ENS 5559721 November 2021 14:28:00At 1046 EST on November 21, 2021, with Calvert Cliffs Nuclear Power Plant Unit 2 in Mode 1 at 100 percent power, the reactor was manually tripped due to lowering levels in both steam generators following a loss of the 21 and 22 steam generator feed pumps. An Auxiliary Feedwater System actuation occurred to restore steam generator water levels. The trip was not complicated, with all systems responding normally. Decay heat is being removed by the Auxiliary Feedwater System. Calvert Cliffs Nuclear Power Plant Unit 1 is unaffected and remains in Mode 1 at 100 percent power. Due to the Reactor Protection System (RPS) actuation while critical, this event is being reported as a four-hour, non-emergency notification. RPS actuation, per 10 CFR 50.72(b)(2)(iv)(B). Additionally, the automatic actuation of the Auxiliary Feedwater System is being reported as an eight-hour, non-emergency notification, Specific System Actuation, per 10 CFR 50.72(b)(3)(vi)(A). There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified.