| Title | Inoperable \'A\' WRNM Results in a Condition Prohibited by TSs |
| Description | A self-revealing, Green NCV of Unit 3 TS 3.0.4 was identified by the inspectors on January 26, 2009, when a half-scram occurred on Unit 3, shortly after Unit 3 entered Mode 2 for plant startup. Specifically, the A Wide-Range Neutron Monitoring (WRNM) was inoperable as a result of inadequate procedural guidance regarding adjustments made to the mean square voltage (MSV) offset during the outage (prior to the January 26, 2009, startup). The inadequate procedural guidance allowed adjustments to be made which resulted in the WRNM not making a smooth transition from the counting region to the MSV region of operation, causing the AWRNM to be inoperable and resulting in an unexpected half-scram when the WRNM transitioned from the counting region to the MSV region of operation. As a result, TS3.3.1.1 requirements for the number of available channels of WRNM short period RPS trip in Mode 2 had not been met. TS 3.0.4 requires that when a LCO is not met, entry into a mode or other specified condition shall only be made when the associated actions to be entered permit continued operation in the mode or other condition specified for an unlimited period of time. Corrective actions included entering the issue into the CAP, conducting an event review, and submitting a License Event Report (LER) to the NRC, and revising the WRNM adjustment procedure. The finding is more than minor because it is associated with the procedure quality attribute and adversely affected the Initiating Events Cornerstone objective of limiting the likelihood of those events that upset plant stability and challenge critical safety functions. The finding was of very low safety significance because it did not contribute to the likelihood that both a reactor trip would occur and that mitigation equipment would not be available. This finding has a cross-cutting aspect in the area of human performance (resources) because the licensees procedure did not provide adequate guidance to prevent adjusting the MSV offset to an unacceptable value. IMC 0305 aspect: H.2(c |
| Site: | Peach Bottom |
|---|---|
| Report | IR 05000277/2009002 Section 1R15 |
| Date counted | Mar 31, 2009 (2009Q1) |
| Type: | NCV: Green |
| cornerstone | Initiating Events |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | M Brown G Johnson R Fuhrmeister F Bower J Tomlinson P Krohn E Torres |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Peach Bottom - IR 05000277/2009002 | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Peach Bottom) @ 2009Q1
| |||||||||||||||||||||||||||||||||||||