GmU NUCLEAR GPU Nuclear, Inc.
Three Mile Island Nuclear Station Route 441 South Post Office Box 480 Middletown, PA 17057-0480 Tel 717-948-8461 E910-03-039 October 8, 2003 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555
Subject:
Saxton Nuclear Experimental Corporation (SNEC)
Operating Ucense No., DPR-4 Docket No. 50-146 Ucensee Event Report (LER) NO. 2003-002-00, Failure of the Decommissioning Support Facility Alarm Gentlemen, This letter transmits LER No. 2003-002-00, regarding the discovery of a problem with the intrusion alarm on the Saxon Nuclear Experimental Corporation (SNEC) Facility Decommissioning Support Facility.
For a complete description of the event refer to the text of the report provided on the attached NRC Forms 366 and 366A.
This condition did not adversely affect the health and safety of the public. If you have any questions please contact Mr. James J. Byme at (717) 948-8461 eVn Program Director, SNEC cc:
NRC Project Manager NRC Project Scientist, Region 1 1-1-1 a
'J
NRC FOR!M 366 U.S. NUCLEAR REGULATORY COMMISSION Estimated burden per response to comply wit this mandatory Information collection request: 50 hrs. Reported bssons learned are Incorporated Into LICENSEE EVENT REPORT (LER) the Iensfn process and fed back to hIdustry. Forrd comments bwienestknatetotheRecorssMneetBrsnch(T-41F33), U.S. Ndea Rzndtor Conusson ash DC205S0001 and to t P=nra (See reverse for required number of Rtin.Wachbi0toE C 2-andt nd 13dget, dig/characters for each block)
DC 205 nan lfonnation cdlen does not display a dits/characters lor each nock) currntly valid 0MB clnumber, thie NRC may not conduct or sponsor,
~~~~~~~~~~and a person ks not required bo respond to, the infran collection.
FACILITY NAME (1)
DOCKET NUMBER (2)
PAGE 13)
Saxton Nuclear Experimental Corporation Faclity l
05000146 1 OF 4 TnIT 4)
FAILURE OF THE DECOMMISSIONING SUPPORT FACILITY INTRUSION ALARM EVENT DA(J6 l
LER NUMBER 6)
[
REPORT DATE 7)
OTHER FACILITIES INVOLVED (S)
SEQUENTI~l-
~visiot~i FACIJY NAME DOCKEr NUMBER SEQULENTL4L REVISIN MONTH DAY YEAR YEAR NUMBER NUMBER MONTH DAY YEAR
=
FACILTY NAME DOCKET NUMBER 09 10 2003 2003 002 00 10 08 2003 OPERATING ThiS REPORT IS SUBM TTED PURSUANT TO THE REQUIREMENTS OF 10 CFR : (Check eor MreM) 11)
MOD~i9)
N 20.2201 b) 2Q2203(a)(2)(y)
X N.73a)(2))_
50.73(a)2viii)
- - POWER 20.2203(a)(1) 20.2203(aX3)()
50.73(a)(2)(i)
_50.73 a)(29x) 000 20.2203(a)(2Xi)
= 20.2203(a3Mii) 50.73(a)(2)(fii) 73.71 202203(a)(2)(1) 20.2203a)(4) 50.73(a)(2Kiv)
J OTHER 202203(a)(2Kiii) 50.36(c)(1) 50.73(aX2)(v)
Spe In Absac beow or 20.2203(a)(v)
= 50.3(c)(2)
= 50.73(M)(i) h N Form 366A UCENSEE CONTACT FOR THIS LERf2)
NAME TELEPHONE NUMBER Onclude Aea Code)
James J. Byrne lD (717) 948-8461 OC)MPtFTF WF IINF FR F
- - MPN E
F IRFn IN r n RPORT 1
REPORTABLE REPORTABLE
CAUSE
SYSTEM COMPONENT MANUFACTURER TO EPIX
CAUSE
SYSTEM COMPONENT MANUFACTURER TO EPIX A IPPI FFTIRPRT FXPFCTF n 114i EXCPECTED M
lONTH lDAY l YEAR lYES g
l SUBMISSION I
Qffas, ompleteAEXPECTEDTSUBMISSIONDTE).
XJNO DATE (15)
ABSTRACF (Limit to 1400 spaces, i.e., approximately 15 single-spaced typewitten lines) (16)
The Saxton Nuclear Experimental Corporation (SNEC) Facility Is In the final stages of decommissioning. Upon nitial entry into the Decommissioning Support Facility (DSF) on 90103 the Radiological Controls Technician performing the entry noted that the DSF alarm was not armed as required by the SNEC Facility Technical Specifications. Entry into the DSF would allow undeterred entry into the SNEC Facility Containment Vessel.
A single root cause for this event could not be determined. A potential cause was a failure of the responsible Radiological Controls Technician to correctly arm the alarm on 9)9103. To address this possible cause a requirement for a second individual to verify the arming of the ntrusion alarms has been hnstituted. However a separate identical alarm, not required by Technical Specifications, in another area of the facility, which was armed by a different Radiological Controls Technician on 99/03, was also found not to be armed on 9/10/03. This could indicate some failure of the alarm system but testing to date did not entify any deficiencies. However, as the condition of the alarm is suspect the SNEC Facility Exclusion Area has been reduced to the shell of the Containment Vessel as allowed by the SNEC Facility Technical Specifications and the DSF alarrn has been removed from service.
DOCKET LER NUMBER 6 P
SEQUENTIAL REVISION YEAR I NUMBER NUMBER Saxton Nuclear Experimental Corporation Fadlity 05000146 2003 002 00 2
OF 4
L Plant Oferating Conditions Before the Event The Saxton Nuclear Experimental Corp. (SNEC) facility is shutdown, defueled and undergoing decommissioning.
II
Status of Structures, Components, or Systems That Were Inoperable at the Start of the Event and that Contributed to the Event
None.
III
Event Description
Upon initial entry of the Decommissioning Support Facility (DSF) on 9110/03, a Radiological Controls Technician noticed that the DSF alarm System was not armed overnight, when the site was not manned. Entry into the DSF would allow undeterred entry into SNEC Facility Containment Vessel (CV).
This deficiency is a violation of the SNEC Facility Technical Specifications (TS), Section 1.1.3.2 which states the following:
The Containment Vessel (CV) and the Decommissioning Support Facility (DSF) shall be equipped with an intrusion alarm system Intrusion alarms will be activated whenever the site is not manned. Operability shall be verified in accordance with Section 3.5.3. 1.b.
Additionally the same Radiological Controls Technician reported that the Radiological Controls Count Room Trailer alarm was also not armed during the same period. This alarm was set by a different Radiological Controls Technician and is the same type as the DSF alarm but is not required by the SNEC Facility Technical Specifications.
IV Assessment of Safety Conseguences and Implications of the Event There were no safety consequences as a result of the event. There was no evidence of unauthorized entry and no other intrusion alarms were identified during the period that the DSF alarm was not operational.
V Previous Events and Extent of Condition Event Report 2001-01 reported an event in which the Radiological Controls Technician performing the end of the day checklist failed to verify that a door, which would permit access to the CV, was locked. Corrective action implemented for this event was the briefing of all site personnel on the importance of physically verifying that actions are complete. This corrective action was inadequate to prevent recurrence, as it didn't include briefing of new personnel.
LER 2003-001-00 reported an event in which the CV intrusion alarm (LA/XA) for the west CV door had been in an alarm condition for the past several days. A misadjusted alarm switch and the Radiological Controls Technician failure to properly verify its operability with First Energy Dispatch caused this event.
VI Identification of Root Cause No definitive root cause has been determined for this event, however, the following two possible causes have been identified:
DOCKET 2)
LER NUMBER 6i PAGE 3)
I SEQUENTIAL REVISION YEAR I
NUMBER I NUMBER Saxton Nuclear Experimental Corporaion Facility05000146 2003 002 00 3
OF 4
a.
Attention to Detail - The Radiological Controls Technicians may have entered the wrong codes during arming of alarms.
b.
Equipment Failure - Since both the DSF and Count Room Trailer alarms were found unarmed, a system malfumction may have occurred overnight which deactivated the alarms. Two different Radiological Controls Technicians set these alarms as indicated by the End of Day Checklist for 9/09/03. It is considered unlikely that two different Technicians did not adequately set two different alarms on the same evening.
VII
Corrective Actions
Immediate and Short Term:
Attention to Detail The Radiological Controls Technicians who were responsible for closing and locking the DSF and Count Room Trailer on 9/09/03 were interviewed. Both technicians stated that they were sure that the alarm systems were armed when they exited the site. The technicians appeared to have an adequate understanding of how the system is armed and de-armed.
The Radiological Controls Technician who was responsible for opening the DSF and Count Room Trailer on 9/10/03 was also interviewed. The technician stated that he was sure that both alarm systems were not armed when entered. The technician appeared to have an adequate understanding of how the system is armed and de-armed.
The Radiation Safety Officer (RSO) initiated an administrative requirement to have a second individual verify that the CV/DSF intrusion alarms are armed at the end of SNEC operations for the day.
Individuals who have access to the site outside of normal working hours were interviewed to determine if they entered these areas between setting the alarms on 9/9/03 and the initial entry to these areas on 9/10/03. All of these personnel stated that they did not enter the site during this period.
Equipment Failure Nationwide Security was contacted to determine if they received any intrusion alarms between 9/09/03 and 9/10/03 and if an alarm failure was indicated. No alarms were received and the system appeared to be operating satisfactorily (no trouble alarms were indicated) however they have no method of determining whether the alarm was armed. ALSENCO Security was also contacted concerning the possibility of a power failure or other event causing the alarm systems to de-arm. An ALSENCO Security maintenance technician stated that he didn't believe that this was possible but they have had failures due to defective cards. If there is a defect with a card, the alarm system should not be capable of arming.
Testing showed that both the DSF and Count Room alarms are capable of arming and de-arming.
A complete test of the DSF intrusion alarm was conducted on 9/10/03, which included arming and de-arming the system, local and remote alarm verification, and verification of sensors within the DSF. No deficiencies were identified.
Independent testing (i.e., entering a wrong code, arming and de-arming the systems) of the DSF alarm was also conducted by a different individual. The system appears to be operating satisfactorily, but the keypad numbers occasionally stick when they are pressed.
DOCK LER NUMBER 6)
PAGE
)
SEQUENTIAL REVISION YEAR I NBER I NUNBER Saxton Nuclear Expenmental Corporaton Fadlity 05000146 2003 002 00 4
OF 4
As permitted by the SNEC Facility Technical Specifications the Exclusion Area alarm has been moved to the door between the Containment Vessel and the DSF. This change puts the Exclusion Area alarms on a single alarm system monitored by First Energy Dispatch.
Long Term:
Final Status Survey of the SNEC Facility Containment Vessel has recently been completed. Upon NRC acceptance of the results of this survey a pending change to the Technical Specifications will be issued which will eliminate the requirement for an alarmed exclusion area.