- 05000373/LER-1982-110, Forwards LER 82-110/03L-0 (← links)
- 05000373/LER-1982-099, Forwards LER 82-099/03L-0 (← links)
- 05000373/LER-1982-097, Forwards LER 82-097/03L-0 (← links)
- 05000373/LER-1982-087, Forwards LER 82-087/03L-0 (← links)
- 05000373/LER-1982-107, Forwards LER 82-107/03L-0 (← links)
- 05000373/LER-1982-086, Forwards LER 82-086/03L-0 (← links)
- 05000373/LER-1982-082, Forwards LER 82-082/03L-0 (← links)
- 05000373/LER-1982-076, Forwards LER 82-076/03L-0 (← links)
- ML20063F241 (redirect page) (← links)
- 05000373/LER-1982-077 (redirect page) (← links)
- 05000373/LER-1982-062, Forwards LER 82-062/03L-0 (← links)
- 05000373/LER-1982-044, Forwards LER 82-044/03L-0 (← links)
- 05000373/LER-1982-054, Forwards LER 82-054/03L-0 (← links)
- 05000373/LER-1982-037, Forwards LER 82-037/03L-0 (← links)
- 05000373/LER-1982-061, Forwards LER 82-061/03L-0 (← links)
- 05000373/LER-1982-068, Forwards LER 82-068/03L-0 (← links)
- 05000373/LER-1982-083, Forwards LER 82-083/01T-0 (← links)
- 05000373/LER-1982-074, Forwards LER 82-074/03L-0 (← links)
- 05000373/LER-1982-075, Forwards LER 82-075/03L-0 (← links)
- 05000373/LER-1982-123, Forwards LER 82-123/03L-0 (← links)
- 05000373/LER-1982-132, Forwards LER 82-132/03L-0 (← links)
- 05000373/LER-1982-052, Forwards LER 82-052/03L-0 (← links)
- 05000373/LER-1982-045, Forwards LER 82-045/03L-0 (← links)
- 05000373/LER-1982-053, Forwards LER 82-053/03L-0 (← links)
- 05000373/LER-1982-117-03, /03L-0:on 821008,Div 1 125-volt Dc Battery Charger Failed.Caused by Failure of Amplifier Circuit Board.Bus Crosstied to Unit 2 Supply.Amplifier Board Replaced & Circuit Board Returned to Manufacturer for Repair (← links)
- 05000373/LER-1982-123-03, /03L-0:on 821006,mechanical Snubber HP09-1036S Found Inoperable.Caused by Missing Load Pin Due to Improper Field Installation &/Or Maint Practices.Snubber Repinned (← links)
- 05000373/LER-1982-133-03, /03L-0:on 820930,RHR Svc Water 1C Pump auto-tripped During LOP-RH-09,rendering Pump Inoperable. Caused by Motor Failure Due to Phase to Ground Fault in Motor Field Windings.Motor Replaced (← links)
- 05000373/LER-1982-112-03, /03L-0:on 820929,during Performance of LIS-NB-01, DPIS-1B21-N024D Setpoint for Reactor Vessel Low Water Level Scram Found Out of Calibr.Caused by Instrument Drift.Switch Recalibr.Revision in Progress to Change Tolerance Setp (← links)
- 05000373/LER-1982-121-01, /01T-0:on 821012,found HVAC Duct Hangers S-2065 & S-2049 Not Installed Per Design Drawing.Caused by Inadvertent Substitution of Tube Steel.Design Drawing Will Be Revised (← links)
- 05000373/LER-1982-105-03, /03L-0:on 820920,during LOS-PC-01,valve 1833-F020, Reactor Water Sample Outboard Isolation Valve,Closed Outside Tech Spec Limit.Caused by Spring Tension Not Great Enough to Close Valve.Valve Spring Tightened (← links)
- 05000373/LER-1982-111-03, /03L-0:on 820927,high Airborne Activity Discovered in Radwaste Reboiler Room.Caused by Insufficient Weld Penetration of Tee Between Valves 1B21-F528 & 1B21-F532.Tee Cut Out & Replaced.Reboiler Returned to Svc (← links)
- 05000373/LER-1982-087-03, /03L-0:on 820808,discovered That Source Range Monitor Rod Block Calibr & Functional Test & Intermediate Range Monitor Rod Block & Reactor Scram Calibr & Functional Test Performed 10 Days Apart,Violating Tech Specs (← links)
- 05000373/LER-1982-084-03, /03L-0:on 820806,steam Leak Detected on Body of Main Steam Equalizing Line Downstream Stop Valve.Caused by Crack in Bonnet to Body Seal Weld (Factory Weld).Weld Repaired (← links)
- 05000373/LER-1982-086-03, /03L-0:on 820809,while in Startup Mode at Rated Temp & Pressure (550 F,1,000 Psig),Average Drywell Temp Exceeded 135 F.Caused by Sensible Heat Removal Capability Not Meeting Sensible Heat Load in Drywell (← links)
- 05000373/LER-1982-082-03, /03L-0:on 820731,during Performance of LIS-RH-12, Differential Pressure Switch 1E31-N012A Setpoint Exceeded Allowable Value.Caused by Instrument Setpoint Drift.Trending Underway for Barton Models (← links)
- 05000373/LER-1982-078-03, /03L-0:on 820726,mgt Informed That 820721 Analysis Revealed Snubber RH04-1520S Installed Improperly.Caused by Fillet Weld Overlooked by Production & Qc.Missing Weld Discovered by Design Engineer & Repaired within 30 Days (← links)
- 05000373/LER-1982-069-03, /03L-0:on 820722,drywell Pressure Was - 0.6 Psig Vacuum,Exceeding Tech Spec.Caused by Improperly Installed Steam Traps Downstream of Instrument Nitrogen Compressors. Traps Reinstalled (← links)
- 05000373/LER-1982-077-03, /03L-0:on 820726,reactor Core Isolation Cooling Turbine Inadvertently Rolled.Caused by Unvented Steam in Isolated Section of Steam Piping Due to Closed Check Valve. Limit Switches of Testable Check Valves Adjusted (← links)
- 05000373/LER-1982-061-03, /03L-0:on 820720,RHR B/C Integrity Monitor Alarm Came Up During Heatup.Cause Not Identified.Air Entrapped in Instrument Lines Suspected.Switch Found Satisfactorily Calibr.No Addl Alarms Noted (← links)
- 05000373/LER-1982-064-03, /03L-0:on 820721,position Indication Lights for Automatic Depressurization Sys Valve 1B21-F0134 Failed to Operate,Indicating Valve Open When Observed Closed.Caused by Improper Interaction Between Magnets & Reed Switches (← links)
- 05000373/LER-1982-075-03, /03L-0:on 820726,air Hose to Automatic Dispatch Sys Valve 1B21-FO13V Ruptured So That in Compressors Could Not Maintain Sys Pressure.Probably Caused by Hose Age, Exceeding Min Bend Radius & Exposure to High Temp (← links)
- 05000373/LER-1982-052-03, /03L-0:on 820620,during Routine Surveillance, Instrument Stop Valve for LPCS Pump Discharge Pressure Hi/Lo Switch Found in Lockwired Position.Caused by Improper Return of Switch to Svc.Valve Returned to Svc (← links)
- 05000373/LER-1982-050-03, /03L-0:on 820621,while Shifting from VC Train a to B,Discovered B Train Would Not Maintain Positive Pressure.Caused by Stuck Open Isolation Damper OVC21YA Diverting B Supply Air to a Train (← links)
- 05000373/LER-1982-045-03, /03L-0:on 820615,during Performance of LIS-MS-02, Two Instrument Rack Root Stop Valves Found Closed & Seal Wires Missing.Cause Undetermined.Valves Returned to Open Position & Seal Wired (← links)