Pages that link to "05000327/LER-1982-106, Forwards LER 82-106/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000327/LER-1982-106, Forwards LER 82-106/03L-0:
Displayed 22 items.
- ML20065P614 (← links)
- ML20064D116 (← links)
- ML20070E391 (← links)
- ML20069D708 (redirect page) (← links)
- 05000327/LER-1982-106 (redirect page) (← links)
- 05000327/LER-1982-126, Forwards LER 82-126/01T-0 (← links)
- ML20073B614 (← links)
- 05000327/LER-1982-106-03, /03L-0:on 820821,while in Mode 1 at 100% Power, Axial Flux Difference Discovered to Be Outside Target Band. Caused by Heater Drain Tank Pump Trip Forcing Operators to Reduce Power Manually (← links)
- 05000327/LER-1982-012-03, /03L-0:on 820122,when Divider Barrier Equipment Hatch 3 Was Opened,Seal Gasket Discovered Missing.Probably Caused by Personnel Failure to Verify Gasket Reinstallation on 811016.Gasket Installed.Engineers Reinstructed (← links)
- 05000328/LER-1982-136-03, /03L-0:on 821115,inleakage Found to Be 340 Cubic Ft Per Minute to Annulus During Performance of Surveillance Instruction 264.Caused by Numerous Leaks Found Through Personnel Access & Equipment Doors & Other Areas (← links)
- 05000327/LER-1982-128-01, /01T-0:on 821109,discovered That Suction Damper FCO-31A-14 Had Not Closed Allowing Direct Flow Path to Outside Environ.Caused by Faulty Air Operated Solenoid Valve.Damper Repaired & Operation Verified (← links)
- 05000327/LER-1982-124-03, /03L-0:on 821023 & 28,liquid Radwaste Effluent Line Monitor Failed to Meet Surveillance Requirement.Caused by Contamination Buildup in Sample Chamber.Sample Chamber Cleaned.Procedures Under Review (← links)
- 05000328/LER-1982-122-03, /03L-0:on 821021,during Mode 1 Operation, Pressurizer Pressure Channel 2-PS-68-323B Declared Defective Due to Loss of Ac Power to Channel.Caused by Defective Fuse Holder Cap.Cap Replaced & Channel Returned to Svc (← links)
- 05000327/LER-1982-116-03, /03L-0:on 820916,both Trains of RHR Sys Inoperable Due to Inadvertent Closing of RHR Suction Valve 1-FCV-74-2. Caused by Removal of Power Fuses to Allow Work on Output Relays.Rhr Pump Stopped & Valve Reopened W/Auxiliary Pow (← links)
- 05000328/LER-1982-115-01, /01T-0:on 821002,inner & Outer Doors of Upper Containment Personnel Airlock Were Open Simultaneously Due to Latch Bar Blocking Outer Door Open.Caused by Door Swing Operating Chain Being Out of Adjustment.Chain Adjusted (← links)
- 05000327/LER-1982-112-03, /03L-0:on 820911,upper Head Injection Sys Declared Inoperable Due to Failure to Meet Surveillance Requirements. Caused by Total Dissolved Nitrogen & Air in Accumulator Exceeding 80 Std Cubic Feet Limit (← links)
- 05000328/LER-1982-113-03, /03L-0:on 820910 & 12,upper Head Injection Sys Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Total Dissolved Nitrogen & Air in Accumulator Exceeding 80 Std Cubic Feet Limit (← links)
- 05000327/LER-1982-111-03, /03L-0:on 820903,while in Mode 1,one Containment Pressure Channel for Remote Shutdown Monitoring Instrumentation Failed to Meet Surveillance Requirements. Caused by Closed Sense Line Isolation Valve (← links)
- 05000327/LER-1982-107-01, /01T-0:on 820911,annulus Door (A65) & Access Door (A64) Left Open,Causing Both Trains of Emergency Gas Treatment Sys to Be Declared Inoperable.Caused by Inoperability of Interlocks on Doors (← links)
- 05000327/LER-1982-108-03, /03L-0:on 820907,during Mode 1,level Channel LT-63-50 on Refueling Water Storage Tank Declared Inoperable.Caused by Transmitter Out of Tolerance Due to Instrument Drift.Loop Recalibr (← links)
- 05000328/LER-1982-096-03, /03L-0:on 820720,while in Mode 1,safety Injection Pump Failed to Start W/Handswitch in Start Position.Caused by Improperly Locked Locking Ring on Plug Connector in Back of Handswitch.Connector Cleaned & Reinstalled (← links)
- 05000328/LER-1982-091-03, /03L-0:on 820709,during Performance of SI-166, Upper Limit Switch of Steam Generator Blowdown Containment Isolation Valve 2-FCV-1-7 Found Out of Adjustment.Cause Not Stated.Switch Adjusted (← links)