The following information was received by email:
On March 6, 2014, UMass Memorial Health Care (license number 60-0096) reported [to the Massachusetts Radiation Control Program] that on March 5, 2014 they had under dosed a patient by more than 20% using Y-90 microspheres. Further pertinent data is:
Prescribed Activity: 26.4 mCi of Y-90 (in one fraction injection)
Delivered Activity: 20.4 mCi of Y-90 (more than 20% different from prescribed)
Resulting in:
Prescribed Liver dose: = 32.6 Gy
Delivered Liver dose: = 25.2 Gy
Dose difference in organ: = 740 rads (i.e., greater than 50 rem and 20% difference)
Note Also:
Effective dose (requested): 32.6 Gy * 0.04 = 1.3 Sv
Effective dose (delivered): 25.2 Gy * 0.04 = 1.0 Sv
Effective dose difference: 1.3-1.0=0.3 Sv = 30 rem (greater than 5 rem difference)
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.