Pages that link to "05000324/LER-1983-007, Forwards LER 83-007/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000324/LER-1983-007, Forwards LER 83-007/03L-0:
Displayed 50 items.
- 05000324/LER-1983-006, Forwards LER 83-006/03L-0 (← links)
- 05000325/LER-1983-001, Forwards LER 83-001/01T-0 (← links)
- 05000324/LER-1983-004, Forwards LER 83-004/03L-0 (← links)
- 05000324/LER-1983-012, Forwards LER 83-012/03L-0 (← links)
- 05000324/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000325/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000324/LER-1983-013, Forwards LER 83-013/03L-0 (← links)
- 05000324/LER-1983-008, Forwards LER 83-008/03L-0 (← links)
- 05000324/LER-1983-009, Forwards LER 83-009/03L-0 (← links)
- 05000325/LER-1983-002, Forwards LER 83-002/03L-0 (← links)
- 05000325/LER-1983-004, Forwards LER 83-004/01T-0 (← links)
- 05000324/LER-1983-001, Forwards LER 83-001/03L-0 (← links)
- 05000324/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000324/LER-1983-021, Forwards LER 83-021/03L-0 (← links)
- 05000324/LER-1983-014, Forwards LER 83-014/03L-0 (← links)
- 05000324/LER-1983-027, Forwards LER 83-027/03L-0 (← links)
- 05000324/LER-1983-023, Forwards LER 83-023/03L-0 (← links)
- 05000325/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000324/LER-1983-083, Updated LER 83-083/01T-1:on 830905,supply Valve 2-FP-V39 to Deluge Sys of Both Standby Gas Treatment Sys Discovered Shut.Caused by Operator Error.Valves Tagged for Identification.Auxiliary Operator Disciplined (← links)
- 05000325/LER-1983-034, Updated LER 83-034/01T-1:on 830811,following Extended Maint & Refueling Outage,Instrument Isolation Valves to 1CAC-PDS-4222 & 4223 Discovered Closed.Caused by Cancelation of Equipment Clearance.Valves Reopened (← links)
- 05000324/LER-1983-097, Updated LER 83-097/01T-1:on 831212,during Testing,Per IE Bulletin 83-02,crack Indications Discovered in 19 of 131 Welds in Reactor Recirculation & Reactor Water Cleanup Sys. Caused by Stress Corrosion Cracking (← links)
- 05000324/LER-1983-015, Forwards LER 83-015/03L-0 (← links)
- ML20079L172 (redirect page) (← links)
- 05000324/LER-1983-007 (redirect page) (← links)
- 05000325/LER-1983-017, Updated LER 83-017/03L-1:on 830326-28 & 0402,listed Control Rods Had No Indications for Identified Positions.Caused by Loose Prototypic Inlet Piping Connectors Due to Undervessel Work.Connectors Will Be Properly Fastened (← links)
- 05000324/LER-1983-046, Forwards LER 83-046/03L-0 (← links)
- 05000325/LER-1983-014, Forwards LER 83-014/03L-0 (← links)
- ML20073S421 (← links)
- 05000324/LER-1983-016, Forwards LER 83-016/03L-0 (← links)
- 05000324/LER-1983-024, Forwards LER 83-024/03L-0 (← links)
- 05000325/LER-1983-012, Forwards LER 83-012/03L-0 (← links)
- 05000325/LER-1983-015, Forwards LER 83-015/01T-0 (← links)
- 05000324/LER-1983-030, Forwards LER 83-030/03L-0 (← links)
- 05000324/LER-1983-028, Forwards LER 83-028/03L-0 (← links)
- 05000324/LER-1983-033, Forwards LER 83-033/03L-0 (← links)
- 05000324/LER-1983-029, Forwards LER 83-029/03L-0 (← links)
- 05000324/LER-1983-017, Forwards LER 83-017/03L-0 (← links)
- 05000325/LER-1983-006, Forwards Updated LER 83-006/03L-1 (← links)
- 05000324/LER-1983-020, Forwards LER 83-020/03L-0 (← links)
- 05000324/LER-1983-018, Forwards LER 83-018/03L-0 (← links)
- 05000324/LER-1983-042, Forwards LER 83-042/03L-0 (← links)
- 05000324/LER-1983-089-03, /03L-0:on 831010,valve Solenoid Operator Power Supply Fuse FJ-1 Failed,Defeating Valve Capability to Automatically Close on Line Excess Flow.Caused by Water Splashover from Housekeeping Washing (← links)
- 05000325/LER-1983-063-03, Reactor Water Cleanup Sys (Rwcs) Differential Flow Indicator 1-G31-R615 Showed Erroneous Indication.On 831207,spurious Rwcs Alarm Annunciated.Caused by Air in Sensing Lines (← links)
- 05000325/LER-1983-057-03, During Unit Power Performance,Temp Recorder TR-1258 Printed Erratically.Caused by Dirty Electrical Contacts in Control Board Timing Relay. Contacts Cleaned & Returned to Svc (← links)
- 05000325/LER-1983-030-03, /03L-0:on 831221,measured Specific Gravity of Pilot Cell for Div I Battery 1A-1 Found Below Tech Spec Min. Caused by Battery Not Being Fully Charged.Battery Recharged & Surveillance Procedures Revised (← links)
- 05000325/LER-1983-064-03, /03L-0:on 831228,square Root Integrator G16-FYQ-K603 Functioned Out of Calibr Tolerance.Caused by Instrument Drift of FYQ-K603 Square Root Transmitter (SIT) Card.Sit Card Adjusted (← links)
- 05000325/LER-1983-003-03, /03L-0:on 830116,under Reactor Vessel Insp Revealed 17 Low Power Range Monitor Detector Cables Separated from Associated Detectors.Caused by Cables Pulled Loose from Connectors During Maint.Personnel Informed (← links)
- 05000325/LER-1983-055-03, /03L-0:on 831129,reactor Water Sample Outboard Primary Containment Isolation Valve B32-F020 Discovered Not Fully Closed W/Valve Pneumatic Operator.Caused by Actuator Spring Out of Adjustment.Spring Replaced (← links)
- 05000325/LER-1983-062-03, /03L-0:on 831206,exhaust Ventilation Radiation High Instrument 1-D12-RM-N010B Actuated at Setpoint of 13 M/H.Caused by Instrument Setpoint Drift.Adjustments Made (← links)
- 05000325/LER-1983-061-03, /03L-0:on 831127,reactor Power intermediate-range Monitor C51-IRM-K601H Determined Inoperable Due to Downscale Indications.Caused by Signal Preamplifier Low/High Range Gain of K601H Out of Adjustment (← links)