Pages that link to "05000325/LER-1982-017, Forwards Updated LER 82-017/03L-1"
Jump to navigation
Jump to search
The following pages link to 05000325/LER-1982-017, Forwards Updated LER 82-017/03L-1:
Displayed 50 items.
- 05000325/LER-1982-037, Forwards LER 82-037/03L-0 (← links)
- 05000324/LER-1982-043, Forwards LER 82-043/03L-0 (← links)
- 05000325/LER-1982-017, Forwards LER 82-017/03L-0 (redirect page) (← links)
- 05000325/LER-1982-048, Forwards LER 82-048/03L-0 (← links)
- 05000325/LER-1982-064, Forwards LER 82-064/03L-0 (← links)
- 05000325/LER-1982-063, Forwards LER 82-063/03L-0 (← links)
- 05000325/LER-1982-062, Forwards LER 82-062/03L-0 (← links)
- 05000325/LER-1982-061, Forwards LER 82-061/03L-0 (← links)
- 05000325/LER-1982-052, Forwards LER 82-052/03L-0 (← links)
- 05000325/LER-1982-059, Forwards LER 82-059/03L-0 (← links)
- 05000325/LER-1982-045, Forwards LER 82-045/03L-0 (← links)
- 05000324/LER-1982-077, Forwards LER 82-077/01T-0.Detailed Event Analysis Encl (← links)
- 05000324/LER-1982-080, Forwards LER 82-080/01T-0 (← links)
- 05000325/LER-1982-032, Forwards LER 82-032/03L-0 (← links)
- 05000324/LER-1982-046, Forwards LER 82-046/03L-0 (← links)
- 05000324/LER-1982-045, Forwards LER 82-045/03L-0 (← links)
- 05000325/LER-1982-031, Forwards LER 82-031/03L-0 (← links)
- 05000324/LER-1982-038, Forwards LER 82-038/03L-0 (← links)
- 05000325/LER-1982-035, Forwards LER 82-035/03L-0 (← links)
- 05000324/LER-1982-018, Forwards Updated LER 82-018/03L-1 (← links)
- 05000324/LER-1982-044, Forwards LER 82-044/03L-0 (← links)
- 05000325/LER-1982-034, Forwards LER 82-034/03L-0 (← links)
- 05000325/LER-1982-049, Forwards LER 82-049/03L-0 (← links)
- 05000325/LER-1982-050, Forwards LER 82-050/03L-0 (← links)
- 05000324/LER-1982-059, Forwards LER 82-059/03L-0 (← links)
- 05000325/LER-1982-051, Forwards LER 82-051/03L-0 (← links)
- 05000324/LER-1982-064, Forwards LER 82-064/03L-0 (← links)
- 05000324/LER-1982-113, Forwards LER 82-113/03L-0 (← links)
- 05000324/LER-1982-092, Forwards LER 82-092/03L-0 (← links)
- 05000325/LER-1982-078, Forwards LER 82-078/03L-0 (← links)
- 05000325/LER-1982-079, Forwards LER 82-079/03L-0 (← links)
- 05000324/LER-1982-085, Forwards LER 82-085/01T-0 (← links)
- 05000324/LER-1982-132, Forwards LER 82-132/03L-0 (← links)
- 05000325/LER-1982-151, Forwards LER 82-151/03L-0.Detailed Event Analysis Encl (← links)
- 05000325/LER-1982-131, Forwards LER 82-131/03L-0 (← links)
- 05000325/LER-1982-149, Forwards LER 82-149/01T-0 (← links)
- 05000325/LER-1982-144, Forwards LER 82-144/03L-0 (← links)
- 05000325/LER-1982-127, Updated LER 82-127/01T-1:on 821103,quick Start Testing of Diesel Generators 2,3 & 4 Not Performed for 12 H Period Per Tech Spec.Caused by Failure to Enter Requirement Into Daily Surveillance Rept on 821102.Testing Performed (← links)
- 05000325/LER-1982-142, Forwards LER 82-142/03L-0 (← links)
- 05000325/LER-1982-141, Forwards LER 82-141/03L-0 (← links)
- 05000325/LER-1982-137, Forwards LER 82-137/03L-0 (← links)
- 05000325/LER-1982-133, Forwards LER 82-133/03L-0 (← links)
- 05000325/LER-1982-130, Forwards LER 82-130/03L-0 (← links)
- 05000325/LER-1982-124, Forwards LER 82-124/03L-0 (← links)
- 05000325/LER-1982-129, Forwards LER 82-129/03L-0 (← links)
- 05000324/LER-1982-124, Forwards LER 82-124/01T-0.Detailed Event Analysis Encl (← links)
- 05000325/LER-1982-120, Forwards LER 82-120/03L-0 (← links)
- 05000325/LER-1982-132, Forwards LER 82-132/03L-0 (← links)
- 05000325/LER-1982-128, Forwards LER 82-128/03L-0 (← links)
- 05000325/LER-1982-123, Forwards LER 82-123/03L-0 (← links)
- 05000324/LER-1982-128, Forwards LER 82-128/03L-0 (← links)
- 05000325/LER-1982-117, Forwards LER 82-117/03L-0 (← links)
- 05000324/LER-1982-125, Forwards LER 82-125/03L-0 (← links)
- 05000324/LER-1982-126, Forwards LER 82-126/03L-0 (← links)
- 05000324/LER-1982-106, Forwards LER 82-106/03L-0.Detailed Event Analysis Encl (← links)
- 05000325/LER-1982-089, Forwards LER 82-089/03L-0 (← links)
- 05000325/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000324/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000325/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- ML20069C127 (redirect page) (← links)
- 05000324/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000324/LER-1982-120, Forwards LER 82-120/03L-0 (← links)
- 05000324/LER-1982-130, Forwards LER 82-130/01T-0 (← links)
- 05000324/LER-1982-115, Forwards LER 82-115/03L-0 (← links)
- 05000325/LER-1982-112, Forwards LER 82-112/01T-0 (← links)
- 05000324/LER-1982-105, Forwards LER 82-105/03L-0 (← links)
- 05000324/LER-1982-141, Forwards LER 82-141/03L-0 (← links)
- 05000324/LER-1982-135, Forwards LER 82-135/03L-0 (← links)
- 05000324/LER-1982-143, Forwards LER 82-143/03L-0 (← links)
- 05000325/LER-1982-152, Forwards LER 82-152/03L-0 (← links)
- 05000324/LER-1982-140, Forwards LER 82-140/03L-0 (← links)
- 05000325/LER-1982-140, Forwards LER 82-140/03L-0 (← links)
- 05000325/LER-1982-139, Forwards LER 82-139/03L-0 (← links)
- 05000325/LER-1982-068, Forwards LER 82-068/03L-0 (← links)
- 05000325/LER-1982-057, Forwards LER 82-057/03L-0 (← links)
- 05000325/LER-1982-074, Forwards LER 82-074/03L-0 (← links)
- 05000324/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000325/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000324/LER-1982-014, Forwards LER 82-014/03L-0 (← links)
- 05000324/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000324/LER-1982-107, Forwards Updated LER 82-107/03L-1 (← links)
- 05000324/LER-1982-083, Forwards Updated LER 82-083/03L-1 (← links)
- 05000324/LER-1982-094, Forwards Updated LER 82-094/03L-1 (← links)
- 05000325/LER-1982-066, Forwards LER 82-066/03L-0 (← links)
- 05000325/LER-1982-065, Forwards LER 82-065/03L-0 (← links)
- 05000325/LER-1982-058, Forwards LER 82-058/03L-0 (← links)
- 05000325/LER-1982-014-03, /03L-0:on 820127,post-accident Monitors 2-CAC-AQH-1260-1 & 3 & 1262-1 & 3 Showed Upscale Indications,Along W/Several Unit 1 Monitors.Caused by Moisture Accumulation in Sampling Chanbers.Moisture Removed (← links)
- 05000325/LER-1982-116-03, /03L-0:on 821027,RHR Sys Discharge Valves to Radwaste Sys 1-E11-F040 & F049 Found Not Fully Closed.Cause Under Investigation.Supplemental Rept Outlining Cause & Corrective Actions Will Be Submitted (← links)
- 05000325/LER-1982-111-03, /03L-0:on 821020,PCIV RHR Process Sample Valve 1-E11-F079A Did Not Fully Close on Command.Caused by Mispositioned Unutilized Limit Switch Actuator Arm.Arm Repositioned (← links)
- 05000324/LER-1982-116-03, /03L-0:on 821023,while Performing Control Rod Operability Check,Rod 18-43 Did Not Have RTGB Indication at Position 18.Probably Caused by Defective Rod Position Indication Reed Switch (← links)
- 05000325/LER-1982-114-03, /03L-0:on 821022,comparison of Suppression Chamber Water Level Indications on RTGB Revealed Discrepancy Between Narrow & wide-range Level Instruments.Caused by Valves 1-E11-F040 & F049 Failing to Close Fully.Valves Closed (← links)
- 05000325/LER-1982-127-01, /01T-0:on 821103,quick Start Testing of Diesel Generators 2,3 & 4 Not Performed as Required.Caused by Personnel Not Entering Requirement Into Daily Rept.Personnel Instructed (← links)
- 05000324/LER-1982-120-03, /03L-0:on 821016,suppression Chamber Water Temp Recorder 2-CAC-TR-778 Was Recording Temps Intermittently. Caused by Recorder Print Actuation Solenoid Linkage Being Out of Adjustment.Linkage Adjusted (← links)
- 05000324/LER-1982-130-01, /01T-0:on 821029,during Insp of drywell,through- Wall Linear Indication Discovered at Weld R-20,located on RHR Shutdown Cooling Suction Line Between Line Manual isolation,E11-F067 & Downstream Elbow.Caused by Flaw (← links)
- 05000324/LER-1982-122-03, /03L-0:on 821009,RCIC Sys Automatically Isolated Twice Upon Receipt of Spurious Steam Line Ambient Temp High Signals.Cause Unknown.No Instrumentation Failures Detected. RCIC Sys Returned to Normal Standby Readiness (← links)
- 05000325/LER-1982-112-01, /01T-0:on 821021,during post-maint Testing Preparations on Isolation Valve in Diesel Generator 1 Sprinkler Sys,Continuous Fire Watch Discovered Discontinued Less than 1-h.Caused by Personnel Error (← links)
- 05000324/LER-1982-118-03, /03L-0:on 821006,surveillance Revealed Control Rod 18-23 Had 7 Digit Continuously Lit in Location 1 Regardless of Rod Position.Caused by Defective Rod Position Indication Probe Switch.No Design Mods Planned (← links)
- 05000324/LER-1982-105-03, /03L-0:on 821006,control Rods 18-23 & PT-14.2.1 Exceeded Required 7-s to Fully Insert.Caused by Failure of Rod Hyraulic Control Unit Scram Pilot Valves SV-117 & 118 to Bleed Off Noninterruptible Instrument Air (← links)
- 05000325/LER-1982-001, Forwards Updated LER 82-001/03L-1 (← links)
- 05000324/LER-1982-112-03, /03L-0:on 820929,suppression Chamber Water Temp Recorder 2-CAC-TR-778 Discovered Intermittently Recording Temps on Chart Recorder.Caused by Out of Adjustment Recorder Print Actuation Solenoid.Solenoid Adjusted (← links)
- 05000324/LER-1982-108, Forwards Corrected LER 82-108/03L-0 (← links)
- 05000324/LER-1982-107-03, Review of Fire Protection Carbon Dioxide Sys Surveillance Procedures Indicated Storage Bottle Weighing Device Did Not Have Periodic Calibr.Caused by Failure to Recognize Need for Accuracy Restraints (← links)
- 05000325/LER-1982-081-03, /03L-0:on 820804,during Surveillance Test Requirements Review,Oil Sampling Requirements for Diesel Fuel Oil Sys Not Performed Per ASTM-D270-65.Caused by Absence of Sample Points on Tanks.Tanks Modified (← links)
- 05000324/LER-1982-094-03, Review of Source Range Monitor Sys Channel Functional Test PT-01.2.1 Revealed That Weekly Surveillance During Fuel Handling Did Not Reflect Mode 5 Testing Frequency.Caused by Oversight (← links)
- 05000324/LER-1982-137-03, /03L-0:on 821206,during Operability Test of Remote Shutdown Panel,Rhrsw D/P Transmitter 2-E11-POT-N002BX Did Not Respond to Test Input Signal.Caused by Failed Transmitter Differential Pressure Unit.Transmitter Replaced (← links)
- 05000324/LER-1982-096-03, /03L-0:on 820814,review of Primary Containment Isolation Logic Revealed Failure to Meet Requirement to Have Low Condenser Vacuum Switches B21-PS-N056 (A-D) in Svc When Vessel Pressure Was Greater than or Equal to 500 Psig (← links)
- 05000324/LER-1982-104-03, /03L-0:on 820811,determined That Required Verification of Indicated Power Availability for Specified Plant Dc/Ac Electrical Sys & offsite-onsite Class IE Electrical Sys Was Not Covered in Plant Procedures (← links)
- 05000325/LER-1982-094-03, /03L-0:on 820809,review Revealed Failure of Tech Spec List of Fire Protection Detectors to Reflect Plant Design.Caused by Personnel Failure to Submit Tech Spec Change After Plant Mod Increased Number of Detectors (← links)
- 05000325/LER-1982-085-03, /03L-0:on 820806,discovered Plant Procedures Did Not Provide for Channel Functional Test of Both Unit Aprms for Fixed Neutron Flux High within 24-h of Reactor Starting. Caused by Personnel Oversight.Procedure Revised (← links)
- 05000324/LER-1982-091-03, /03L-0:on 820727,several Relays in Logic Trains for Group 6 Isolation Valves Were Not Time Response Tested as Required.Caused by Personnel Error Due to Inadequate Review of Plant Mods in Jan 1980.Procedures Will Be Revised (← links)
- 05000324/LER-1982-093-03, /03L-0:on 820719,reactor Protective Sys (Rps), Position Switch PT01.3.1PC & Actuation Relay C72-K3A Failed to Actuate.Caused by RPS Logic Wire to Relay Connected to Terminal 17 Instead of 13.Wire Reconnected to Terminal 13 (← links)
- 05000324/LER-1982-089-03, /03L-0:on 820722,review of Plant Maint Procedure Revealed That post-maint Testing of Primary Containment Isolation Valves Per App J Was Not Established.Caused by Administrative Oversight.Procedure Revised (← links)
- 05000324/LER-1982-082-03, /03L-0:on 820722,surveillance Frequency Outlined in Test Procedure PT-01.10 Did Not Reflect Required Weekly Testing While in Operational Mode 5.Caused by Oversight in Development of Test.Periodic Test Revised (← links)
- 05000325/LER-1982-082-03, /03L-0:on 820718,reactor Coolant Chloride Concentration Exceeded Tech Spec Limit.Caused by Leakage of High Chloride Content Main Condenser Cooling Water Into Condensate Sys.Main Condenser Water Box Leaks Repaired (← links)
- 05000325/LER-1982-076-03, /03L-0:on 820719,during Type B & C Low Level Radiation Test on Containment Isolation Equipment,Combined Leak Rate of 11 Primary Containment Valves Exceeded Tech Specs.Caused by Packing & Valve Seat Leaks.Valves Repaired (← links)
- 05000325/LER-1982-084-03, /03L-0:on 820723,review of Procedure for Channel Calibr & Functional Test of Main Steam Line High Flow instrumentation,PT-A20.1,revealed That Refueling Frequency Utilized Vs Required Quarterly Surveillance Frequency (← links)
- 05000324/LER-1982-099-01, /01T-0:on 820731,pneumatic Supply to Cooler Air Operated Fan Exhaust Dampers Found Not to Be safety-grade Air Source,Resulting in Damper Failure During Interruptible Instrument Air Loss.Caused by Design Deficiency (← links)
- 05000324/LER-1982-086-03, /03L-0:on 820715,during Refueling Outage,Source Range Monitors C & D Indicated Erratic Upscale Count Rate. Caused by Guide Tube Sealing Gland Leak Allowing Moisture Intrusion Into Detector Cable Connectors.Leak Repaired (← links)
- 05000325/LER-1982-069-03, /03L-0:on 820715,during Reactor Core Isolation Cooling (RCIC) Sys Operability Test,Rcic Turbine Immediately Tripped Upon Start.Caused by Lack of Common Ref Signal Between Generator & Electronic Governor Module (← links)
- 05000324/LER-1982-087-03, /03L-0:on 820715,during Routine Plant Equipment Surveillance,Fuel Oil Inventory in Diesel Generator 4 Discovered Less than Required.Caused by Bent Guide Assembly Preventing Free Float Movement.Guide Tube Replaced (← links)
- 05000325/LER-1982-067-03, /03L-0:on 820708,primary Containment Atmosphere Oxygen Analyzer 1-CAC-AT-1259-2 Indicated Unexpected Downscale Drywell Oxygen Concentration.Caused by Calibr Shift of Electromagnetic Unit on Zero End.Unit Calibr (← links)
- 05000325/LER-1982-072-03, /03L-0:on 820630,while Investigating Cause of Reactor Scram,Discovered Tech Spec-required Surveillance of Emergency Bus Degraded Voltage & Undervoltage Relays Not Performed.Caused by Personnel Error.Review in Progress (← links)
- 05000324/LER-1982-090-03, /03L-0:on 820704,trip Logic Associated W/Rod Groups 1 & 4 Automatically Reset.Caused by Loose Operator Set Screw in Reactor Scram Reset Switch.Switch Adjusted & Returned to Svc.After Similar 820723 Event,Switch Replaced (← links)
- 05000324/LER-1982-092-03, /03L-0:on 820705,reactor Coolant Chloride Concentration Exceeded Tech Spec Max.Caused by High Chloride Content Water from Suppression Pool.Demineralized Water Added to Vessel Inventory to Reduce Concentration (← links)
- 05000325/LER-1982-079-03, /03L-0:on 820702,RHR Svc Water Pump 1D Tripped During Suppression Pool Cooling.Cause Not Determined. Troubleshooting of Electrical Protective Devices Revealed No Irregularities.Pump Tested & Returned to Svc (← links)
- 05000324/LER-1982-085-01, /01T-0:on 820719,analysis of Bypass Line Around Core Spray Discharge Test Valves E21-F006A & B Determined That Structural Integrity Could Not Be Maintained During Seismic Event.Caused by Const Error.Bypass Lines Removed (← links)
- 05000325/LER-1982-077-03, /03L-0:on 820701,average Power Range Monitor (APRM) F Became Inoperable Due to Upscale Signal from Input Low Power Range Monitor 28-37A While APRM B Also Inoperable. Caused by Moisture in Detector Cable Connector (← links)
- 05000325/LER-1982-058-03, /03L-0:on 820619,routine Surveillance Revealed That Suppression Chamber Water Temp Recorder Was Showing & Recording Normal Temp Indications,But Chart Paper Was Not Advancing.Caused by Broken Tensioning Arm.Arm Repaired (← links)
- 05000325/LER-1982-066-03, /03L-0:on 820619,post-accident Monitoring Control Room Recorder/Indicator 1-CAC-AR-1263,indicated Unexpected Downward Trend in Drywell Oxygen Concentration.Caused by Instrument Shift of Electromagnetic Unit.Unit Recalibr (← links)
- 05000325/LER-1982-065-03, /03L-0:on 820621,primary Containment Atmosphere Oxygen Analyzer 1-CAC-AT-1259-2,indicated Unexpected Upscale Oxygen Concentration in Drywell.Caused by Calibr Shift on Zero End.Electromagnetic Unit Recalibr (← links)
- 05000325/LER-1982-054-03, LER82-054/03L-0:on 820607,reactor Core Isolation Cooling Sys Turbine Automatically Started on Reactor Low Level,But Tripped Due to Closure of Control Valve 1-E51-V9.Caused by Lack of Turbine Speed Demand Signal Due to Govern (← links)
- 05000324/LER-1982-064-03, /03L-0:on 820321,during Performance of Diesel Generator 3 Monthly Load test,PT-12.2C,diesel Tripped & Locked Out Due to Jacket Water Temp Exceeding Trip Setpoint of 200 F.Caused by HX Inlet valve,DJW-V206,being Closed (← links)
- 05000324/LER-1982-079-03, /03L-0:on 820422,primary Containment Atmosphere Hydrogen analyzer,2-CAC-AT-1259-1,indicated Below Scale Hydrogen Concentration in Drywell.Caused by Oxidation of Internals of Potentiometers R3 & R5 (← links)
- 05000324/LER-1982-043-03, /03L-0:on 820323, Tripped/Not Available & Abnormal Condition Annunciators for Diesel Generator 3 Received at Rtgb.Caused by Diesel Barrier Gear Limit Switch Actuating/Initiating Lockout Due to Personnel Error (← links)
- 05000324/LER-1982-076-03, /03L-0:on 820417,CST Suction Low Water Level instrument,2-E41-LSL-N003,did Not Actuate & Repeat within Required Calibr Tolerances.Caused by Organic Deposit within Instrument Float Stem Guide Tube.Deposit Removed (← links)
- 05000324/LER-1982-061, Forwards LER 82-061/03L-0 (← links)
- 05000325/LER-1982-017 (redirect page) (← links)
- 05000324/LER-1982-073-03, /03L-0:on 820414,calibr Check Revealed That Remote Shutdown Instrument Panel 2-CAC-LI-3342 Indicated Incorrect Water Level.Caused by Slight Change in Trickle Flow to Wet Ref Leg of Indicator Transmitter.Transmitter Adjusted (← links)
- 05000325/LER-1982-037-03, /03L-0:on 820317,RTGB Instrument 1-CAC-LR-2602 Indicated Level of -31.2 Inches While RTGB Instrument 1-CAC-LI-2601-3 Read -29.0 Inches.Actual Level -28.5 Inches. Caused by Incorrect Trickle Flow to Transmitter (← links)
- 05000325/LER-1982-046-03, /03L-0:on 820429-0503,while Performing Weekly Verification of Divs I & II 125-volt Ac Battery & Charger Operability PT-17.1P,discovered Specific Gravity for Pilot Cell of Div II Less than Required (← links)
- 05000324/LER-1982-061-03, /03L-0:on 820323,routine Surveillance Revealed That Electrolyte Levels in Cells 34 & 55 of 125-volt Dc Div II Batteries 2B-1 & 2B-2 Were Higher than Max Level Mark. Caused by Overwatering of Cells & Temp Increase (← links)
- 05000324/LER-1982-076, Forwards LER 82-076/03L-0 (← links)
- 05000325/LER-1982-017-03, E11-F048A Valve Had No Indication on RTGB Due to Failure of Valve Breaker Magnetic Trip to Trip Breaker W/Valve in Open Position.Caused by Loose B & C Phase Power Leads to Magnetic Trip Unit (← links)
- 05000324/LER-1982-067, Forwards LER 82-067/03L-0 (← links)
- 05000325/LER-1982-047-03, During RHRSW Operability Test,Vibration of 3.2 Mils Measured for 1B RHRSW Pump.On 820420,during Suppression Cooling,Smoke Observed Emanating from Pump Bearing Housing (← links)
- 05000324/LER-1982-063-03, /03L-0:on 820326,routine Surveillnce Revealed That Primary Containment Atmospheric Oxygen Analyzer 2-CAC-AT-1263-2 Was Not Showing Expected Trend in Drywell Oxygen Concentration.Caused by Stuck Contacts (← links)
- 05000324/LER-1982-056-03, /03L-0:on 820317,during Performance of torus- Reactor Bldg Vacuum Breakers Air Operated Butterfly Valve Actuation Test,Auto Open Actuation Switch of Valve 2-CAC-V16 Failed.Caused by Instrument Drift (← links)
- 05000325/LER-1982-030-03, /03L-0:on 820419,HPCI Steam Line Area High Differential Temp Switch 1-E51-DTS-N604D Would Not Respond to Applied Test Signal.Caused by Electronic Failure of Switch Module.Module 86DT Replaced (← links)
- 05000325/LER-1982-030, Forwards LER 82-030/03L-0 (← links)
- 05000325/LER-1982-038, Forwards LER 82-038/03L-0 (← links)
- 05000324/LER-1982-069-03, /03L-0:on 820424,during Reactor Startup,Rod Overtravel Annunciation Received During Verification of rod-drive Coupling for Rod 30-31.Cause Unknown.Rods Inserted & Deactivated.Rod Will Be Inspected (← links)
- 05000325/LER-1982-022-03, /03L-0:on 820417,reactor Circulation Pump 1A Tripped Due to Motor Generator Set Undervoltage,Resulting from Spurious Opening & Closing of Unit Switchyard Pcb 23A & 23B.Caused by Transmission Line Perturbations (← links)
- 05000325/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000325/LER-1982-042-03, /03L-0:on 820423,post-accident Monitoring Control Room Recorder/Indicator 1-CAC-AR-1263 Exhibited Unvarying Indication of Drywell Oxygen Concentration.Caused by Broken Drive Cord Due to Normal Wear.Drive Cord Replaced (← links)
- 05000324/LER-1982-024, Forwards Updated LER 82-024/03L-2 (← links)
- 05000324/LER-1982-058-03, /03L-0:on 820416,reactor Low Level Switch 2-B21-LIS-N017B-1 Actuated at Lower Simulated Reactor Level than Required.Caused by Instrument Drift of Switch Mechanism & Bad Meter Movement.Instrument Due for Replacement (← links)
- 05000324/LER-1982-058, Forwards LER 82-058/03L-0 (← links)
- 05000324/LER-1982-078, Forwards LER 82-078/03L-0 (← links)
- 05000324/LER-1982-074, Forwards LER 82-074/03L-0 (← links)
- 05000324/LER-1982-048, Forwards LER 82-048/03L-0 (← links)
- 05000324/LER-1982-068, Forwards LER 82-068/03L-0 (← links)
- 05000324/LER-1982-070-03, /03L-0:on 820409,while Performing Plant Mod to Relocate Hydraulic Snubber,Snubber Removed W/O Notifying Operations.Caused by Communications Breakdown Between Const Personnel.Employee Remindend to Follow Required Procedures (← links)
- 05000324/LER-1982-070, Forwards LER 82-070/03L-0 (← links)
- 05000324/LER-1982-075-03, /03L-0:on 820416,during Routine Surveillance, Drywell Floor Drain Flow Integrator 2-G16-FQ-K601 Indicated Continuous Sump Flow W/No Pumps Running.Caused by Operation of Integrator & Square Root Converter Out of Tolerance (← links)
- 05000324/LER-1982-075, Forwards LER 82-075/03L-0 (← links)
- 05000325/LER-1982-043-03, /03L-0:on 820329,exhaust Ventilation Radiation High Instrument 1-D12-RM-N010A Inadvertently Actuated.Caused by Loss of Power Due to Lack of Continuity in Power Supply Output Jumper Plug to Receptacle Connection (← links)
- 05000325/LER-1982-043, Forwards LER 82-043/03L-0 (← links)
- 05000324/LER-1982-060-03, /03L-0:on 820407,specific Gravity for Pilot Cell of Div II Battery 2B-1 Found to Be Less than Required.Cause Could Not Be Determined.Cell Replaced (← links)
- 05000324/LER-1982-060, Forwards LER 82-060/03L-0 (← links)
- 05000325/LER-1982-019-03, /03L-0:on 820415,while Performing Routine Monthly Calibr of RHRSW Suction Header Pressure Switches,B Subsystem Pressure Switch Actuated Intermittently in Response to Applied Test Signal (← links)
- 05000325/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000324/LER-1982-066, Forwards LER 82-066/03L-0 (← links)
- 05000324/LER-1982-065-03, /03L-0:on 820330,during Reactor Core Isolation Sys Isolation Channel Functional & Operability Test,Hpci Sys Automatically Isolated.Caused by Technician Inadvertently Lifting Terminal CC-19 Wire.Wire Reterminated (← links)
- 05000324/LER-1982-065, Forwards LER 82-065/03L-0 (← links)
- 05000325/LER-1982-044-03, /03L-0:on 820329,comparison of RTGB Indications of Suppression Chamber Water Level Revealed Rtbg Instrument 1-CAC-LR-2602 Below Tech Spec.Caused by Change in Trickle Flow to Wet Ref Leg of 2602 Recorder Transmitter (← links)
- 05000324/LER-1982-035-03, /03L-0:on 820330,reactor Core Isolation Cooling Sys Automatically Isolated Due to Receipt of Spurious Steam Leak Detection Differential Temp a Channel Isolation Signal. Cause Unknown.Isolation Signal Reset (← links)
- 05000325/LER-1982-040-03, /03L-0:on 820319,primary Containment Multipoint Temp Recorder 1-CAC-TR-1258 Printed Erratically.Caused by Fouled Electrical Contacts in Recorder Point Select Relay. Contacts Cleaned (← links)
- 05000325/LER-1982-040, Forwards LER 82-040/03L-0 (← links)
- 05000324/LER-1982-054-03, /03L-0:on 820314,reactor Low Level Switch 2-B21-LIS-NO17D-1 Actuated at Level Below Reportable Limit. Caused by Instrument Drift.Switch Recalibr & Returned to Svc (← links)
- 05000324/LER-1982-054, Forwards LER 82-054/03L-0 (← links)
- 05000324/LER-1982-041-03, /03L-0:on 820314,standby Liquid Control Sys Relief Valve 2-C41-FO29A Lifted at Setpoint Exceeding Requirement.Caused by Instrument Drift (← links)
- 05000324/LER-1982-053-03, /03L-0:on 820316,fire Hose Station 2-RB-22 on 20-ft Elevation of Reactor Bldg Found Inoperable Due to Missing Hose Nozzle.Cause of Nozzle Removal Unknown.Nozzle 7160 Replaced.Hose Stations Visually Inspected Monthly (← links)
- 05000324/LER-1982-036-03, /03L-0:on 820314,following Reactor Scram from 57% Power,Reactor Coolant Activity Exceeded Tech Spec Limit of 0.2 Uci/Gm W/Highest Activity at 0.280 Uci/Gm.Caused by Increase in Coolant Fission Inventory from Leaking Fuel (← links)