05000424/LER-2005-004, Manual Reactor Trip Following Main Feed Regulating Valve Failure

From kanterella
(Redirected from 05000424/LER-2005-004)
Jump to navigation Jump to search
Manual Reactor Trip Following Main Feed Regulating Valve Failure
ML053530053
Person / Time
Site: Vogtle 
Issue date: 12/16/2005
From: Grissette D
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-05-2237 LER 05-004-00
Download: ML053530053 (5)


LER-2005-004, Manual Reactor Trip Following Main Feed Regulating Valve Failure
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation
4242005004R00 - NRC Website

text

Southern Nuclear Don E. Grissette Vice President Operating Company, Inc.

40 lnverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.6474 Fax 205.992.0341 December 16, 2005 Docket No.:

50-424 Energy to Serve Your World' NL-05-2237 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Vogtle Electric Generating Plant - Unit 1 Licensee Event Report 1-2005-004 Manual Reactor Trip Following Main Feedwater Regulating Valve Failure Ladies and Gentlemen:

In accordance with the requirements of 10 CFR 50.73, Southern Nuclear Operating Company hereby submits a Vogtle Electric Generating Plant licensee event report for a condition that was determined to be reportable on October 17,2005.

This letter contains no NRC commitments. If you have any questions, please advise.

Sincerely, on E. Grissette Enclosure: LER 1-2005-004 cc:

Southern Nuclear Operating Company Mr. J. T. Gasser, Executive Vice President Mr. T. E. Tynan, General Manager - Plant Vogtle RType: CVC7000 U. S. Nuclear Regulatory Commission Dr. W. D. Travers, Regional Administrator Mr. C. Gratton, NRR Project Manager - Vogtle Mr. G. J. McCoy, Senior Resident Inspector - Vogtle

LICENSEE EVENT REPORT (LER) means used to impose an information (See reverse for required number of y valid OMB control number, the NRC may On October 17,2005, at 1816 EDT, Unit 1 was manually tripped from 100% power due to a rapidly decreasing Steam Generator (SG) #2 water level. The Loop 2 Main Feedwater Regulating Valve (MFRV), 1 FV0520, closed unexpectedly and could not be re-opened from the control room.

A review found that 1FV0520 closed due to an electronic circuit board failure resulting from moisture intrusion into the air operated valve's electro-pneumatic transducer. The transducer was mounted in an inverted manner that did not prevent water ingress and allow drainage. Washdown activities in this area allowed moisture into the transducer, causing the subsequent failure.

The failed transducer was replaced and mounted in the upright configuration. Furthermore, the appropriate procedure has been revised to ensure that electro-pneumatic transducers are mounted in the preferred position, and all washdowns within the power block have been halted until proper administrative controls have been established.

A) REQUIREMENT FOR REPORT 10 CFR 50.73 (a)(2)(iv)(A) requires this report because an unplanned actuation of the reactor protection B) UNIT STATUS AT TIME OF EVENT At the time of this event, Unit 1 was in Mode 1 (Power Operation) at 100% rated thermal power. Other than that described herein, there was no inoperable equipment that contributed to the occurrence of this C) DESCRIPTION OF EVENT On October 17,2005, at 1816 EDT, Unit 1 was manually tripped from 100% power due to a rapidly decreasing Steam Generator (SG) W2 water level. The Loop 2 Main Feedwater Regulating Valve (MFRV), 1FV0520, closed unexpectedly and could not be re-opened from the control room. Another anomaly occurred when, following the reactor trip, operators had to manually close the Loop 1 MFRV, 1FV0510, when it did not close after a feedwater isolation (FWI) signal had been initiated from the reactor trip signal. Auxiliary Feedwater (AFW) actuated as expected to provide water to the SGs and the unit was returned to normal operation in Mode 3 (Hot Standby). The NRC Operations Center was notified of this event on October 17,2005, at 1918 EDT.

A review found that the Loop 2 Main Feedwater Regulating Valve (MFRV), 1FV0520, closed unexpectedly and could not be re-opened due to an electronic circuit board failure resulting from moisture intrusion in this air-operated valve's electro-pneumatic transducer. The transducer, installed in 2003 as a replacement for an obsolete model, was mounted in the inverted position. The vendor manual for the transducer states that it will operate in any position, but should be mounted upright if dust and water ingress effects are to be minimized. Located just outside the North Main Steam Valve Room, the Loop 2 MFRV (and transducer) is under a concrete overhanging roof with one side of the room exposed to the environment. The inverted mounted position exposed a vent in the base assembly of the transducer to the outside environment and was a direct pathway (through screens) to the internal electronics compartment of the body assembly.

Further investigation determined that, prior to the reactor trip, personnel had been cleaning the Main Feedwater Regulating Valve area with a hose and sprayer. Although the washdown was planned, approved, and personnel were mindful of the trip hazard signs, evidence suggests that water from this washdown penetrated through the vent in the tranducer to the electronic circuit board. When the failed (If more space is required, use additional copies of NRC Fom 366A) board revealed material deposits in the area of the vent hole and a burned electrical smell. The inverted mounting of the transducer and the washdown of the area were the causes of the electronics failure, which resulted in a loss of output from the transducer causing the Loop 2 MFRV, 1FV0520, to close.

Following the trip, the Loop 1 MFRV, 1FV0510, had to be manually closed from the control room when it did not close after receiving a feedwater isolation (FWI) signal resulting from the reactor trip. When de-energized, MFRV solenoid valve, 1FY0510A, would not vent out of its exhaust port and therefore had clearly failed to shift to exhaust air from the volume booster and the valve when the FWI signal was present. Testing of this failed solenoid was performed on the bench test and no shuttling of the solenoid valve could be observed with 30 psi pressure and cycling of the electrical source. Therefore, the cause of the MFRV failure to close was binding of this solenoid valve which prevented air from being vented from the MFRV diaphragm. Further internal investigation of the failed solenoid valve will be performed to determine the exact cause for the binding.

D) CAUSE OF EVENT The Loop 2 Main Feedwater Regulating Valve (MFRV), 1FV0520, closed unexpectedly and could not be re-opened due to an electronic circuit board failure resulting from moisture intrusion in this air-operated valve's electro-pneumatic transducer. The transducer, installed in 2003 as a replacement for an obsolete model, was mounted in the inverted position. The inverted mounted position exposed a vent in the base assembly of the transducer to the outside environment and was a direct pathway (through screens) for moisture intrusion into the internal electronics compartment of the body assembly.

E) ANALYSIS OF EVENT Operators responded properly to control feedwater flow and stabilized the unit in Mode 3. Based on these considerations, there was no adverse effect on plant safety or on the health and safety of the public as a result of this event. Operators closed MFXV 1FV0510 after its initial failure to close automatically.

However, the system's safety function had already been completed by the closure of the Loop 1 Main Feedwater Isolation Valve. In addition, the AFW system actuated as designed following initiation of the This event does not represent a safety system functional failure.

F) CORRECTIVE ACTION

1) The failed transducer was replaced and mounted in the upright configuration.
2) Transducers for the remaining three (3) MFRVs in Unit 1 were inspected and were found to be mounted in the upright position. The Unit 2 transducers are of a different design and are not susceptible to this kind of failure.
3) Procedure 22283-C, "Air Operated Valve & Dampers Flowscanner Checkout," has been revised to ensure that electro-pneumatic transducers are mounted in the upright position unless evaluated on a case-by-case basis. These evaluations will consider environmental conditions and the need for housekeeping activities.
4) All washdowns within the power block have been halted until proper administrative controls have been established.

G) ADDITIONAL INFORMATION

1) Failed Components:

I/P Transducer manufactured by Masoneilan International, Inc.

Model #7000.

Solenoid valve manufactured by ASCO Valve Co.

Model #NP832 1 A5E

2) Previous Similar Events:

There have been no previous similar events in the last three years.

3) Energy Industry Identification System Codes:

Main Feedwater System - SJ Auxiliary Feedwater System - BA

4) The MFRV I N 0 5 10 solenoid valve was replaced and the failed solenoid is being sent to the vendor for failure analysis. Additional corrective action will be initiated upon receipt of failure analysis.