- 05000298/LER-1983-001, Forwards LER 83-001/03L-0.Detailed Event Analysis Submitted (← links)
- 05000298/LER-1983-002, Forwards LER 83-002/03L-0.Detailed Event Analysis Submitted (← links)
- 05000298/LER-1983-013, Forwards LER 83-013/03L-0.Detailed Event Analysis Encl (← links)
- ML20073S354 (redirect page) (← links)
- 05000298/LER-1983-003 (redirect page) (← links)
- ML20210K242 (← links)
- 05000298/LER-1983-014-03, /03L-0:on 830915,during Surveillance Testing, Pressurization of Suppression Chamber Air Space Noted During HPCI Turbine Operation.Caused by Error in Vacuum Breaker Design/Installation.Breaker Replaced (← links)
- 05000298/LER-1983-015-03, /03L-0:on 830923,pressure Switch NBI-PS-102A Failed to Perform High Pressure Safety Trip of Reactor Recirculation Pump A.Caused by Relay Failure to Energize. Relay Replaced (← links)
- 05000298/LER-1983-013-03, /03L-0:on 830831,during Local Leak Rate Test, Procedure 6.3.1.1,20,penetrations Found Leaking Excessively. Caused by Discs & Seats Being Lapped.Valves Repaired (← links)
- 05000298/LER-1983-011-01, /01T-0:on 830710,welds CSA-BJ-5 & 6 Found Leaking During Grinding of Weld Crowns.Caused by Intergranular Stress Corrosion Cracking.Welds to Be Repaired by Weld Overlay Methods.Piping Will Be Replaced (← links)
- 05000298/LER-1983-012-03, /03L-0:on 830621,during Control Rod Shuffle,Fuel Bundle Removed & Reloaded Into Core in Same Position W/O All Control Rods Inserted.Caused by Personnel Error.Crews Briefed (← links)
- 05000298/LER-1983-010-03, /03L-0:on 830617,during Functional Surveillance Testing by Wyle Lab,One Main Steam Snubber Failed to Meet Bleed Rate Criteria & One Svc Water Snubber Failed to Meet Lockup Rate.Caused by Plugging by Foreign Matl (← links)
- 05000298/LER-1983-006-03, /03L-0:on 830509,during Performance of Surveillance Procedure 6.3.10.9.1,four RHR Mechanical Snubbers Frozen.Caused by RHR Shutdown Cooling Creating Water Hammer & Overloading snubbers.w/830608 Ltr (← links)
- 05000298/LER-1983-004-03, /03L-0:on 830409,during Sp 6.1.4,contacts of Relay 917-5A-K7D Failed to Open.Cause Not Determined.Relay Coil Replaced & Proper Operation Verified.All Ac Hfa Relays on Essential Sys Will Be Tested During Spring 1983 Outage (← links)
- 05000298/LER-1983-003-03, /03L-0:on 830403,indication & Control Power for Reactor Bldg Exhaust Valve HN-260MV Failed,Resulting in Valve Not Automatically Closing on Isolation Signal.Caused by Burned Out Lamp.Lamp & Fuse Replaced (← links)
- 05000298/LER-1983-009-01, /01T-0:on 830629,pinhole Leaks Found in heat- Affected Zone of Weld CWA-BJ-2 During Insulation Removal on 6-inch Reactor Water Cleanup Suction Line.Caused by Intergranular Stress Corrosion Cracking (← links)
- 05000298/LER-1983-007-03, /03L-0:on 830518,during Refueling,Both Standby Gas Treatment Sys Diesel Generators Found Inoperable.Caused by Personnel Failure to Follow Tech Spec Requirements. Requirements Reviewed & Clarified (← links)
- 05000298/LER-1983-005-03, /03L-0:on 830505,scram Discharge Vol Drain Value CRD-CV-AOV33 Failed to Close Per Tech Specs.Caused by Grafoil Packing Working Between Valve Stem & Body.Valve Repacked (← links)
- 05000298/LER-1983-001-03, /03L-0:on 830223,while Performing Surveillance Procedure 6.2.2.2.4,safety Relief Valve 71-C Failed to Transfer Alternate Power Source When Fuse Pulled.Caused by Bad Contact on Relay.Relay Control Wipe Adjusted (← links)
- 05000298/LER-1983-002-03, /03L-0:on 830218,source Range Monitor Rod Blocks Not Tested Prior to Hot Startup.Caused by Inadequate Procedures.Procedure 2.1.2 Revised (← links)
- 05000298/LER-1983-008-03, /03L-0:on 830530,HFA Relay 9-17-16A K6B Contacts Failed to Open.Cause Not Determined.Relay Coil Replaced. Systematic Replacement of All Relays within 4-yr Period planned.w/830628 Ltr (← links)