05000250/FIN-2016007-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Provide Adequate Guidance to Prevent LCSWGR Heat-up |
Description | The NRC identified a non-cited violation of Title 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures and Drawings, for the licensees failure to provide adequate procedural guidance to ensure that the temperature in the Load Center Switchgear Room (LCSWGR) remains below the design temperature of 104 F. The licensee entered the issue into the corrective action program and updated the procedure to include a specific guidance to the operator during a loss of air conditioning. This performance deficiency was determined to be more than minor because it was associated with the Procedure Quality attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, failure to provide adequate procedural guidance to prevent operators from opening the east door (el. 18) in the 3A Switchgear Room (SWGR) when the Emergency Diesel Generator (EDG) 3A is operating (i.e., under Loss of Offsite Power conditions) would cause temperatures to rise above the room design temperature of 104 F. The team determined the finding to be of very low safety significance (Green) because the finding was a deficiency affecting the design of a mitigating structure, system, or component (SSC), and the SSC maintained its operability or functionality. This finding was not assigned a cross-cutting aspect because the issue did not reflect present licensee performance. |
Site: | Turkey Point ![]() |
---|---|
Report | IR 05000250/2016007 Section 4OA2 |
Date counted | Sep 30, 2016 (2016Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | B Davis J Rivera N Coovert R Patterson R Taylor |
Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V |
INPO aspect | |
' | |
Finding - Turkey Point - IR 05000250/2016007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Turkey Point) @ 2016Q3
Self-Identified List (Turkey Point)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||