| | Q | CCA | Title |
|---|
| 05000255/FIN-2011016-01 | 2011Q4 | P.5 | Failure to Prevent Recurrence of a Significant Condition Adverse to Quality |
| 05000255/FIN-2011015-02 | 2011Q4 | | Operators did not inform management an at-the-controls reactor operator left the at-the-controls area of the Control Room without providing a turnover to a qualified individual or obtaining permission from the Control Room Supervisor. |
| 05000255/FIN-2011014-09 | 2011Q4 | | Potential Loss of Preferred AC Sources in Harsh Environment |
| 05000255/FIN-2011005-02 | 2011Q4 | H.7 | Failure to Control Packing Configuration of Pressurizer Spray Control Valves |
| 05000255/FIN-2011005-01 | 2011Q4 | H.9 H.2(b) | Failure to Establish Maintenance Procedures For Safety Related Breakers in Pane; D11-2 |
| 05000255/FIN-2011014-01 | 2011Q4 | | Failure to Report a 10 CFR 50.72 Notification for an 8-hour Non-Emergency Report |
| 05000255/FIN-2011014-08 | 2011Q4 | | Failure to Maintain Design and Procurement Control of the 125-Volt DC System |
| 05000255/FIN-2011014-06 | 2011Q4 | | Failure to Establish a Procedure for the Loss of a DC Bus and the Simultaneous Loss of Two Preferred AC Power Sources |
| 05000255/FIN-2011014-02 | 2011Q4 | H.12 | Failure to Have Adequate Work Instructions For Work Performed on Panel D11-2 |
| 05000255/FIN-2011013-01 | 2011Q4 | H.13 | Improper Lubrication of Turbine Driven Auxiliary Feedwater Pump Linkages |
| 05000255/FIN-2011014-03 | 2011Q4 | H.8 | Failure to Implement Human Performance Tools and to Perform an Infrequently Performed Test or Evolution Brief |
| 05000255/FIN-2011014-04 | 2011Q4 | H.9 | Failure to Comply With Work Hour Rules for Non-Covered Workers |
| 05000255/FIN-2011014-05 | 2011Q4 | H.12 | Failure to implement Emergency Operating Procedure Immediate Actions |
| 05000255/FIN-2011014-07 | 2011Q4 | H.14 | Failure to perform an Adequate Operability Evaluation |
| 05000255/FIN-2012002-02 | 2012Q1 | | Potential Exam Compromise During Requalification Exam |
| 05000255/FIN-2012002-01 | 2012Q1 | | Potential Exam Compromise During Requalification Exam |
| 05000255/FIN-2012002-03 | 2012Q1 | P.5 | Intermittent Fuse Contact Causes Feedwater Transient and Plant Trip |
| 05000255/FIN-2012002-04 | 2012Q1 | H.14 | Failure to Ensure Reactor Head Vents Closed During PCS Fill |
| 05000255/FIN-2012002-06 | 2012Q1 | | Corrective Action for Potential Fire-Induced Motor Operated Valve Damage |
| 05000255/FIN-2012003-01 | 2012Q2 | H.2 | Inadequate Design Margins for Evaluation of Leaking SIRWT Nozzles |
| 05000255/FIN-2012003-02 | 2012Q2 | | Operation of Primary Coolant Pumps Outside Design Basis |
| 05000255/FIN-2012003-03 | 2012Q2 | H.2 | Failure to Follow Work Management Process for Reactor Head Work |
| 05000255/FIN-2012004-01 | 2012Q3 | H.14 | Failure to Follow Work Management Processes |
| 05000255/FIN-2012004-02 | 2012Q3 | H.5 | Water Leakage into Control Room during Maintenance |
| 05000255/FIN-2012004-03 | 2012Q3 | H.2 | Foreign Material in SIRWT |
| 05000255/FIN-2012012-01 | 2012Q3 | | TS for PCS Pressure Boundary Leakage |
| 05000255/FIN-2012012-02 | 2012Q3 | | Potential Inadequate Degradation Evaluation of CRDM Housings |
| 05000255/FIN-2012012-03 | 2012Q3 | | Potential Failure to Prevent Recurrence of a Significant Condition Adverse to Quality |