Power Operation Mode 1, Main Control Room Outside Air Intake a Process Radiation Monitor Went Into Interlock Mode.Caused by Noise Spike on Monitor Particulate Channel
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000454/LER-1986-025-02, :on 860826,Tech Spec 3.12.1 Re Radiological Environ Monitoring Not Met.Caused by Personnel Error.Suppl to 1985 Annual Radiological Environ Operating Rept Will Be Submitted |
- on 860826,Tech Spec 3.12.1 Re Radiological Environ Monitoring Not Met.Caused by Personnel Error.Suppl to 1985 Annual Radiological Environ Operating Rept Will Be Submitted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-026-01, :on 860921,actuation of Control Room Ventilation Occurred.Caused by Lightning Strike on Offsite 138 Kv Transmission Line.Mods Installed in 1985 to Reduce Undervoltage Trip Setpoint |
- on 860921,actuation of Control Room Ventilation Occurred.Caused by Lightning Strike on Offsite 138 Kv Transmission Line.Mods Installed in 1985 to Reduce Undervoltage Trip Setpoint
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-027-03, :on 860930,reactor Tripped Following Feedwater Isolation & Turbine Trip Due to Damaged Test Cable.Caused by Personnel Error.Damaged Cable Repaired & Temporary Cable Will Be Installed |
- on 860930,reactor Tripped Following Feedwater Isolation & Turbine Trip Due to Damaged Test Cable.Caused by Personnel Error.Damaged Cable Repaired & Temporary Cable Will Be Installed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-028-02, :on 861002,reactor Manually Tripped.Caused by Defective Firing Card & Intermittent Failure of Alarm Card. Rod Drive Sys Troubleshot,Responsible Circuit Cards Replaced & Alarm Cleared |
- on 861002,reactor Manually Tripped.Caused by Defective Firing Card & Intermittent Failure of Alarm Card. Rod Drive Sys Troubleshot,Responsible Circuit Cards Replaced & Alarm Cleared
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-029-03, :on 861022,480-volt Breaker,Providing Overcurrent Protection for Electrical Penetration Feed to Containment Crane 1HC22G,discovered Not Tested Prior to Entry Into Mode 4.Caused by Personnel Error |
- on 861022,480-volt Breaker,Providing Overcurrent Protection for Electrical Penetration Feed to Containment Crane 1HC22G,discovered Not Tested Prior to Entry Into Mode 4.Caused by Personnel Error
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-030-03, :on 861023,sampling Period for Inoperable Radiation Monitor Delayed for 12 H.Caused by Personnel Error,Memo Issued Reemphasizing Notification Procedures.W/ |
- on 861023,sampling Period for Inoperable Radiation Monitor Delayed for 12 H.Caused by Personnel Error,Memo Issued Reemphasizing Notification Procedures.W/
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-031-03, :on 861121,maint Re Breaking of Nonexempt ASME Code Class 3 Pressure Boundary Strainer Completed & Returned to Svc W/O Required post-maint Visual Exam.Caused by Personnel Error.Visual Exams Performed |
- on 861121,maint Re Breaking of Nonexempt ASME Code Class 3 Pressure Boundary Strainer Completed & Returned to Svc W/O Required post-maint Visual Exam.Caused by Personnel Error.Visual Exams Performed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(a)(1)(1) |
| 05000454/LER-1986-032-02, :on 861208,ESF Response Time Surveillance Discrepancy Noted in Procedure Resulting in Violation of Tech Specs.Caused by Procedure Incorrectly Timing High Steam Pressure Rate Logic Circuitry |
- on 861208,ESF Response Time Surveillance Discrepancy Noted in Procedure Resulting in Violation of Tech Specs.Caused by Procedure Incorrectly Timing High Steam Pressure Rate Logic Circuitry
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-033-03, :on 861209,post-maint Visual Leak Test Not Performed,Violating Tech Spec.Caused by Defective Procedure. Project Const Now Working Under Station Nuclear Work Request Program |
- on 861209,post-maint Visual Leak Test Not Performed,Violating Tech Spec.Caused by Defective Procedure. Project Const Now Working Under Station Nuclear Work Request Program
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-034-03, :on 861212,radiation Detector to Train B Found Defective.Detector Replaced.On 861215,discovered Leads Restored to Wrong Terminals.Caused by Personnel Error. Personnel Counseled |
- on 861212,radiation Detector to Train B Found Defective.Detector Replaced.On 861215,discovered Leads Restored to Wrong Terminals.Caused by Personnel Error. Personnel Counseled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-035, :on 861217,investigation of Possible Part 21 Rept on Cooper Bessemer Ksv Series Emergency Diesel Generators Revealed Nonseismic Switches Had Been Wired Into Engine Overspeed safety-related Trip Circuit |
- on 861217,investigation of Possible Part 21 Rept on Cooper Bessemer Ksv Series Emergency Diesel Generators Revealed Nonseismic Switches Had Been Wired Into Engine Overspeed safety-related Trip Circuit
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000454/LER-1986-035-02, :on 861217,notice Received of Possible Part 21 Rept Re Cooper Bessemer Diesel Generators.Investigation Revealed That non-seismic Switches Wired Into Engine Overspeed.Caused by Design Error |
- on 861217,notice Received of Possible Part 21 Rept Re Cooper Bessemer Diesel Generators.Investigation Revealed That non-seismic Switches Wired Into Engine Overspeed.Caused by Design Error
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |