- ML20009D597 (redirect page) (← links)
- ML20029B432 (← links)
- ML20009D598 (← links)
- ML20212J915 (← links)
- 05000346/LER-1981-036-03, /03L-0:on 810616,containment Radiation post- Accident monitor,RE-5030,found Not Running.Caused by Low Flow Due to Bypass Discharge Hose Falling Off During Routine Maint.Hose Reconnected & Monitor Restarted (← links)
- 05000346/LER-1981-036, Forwards LER 81-036/03L-0 (← links)
- 05000346/LER-1981-031-03, /03X-1:on 810512,following Reactor Trip,Rcs Radioiodine Content Exceeded Limit.Caused by Gas Leakage Through Fuel Cladding.Levels Decayed Off Below Limits.Tech Spec Revision Being Evaluated (← links)
- 05000346/LER-1981-014-03, /03X-1:on 810226,decay Heat Valve 64 Would Not Open During Testable ECCS Valves Quarterly Test.Caused by Loose Set Rod Bushing,Allowing Gear Box Set Rod to Move Which Unlocked Limit Switches from Adjusted Position (← links)
- 05000346/LER-1981-036 (redirect page) (← links)
- 05000346/LER-1981-035-03, /03T-0:on 810624,concluded That Containment Purge & Exhaust Valves Could Not Be Closed from Open Limit of 65 Degrees During Dba.Caused by Design Deficiency.Mod Will Limit Full Open to 55 Degrees (← links)
- 05000346/LER-1981-035, Forwards LER 81-035/03T-0 (← links)
- 05000346/LER-1981-033-03, /03L-0:on 810604,during Testing,Calibr Zero Gas Ran Out.Caused by Procedural Deficiency.Mod Added to Procedures (← links)
- 05000346/LER-1981-034-03, /03L-0:on 810601,found That When Unit Experienced Power Swing During Turbine Generator Control Valve Test, Main Steam Line Code Safety Valves Lifted Early.Cause Unknown.Investigation Will Be Done in Upcoming Outage (← links)
- 05000346/LER-1981-032-03, /03L-0:on 810604,relay Status Lamp 302A Did Not Change State When Trip Signal Was Applied.Caused by Failed Relay Driver Card in Steam & Feedwater Rupture Control Sys Channel 2.Relay Driver Board Replaced (← links)
- 05000346/LER-1981-032, Forwards LER 81-032/03L-0 (← links)
- 05000346/LER-1981-011-03, /03L-0:on 810205,post-accident Monitoring Instrument HPI Flow 1-2 Was Declared Inoperable.Caused by Bad Current Buffer.Current Buffer Was Repaired,Recalibr & Reinstalled.Hpi Flow 1-2 Was Returned to Operable Status (← links)
- 05000346/LER-1981-011, Forwards LER 81-011/03L-0 (← links)
- 05000346/LER-1981-010, Forwards LER 81-010/03L-0 (← links)
- 05000346/LER-1981-028-03, /03L-0:on 810505,log Review Showed That Liquid Release Had Been Made While Radiation Monitors Re 1878A & B Were Inoperable Due to Testing Date Being Exceeded.Caused by Personnel Error.Personnel Will Be Counseled (← links)
- 05000346/LER-1981-028, Forwards LER 81-028/03L-0 (← links)
- 05000346/LER-1981-027-03, /03L-0:on 810505,flow Indicator Fyi HP3A Found to Be Indicating 380 Gpm W/Pump Off & Valves Closed.Hpi Train 2 Declared Inoperable.Caused by Failure of Buffer Amplifier. Amplifier Repaired (← links)
- 05000346/LER-1981-026-03, /03L-0:on 810428,reactor Protection Sys Channel 1 Tripped on Flux/Delta Flux/Flow.Caused by Failure of Flow Differential Pressure Transmitter Primary Power Transformer Shorting to Ground.New Amplifier Installed & Calibr (← links)
- 05000346/LER-1981-026, Forwards LER 81-026/03L-0 (← links)
- 05000346/LER-1981-025-03, /03L-0:on 810423,during Review of Safety Tagging Log,Unit Entered Mode 4 W/O Required Two Makeup Pumps Operable.Caused by Personnel Error.Pumps Restored to Operation.Personnel Reinstructed in Procedures (← links)
- 05000346/LER-1981-025, Forwards LER 81-025/03L-0 (← links)
- 05000346/LER-1981-021-03, /03L-0:on 810401,half Trip Occurred from Steam & Feedwater Rupture Control Sys Channel 1 Low Steam Generator Level Trip.Caused by Power Supply Failure.Power Supply Replaced Per Work Order on 810402 (← links)
- 05000346/LER-1981-021, Forwards LER 81-021/03L-0 (← links)
- 05000346/LER-1981-020-03, /03L-0:on 810324,valve CV5011A,on Containment Air Sample Inlet Line to Hydrogen Analyzer,Would Not Stroke Closed W/Monitor Operator.Caused by Badly Worn Tripper in Motor Operator.Tripper Levers Replaced (← links)
- 05000346/LER-1981-020, Forwards LER 81-020/03L-0 (← links)
- 05000346/LER-1981-007, Forwards LER 81-007/03L-0 (← links)
- 05000346/LER-1981-004, Forwards LER 81-004/03L-0 (← links)
- 05000346/LER-1981-002-03, /03L-0:on 810102,reactor Coolant Pump 1-2 Was Shutdown Due to High Seal Return Temp & Deteriorating Seal Staging & on 810106,pump 2-1 Was Shutdown for Deteriorating Seal Staging.Caused by Seal Degradation.Seals Replaced (← links)
- 05000346/LER-1981-003-03, /03L-0:on 810106,breaker HX02B Tripped, de-energizing Bus B Which Reduced Electrical Distribution Less than Tech Specs Required.Caused by Personnel Error. Breakers Restored.Operators Counselled Re Attentiveness (← links)
- 05000346/LER-1981-003, Forwards LER 81-003/03L-0 (← links)
- 05000346/LER-1981-001-01, /01T-0:on 810107,analysis Determined That Reportable Condition Had Existed on 801204 When Several Pipe Supports or Fuel Lines to Emergency Diesel Generators Found Disassembled.Caused by Outside Contractor Personnel Error (← links)