- 05000321/LER-1981-077-03, /03L-0:on 810708,radwaste Loading Dock Discovered Contaminated.Caused by Inadequate Seal Around Shield Doors to Conveyor Aisles,Allowing Resin Containing Waste to Leak Onto Dock (← links)
- 05000321/LER-1981-077, Forwards LER 81-077/03L-0 (← links)
- 05000366/LER-1981-071-03, /03L-0:on 810718,while Performing HNP-2-3111,MSIV D Failed to Close within Required Time Frame.Caused by Low Fluid Level in Hydraulic Operator.Operator Recharged & Filled W/Hydraulic Fluid (← links)
- 05000366/LER-1981-071, Forwards LER 81-071/03L-0 (← links)
- 05000321/LER-1981-081-01, /01T-0:on 810729,w/steady State Operation at 99% Power,Bechtel Determined That RHRSW Piping Intake Structure Was Inadequately Supported.Caused by Inadequate Scsi Design. Addl Supports Have Been Designed & Installed (← links)
- 05000321/LER-1981-081, Forwards LER 81-081/01T-0 (← links)
- 05000321/LER-1981-075, Forwards LER 81-075/03L-0 (← links)
- 05000321/LER-1981-068 (redirect page) (← links)
- 05000321/LER-1981-070-03, /03L-0:on 810723,torus Water Temp Was 97 F.Caused by Continuous Hot Weather Which Increased Temp of Reactor Bldg Environ (← links)
- 05000321/LER-1981-070, Forwards LER 81-070/03L-0 (← links)
- 05000321/LER-1981-067-03, /03L-0:on 810704,discharge Check Valve E11-F005B Failed to Close After Surveillance Procedure.Caused by Excessive Wear at Point Disc Supported by Disc Hanger.Valve Repaired,Sys Retested & Returned to Svc (← links)
- 05000321/LER-1981-058-03, /03L-0:on 810619,drywell 7 Torus Hydrogen & Oxygen Analyzers Were Found Inoperative During Hot Standby. Caused by Instrument Drift.Instruments Recalibr (← links)
- 05000321/LER-1981-058, Forwards LER 81-058/03L-0 (← links)
- 05000321/LER-1981-076-03, /03L-0:on 810708,during Testing,Both Dioxide Analyzers Were Found Reading Lower than Actual Concentration of Oxygen.Caused by Failure of Rochester Current Transmitter in Analyzer a & Calibr Drift in Analyzer B (← links)
- 05000321/LER-1981-076, Forwards LER 81-076/03L-0 (← links)
- 05000321/LER-1981-069, Forwards LER 81-069/03L-0 (← links)
- 05000321/LER-1981-068-03, /03L-0:on 810706,following Reactor Scram,Hpci Sys Auto Initiated,Tripped on High Reactor Water Level,Then Failed to Restart,Due to Failure of Turbine Stop Valve to Open.Caused by Overspeed Trip Sys Malfunction (← links)