05000146/LER-2003-001, Failure to Verify Operability of the Containment Vessel Intrusion Alarm

From kanterella
Jump to navigation Jump to search
Failure to Verify Operability of the Containment Vessel Intrusion Alarm
ML032680713
Person / Time
Site: Saxton File:GPU Nuclear icon.png
Issue date: 09/12/2003
From: Kuehn G
GPU Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
5928-03-20182, E910-03-030 LER 03-001-00
Download: ML032680713 (4)


LER-2003-001, Failure to Verify Operability of the Containment Vessel Intrusion Alarm
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(1)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)

10 CFR 50.73(a)(2)(v), Loss of Safety Function
1462003001R00 - NRC Website

text

GmU NUCLEAR GPU Nuclear, Inc.

Three Mile Island Nuclear Station Route 441 South Post Office Box 480 Middletown, PA 17057.0480 Tel 717-948-8461 5928-03-20182 E910-03-030 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 SAXTON NUCLEAR EXPERIMENTAL CORPORATION (SNEC)

OPERATING LICENSE NO. DPR-4 DOCKET NO. 50-146

SUBJECT:

LICENSEE EVENT REPORT (LER) NO. 2003-001-00 uFAILURE TO VERIFY OPERABILITY OF THE CONTAINMENT VESSEL INTRUSION ALARM" Gentlemen, This letter transmits LER No. 2003-001-00, regarding the discovery of a problem with, and a previous failure to verify, the operability of the intrusion alarm on the Saxton Nuclear Experimental Corporation (SNEC) Facility Containment Vessel.

For a complete description of the event, refer to the text of the report provided on the attached NRC Forms 366 and 366A.

This condition did not adversely affect the health and safety of the public, if you have any questions please contact Mr. James J. Byrne at (717) 948-8461.

Sincerely,

'-Kuehne~~

Program Director, SNEC cc:

NRC Project Manager NRC Project Scientist, Region 1 File No. 03058

.1 Ir

Sep 12 20 04: 16a AmerGen NOB-1 717-948-8185 p. 2 NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION Estimated burden per response to comply with this mandatowy information C011C110 reqest 0 h.

Reorte leaona wedare incorporgted into tfe LICENSEE EVENT REPORT (LER) aridifg p a fed bakdto inds.

ForWard curden e n e R oo ds Managemnert a nh T F33),

(Se. reverse for equired numbero Regi y Commission. Washington DC 2055- 00 and to Fte Pa mo Redg tio Proiect (3150-0104), 6gcs of Mara e ie t an uget (See reemore for required number of Qed.t-Peet(1oaN oo togernt an-dbugt digits/characters fbr each block)

Washington, DC 20503.

If an infomaiaon colecton does not disRmay a

currentl void 0MS contro number, fte NRC mayn o cnd tors no, and a peson is not required to respond to, tm infornin collelon.

FACILITY NAME (it DOCKET NUMBER (2)

PAGE (31

- nTE
4)

Saxton Nuclear Ex erimental CorporationFai 05000146 1 OF 3 liTLE (4 FAILURE TO VERIFY OPERABILITY OF THE CONTAINMENT VESSEL INTRUSION ALARM EVENT DATE (S)

LER NUMBER(S)

REPORT DA 7

OTHER FACILITIES INVOLVED (U)

SEQUENTIAL REVISIO FACLITY NAME DOCKET NUMBER MONTH DAY1YEAR YEA R

NUMBER J MONTH DAY YEAR l

1

~~~~~~~FACI/TwY~

D~E OtCKET NUMBtER 07 18 2003 2003 001 00 09 02 2003 OPERATING THIS REPORT IS SUBMITTE1 PURSUANT TO THE REQUIREMENTS OF 10 CFR 5: (Check ne or more) (11)

MODE (9

)_ _N

_ 20.2201(b) 20.2203(m)(2)(v)

X 50.73(a)(2)(1) 50.73 a)(2 viil POWER

_ 202203(aK1) 202203(a)(3)(i) 50,73(a)(2)(1i) 50.73(a 20x LEVEL (10) l 000 20.2203(a)(2)()

20.2203(a)(3)(iN) 50.73(a)(2)(iii) 73.71 20.2203(a)(2Mii) 20.2203(a)(4) 50.73(a)(2)(1v)

OTHER I _

20.2203(a)(2)(iii) 50.36(c)(1) 50.73(a)(2)(v)

I A"

beow or

. 20.2203(a)(2)iv) 50.36Ic)(2)

- 50.73(a)(2)(viJ

)

FFonm 3WM LICENSEE CONTACT FOR THIS LER 112)

NAE lTELEPHONE NUMBER (Inlude Ar Code)

James J. Byme I

(717) 948-481 f-- "0I CT

_lMP I

- MAD Phru (ywoEflwT Wall lop fPats,3kfI

_l a

l PFP r It%

I IYES (if ye. complete EXPECTED SUBMISSION DATE).

ABSTRACT (Limit to 1400 spaces, i.e., approximately 15 single-spaced typewritten lines) (16)

The Saxton Nuclear Experimental Corporation (SNEC) Facility is in the final stages of decommissioning. Upon closing and securing the containment Vessel (CV) doors on 7/18103 the Radiological Controls Technician responsible for the closure called FirstEnergy Dispatch to verify that the CV Intrusion Alarm was clear. Dispatch reported that the alarm was not clear and it had been in the alarm condition for the past several days. The CV was reentered and, upon inspection, it was discovered that the door was appropriately secured but that the alarm trip switch was not properly set. The switch was reset, verified operable through Dispatch and the CV was secured. The root cause of the event was inadequate training of the technician assigned to perform this task the previous day compounded by Dispatch not reporting to the SNEC Facility that the CV intrusion alarm was In the alarm mode outside of normal working hours. Training has been given to all Radiological Controls Technicians on procedural requirements for opening and closing the CV. Additionally SNEC Management has discussed with FirstEnergy Dispatch the importance and significance of the CV intrusion alarm and notifying SNEC Management if the alarm is in an off-normal condition.

Sep 12 20 04:16a AmerGen NOB-1 717-948-8185 P. 3 DOCKET (2)

LER NUMBER (6)

PAGE (3)

SEQUENTIAL REVI SION YEAR NUMBER NUMBER 50-146 2003 001 00 2

OF 3

I.

Plant ODeratina Conditions Before the Event The Saxton Nuclear Experimental Corp. (SNEC) facility is shutdown, defueled and undergoing decommissioning.

II Status of Structures, Components, or Svstems That Were Inoperable at the Start of the Event and that Contributed to the Event.

None III Event Description Upon closing and securing the Containment Vessel (CV) doors (NIIDR) on 7/18/03 at 1430, the Radiological Controls (Rad Con) Technician responsible for the closure called First Energy Dispatch to verify that the CV intrusion alarm (JA/XA) for the west CV door was clear. The Dispatcher reported that the alarm had not cleared and it had been in an alarm condition for the past several days. Rad Con re-entered the CV and inspected the alarm trip switch and door. The switch was found in the alarm mode position and the door was locked. The switch was immediately re-set, verified operable through the Dispatch, and the CV was adequately secured.

This deficiency is a violation of the SNEC Facility Technical Specifications (TS), Section 1.1.3.2 which states the following:

The Containment Vessel (Ck) and the Decommissioning Support Facility (DSF) shall be equipped with an intrusion alarm system. Intrusion alarms will be activated whenever the site is not manned Operability shall be verified in accordance with Section 3.5.3.1. b.

IV Assessment of Saety Consequences and Implications of the Event There were no safety consequences as a result of the event and the CV west door was verified locked so that inadvertent entry was prevented. Additionally no other intrusion alarms were identified during the period that the CV west door alarm was not operational.

V Previous Events and Extent of Condition Event Report 2001-01 reported an event in which the Radiological Controls Technician performing the end of the day checklist failed to verify that a door, which would permit access to the CV, was locked. Corrective action implemented for this event was the briefing of all site personnel on the importance of physically verifying that actions are complete. This corrective action was inadequate to prevent recurrence, as it didn't include briefing of new personnel.

VI Identification of Root Cause Training - The Rad Con Technician who had been assigned the duty of securing the CV at the end-of-day was a new employee. This individual did not have a clear understanding of the procedural requirements for securing the CV nor did he understand how the alarm system was reset or activated. There is no CV closure-training outline or practical factor sign-off for new Technicians hired at SNEC.

NRC FORM 38OA (5-1ge9)

DOCKET (2)

LER NUMBER (6)

PAGE (3)

SEQUENTIAL I REVISION NUMBER I NUMBER 50-146 2003 001 00 3

OF 3

Low Priority Task - The primary duty of the Dispatch is to control the electrical grid to ensure that customers receive ample electrical power. Dispatch personnel consider SNEC alarm conditions as "low priority" alarms, which sometimes leads to untimely notification and lack of cooperation during surveillance alarm tests and CV closure. The Dispatch should have noticed that the CV intrusion alarm was in the alarm mode outside of normal work hours and telephoned SNEC.

VIII Corrective Actions Immediate and Short Term:

The switch was re-set and verified operable through the Dispatch.

- Training was given to all Rad Con personnel concerning procedural requirements for opening and closing the CV. The SNEC Quality Assurance Officer interviewed several Rad Con Technicians to verify that the training was understood. The Technicians appeared to have an adequate understanding of the requirements.

SNEC Management has briefed FirstEnergy Dispatch on the importance and significance of the CV intrusion alarm.

Long Term:

A CV initial entry and closure training program was developed and given to all Radiological Controls Technicians. The program was also incorporated into the SNEC Rad Con Practical Factors book.

Field training was given to all Radiological Con Technicians and Group Radiological Control Supervisors (GRCS's) concerning CV and DSF alarm system operations. The training included the following:

Activation and deactivation of alarm systems Location of alarm sensors Routine testing of alarms as required by SNEC procedures Documentation