Pages that link to "05000373/LER-1983-015, Forwards LER 83-015/03L-0.Detailed Event Analysis Encl"
Jump to navigation
Jump to search
The following pages link to 05000373/LER-1983-015, Forwards LER 83-015/03L-0.Detailed Event Analysis Encl:
Displayed 50 items.
- 05000373/LER-1983-008, Forwards LER 83-008/03L-0 (← links)
- 05000373/LER-1983-004, Forwards LER 83-004/03L-0 (← links)
- 05000373/LER-1983-005, Forwards LER 83-005/01T-0 (← links)
- 05000373/LER-1983-002, Forwards LER 83-002/03L-0 (← links)
- 05000373/LER-1983-022, Forwards LER 83-022/03L-0 (← links)
- 05000373/LER-1983-025, Forwards LER 83-025/03L-0 (← links)
- 05000373/LER-1983-013, Forwards LER 83-013/03L-0 (← links)
- 05000373/LER-1983-011, Forwards LER 83-011/03L-0 (← links)
- 05000373/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000373/LER-1983-117, Updated LER 83-117/03X-1:on 830920 & 30,RHR HX B Outlet Valve Limit Switches Temporarily Changed,Allowing Wedge Travel to Stop (← links)
- 05000373/LER-1983-029, Forwards LER 83-029/03L-0 (← links)
- 05000373/LER-1983-024, Forwards LER 83-024/03L-0 (← links)
- 05000373/LER-1983-023, Forwards LER 83-023/03L-0 (← links)
- 05000373/LER-1983-021, Forwards LER 83-021/01T-0 (← links)
- 05000373/LER-1983-020, Forwards LER 83-020/03L-0 (← links)
- 05000373/LER-1983-016, Forwards LER 83-016/03L-0 (← links)
- 05000373/LER-1983-019, Forwards LER 83-019/03L-0 (← links)
- 05000373/LER-1983-018, Forwards LER 83-018/03L-0 (← links)
- 05000373/LER-1983-017, Forwards LER 83-017/03L-0 (← links)
- ML20072F778 (redirect page) (← links)
- 05000373/LER-1983-015 (redirect page) (← links)
- 05000373/LER-1983-006, Forwards Updated LER 83-006/01X-1 (← links)
- 05000373/LER-1983-001, Forwards LER 83-001/01T-0 (← links)
- 05000373/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000373/LER-1983-026, Forwards LER 83-026/03L-0 (← links)
- 05000373/LER-1983-028, Forwards LER 83-028/03L-0 (← links)
- 05000373/LER-1983-027, Forwards LER 83-027/03L-0 (← links)
- 05000373/LER-1983-030, Forwards LER 83-030/03L-0 (← links)
- 05000373/LER-1983-028-03, /03L-0:on 830320,steam Leak Discovered on Offgas Steam Jet Air Ejector 1A Drain Line to Turbine Bldg Equipment Drains.Caused by Defective Weldment.Work Request L23380 Generated to Repair Weldment (← links)
- 05000373/LER-1983-027-63, /03L-0:on 830320,steam Leak on Main Turbine Control Valve 1 Stem Seal Leakoff Line ITD20AA 1-/2 Inches Discovered.Caused by Overlap of Weldments.Welds Repaired (← links)
- 05000373/LER-1983-030-03, /03L-0:on 830324,local Leak Rate Test on CRD Removal Hatch Double Gasket Seals Incorrectly Performed Prior to Startup.Caused by Personnel Error.Leak Rate Test Reperformed & New Procedure Lts 100-8 Initiated (← links)
- 05000373/LER-1983-057-03, /03L-0:on 830601,following Reactor Scram,Operator Decreased Reactor Pressure to 250 Psig to Allow Condensate Makeup to Reactor to Correct Low RPV Level.Moderator Temp Decreased Faster than Tech Spec Limit in 1 H (← links)
- 05000373/LER-1983-094-03, /03L-0:on 830805,liquid Radwaste Effluent Process Radiation Monitor Declared Inoperable.Caused by Sample Pump Leaking Mechanical Seal.Seal Replaced (← links)
- 05000373/LER-1983-091-03, /03L-0:on 830804,differential Pressure Indicating Switch 1B21-NO37D Hi Switch Setpoint Found Out of Tolerance. Caused by Instrument Drift.Instrument Recalibr (← links)
- 05000373/LER-1983-003-03, /03L-0:on 830118,functional Testing of Condenser Low Vacuum MSIV Isolation Pressure Switches Not Performed for Aug 1982 & Calibr Not Performed for Third Quarter 1982. Caused by Personnel Error.Review of Tech Specs in Progres (← links)
- 05000373/LER-1983-150-01, /01T-0:on 831212,Trip Function 3.a & 4.a for Detector Not Full in Test Not Performed.Caused by Faulty Technique to Identify Requirements.New Procedures Will Be Written to Satisfy Requirements (← links)
- 05000373/LER-1983-153-01, /01T-0:on 831227,OA Diesel Fire Pump Damaged Due to Reverse Rotation.Caused by Wood Block Keeping Oa Diesel Fire Pump Discharge Check Valve Open,Causing Pump & Attached Engine to Rotate Backwards (← links)
- 05000373/LER-1983-151-03, /03L-0:on 831128,Functional Test LIS-NR-02, Required for Operating Conditions 2-5 Due 831125 Not Performed Until 831128.Caused by Personnel Error.Stronger Emphasis on Surveillance Program Implemented (← links)
- 05000373/LER-1983-148-03, /03L-0:on 831118,bus 142Y Deenergized & Switchgear 136X Equipment Failed to Loadshed.Caused by Main Sensing Contact Welding Closed.Contact Separated & Burnished (← links)
- 05000373/LER-1983-152-03, /03L-0:on 831130,shutdown Cooling Inboard Isolation Valve IE12-F009 Exceeded Allowable Leakage Limit. Caused by Bottom Seat Ring Sealing Surface Not Adequately Flat.Ring Machined to Assure Flatness (← links)
- 05000373/LER-1983-149-03, /03L-0:on 831207,setpoint for Reactor Low Water Level Switch 1B21-N024C Exceeded Tech Spec Value.Cause Could Not Be Determined.Switch Immediately Recalibr (← links)
- 05000373/LER-1983-143-01, /01T-0:on 831110,two Cables in Upper Drywell Found Damaged by Heat.Caused by Gaps in Insulation.Insulation Repaired & Inoperable Snubbers Replaced (← links)
- 05000373/LER-1983-145-03, /03L-0:on 831108,during Performance of Tech Spec Required Insps,Setting of Mechanical Snubber NB13-1006S Found Outside of Tolerance.Caused by Excessive Heat in Drywell.Snubber Replaced (← links)
- 05000373/LER-1983-144-03, /03L-0:on 831113,RHR Svc Water Pump 1E12-C300D Would Not Start from Control Room Handswitch,Resulting in auto-trip.Caused by Gummed Up Closing Coil Mechanism for Svc Pump Breaker.Breaker Cleaned (← links)
- 05000373/LER-1983-140-03, /03T-0:on 831123,incorrect Jumper Installation Identified,Preventing Automatic Start of Standby Gas Treatment Sys from Div 1 Initiation Signal.Caused by Jumper Installed on Wrong Panel.Jumper Removed (← links)
- 05000373/LER-1983-139-03, /03L-0:on 831102,two Piping Ys Designed & Installed on Standby Gas Treatment wide-range Sample Sys Suction Piping & Matl,Weld & NDE Documentation Lost.Caused by Personnel Error.Ys Replaced (← links)
- 05000373/LER-1983-138-03, /03L-0:on 831101,air Receiver Pressure for Diesel Generator 2A Dropped Below 200 Psig.Caused by Faulty Hydraulic Unloader Assembly.Compressor Replaced (← links)
- 05000373/LER-1983-141-03, /03L-0:on 831102,offgas Hydrogen Analyzer a Remained in Calibr Mode,Failing Automatic Sampling Sequence. Analyzer B Also Inoperable.Caused by Debris in Filters. Inlet Sample Lines & Filters Cleaned (← links)
- 05000373/LER-1983-142-03, /03L-0:on 831104,RHR Shutdown Cooling Suction Inboard Isolation Valve 2E12-F009 Failed to Open by Motor Operator or Manually.Caused by Closing of Valve When Hot, Resulting in Thermal Stress (← links)
- 05000373/LER-1983-135-03, /03L-0:on 831028,standby Gas Treatment wide-range Gas Monitor Inoperable When Power Lost to Detector Skid OPLD2J.Caused by Powering Up Tritium Sampler.Power Fuse Replaced (← links)