W Progress En'erg Crystal River Nuclear Plant Docket No. -302 OperatingLienseNo. DPR.72 Ref: 10 CFR 50, Appendix E October 28,2003 3F1003-09 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Subject Crystal River Unit 3 - Emergency Response Data System Dear Sir.

The purpose of this letter is to provide a 30 day report to the NRC required by 10CFR50, Appendix E, Section V1.3.a. Software changes were made that affect four (4) transmitted data points identified in the Emergency Response Data System Library for Progress Energy Florida, Inc., Crystal River Unit 3.

Data points P202, P203, P212, and P213 are Nuclear Instrumentation signals for Source Range and Intermediate Range Inputs. They currently display in a linear scale. These data points have been converted from a linear display to a linear exponential display to match the display formatting used for the same points in the Recall/Safety Parameter Display System. The conversion of these points was modified to use a linear exponential conversion. The Minimum Instrument Range, Maximum Instrument Range, Engineering Units Conversion and Plant Specific Point Description fields have been updated to reflect this change. Previously, these points displayed a value that was the exponent to which 10 was to be raised to provide the actual counts per second. This change will now display the actual counts per second.

If you have any questions regarding this submittal, please contact Mr. Sid Powell, Supervisor, Licensing and Regulatory Programs at (352) 5634883.

Sincerely, Donald L Tayl&

Manager, Support Services Crystal River Nuclear Plant DLT/dwh Attachment Revised PWR Data Point Library Reference Files xc:

Regional Administrator, Region II Senior Resident Inspector NRR Project Manager Progress Energy Floda, Inc.

Crystal River Nuclear Plant 15760 W. Powerine Street Crystal River, FL 34428

-AO

CRYSTAL RIVER UNIT 3 DOCKET NUMBER 50 - 302 / LICENSE NUMBER DPR - 72 ATTACHMENT Revised PWR Data Point Library Reference Files

U. S. Nuclear Regulatory Commission 3F1003-09 Attachment Page 1 of 4 Date:

Reactor Unit:

Data Feeder.

NRC ERDS Parameter.

Point ID:

Plant Specific Point

Description:

GenericlCond

Description:

Analog/Digital:

Engineering Units/Digital State:

Engineering Units Conversion:

Minimum Instrument Range:

Maximum Instrument Range:

Zero Point

Reference:

Reference point Notes:

PROC orSENS:

Number of Sensors:

How Processed:

Sensor Locations:

AlannuTrip Setpoints:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-off Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters Level Reference Leg:

Unique System

Description:

FR Data Point Library Reference File 10/24/03 Crystal River Unit 3 N/A NI SOURC RNG P202 Count Rate Channel Ni-I Nuclear Instruments, Source Range A

N/A CPS 0.1 1 E+6 N/A N/A S

I NIA Outside of reactor core but in vicinity N/A 1E-9 Amps 5E-IO Amps Low N/A N/A N/A

U. S. Nuclear Regulatory Commission 3F1003-09 Attachment Page 2 of 4 Date:

Reactor Unit:

Data Feeder.

NRC ERDS Parameter:

Point ID:

Plant Specific Point

Description:

Generic/Cond

Description:

Analog/Digital:

Engineering UnitslDigital State:

Engineering Units Conversion:

Minimum Instrument Range:

Maximum Instrument Range:

Zero Point

Reference:

Reference point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Setpoints:

NI Detector Power Supply Cut-off Power Level:

Ni Detector Power Supply Turn-off Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters Level Reference Leg:

Unique System

Description:

'R Data Point Library Reference File 10/24/03 Crystal River Unit 3 N/A NI SOURC RNG P203 Count Rate Channel NI-2 Nuclear Instruments, Source Range A

N/A CPS 0.1 I E+6 N/A N/A S

I N/A Outside of reactor core but in vicinity N/A IE-9 Amps 5E-10 Amps Low N/A N/A N/A

U. S. Nuclear Regulatory Commission 3F1003-09 Attachment Page 3 of 4 PWR Data Point Library Reference File Date:

10/24/03 Reactor Unit:

Crystal River Unit 3 Data Feeder.

N/A NRC ERDS Parameter.

NI INTER RNG Point ID:

P212 Plant Specific Point

Description:

Channel Ni-3 (AMP)

GenericlCond

Description:

Nuclear Instruments, Intermediate Range Analog/Digital:

A Engineering UnitslDigital State:

N/A Engineering Units Conversion:

Amps Minimum Instrument Range:

1E-11 Maximum Instrument Range:

0.001 Zero Point

Reference:

NIA Reference point Notes:

N/A PROC orSENS:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

Outside of reactor core but in vicinity AlarmlTrip Setpoints:

N/A NI Detector Power Supply Cut-N/A off Power Level:

NI Detector Power Supply Turn-N/A off Power Level:

Instrument Failure Mode:

Low Temperature Compensation for N/A DP Transmitters Level Reference Leg:

N/A Unique System

Description:

NIA

U. S. Nuclear Regulatory Commission 3F1003-09 Attachment Page 4 of 4 PWR Data Point Library Reference File Date:

10/24/03 Reactor Unit:

Crystal River Unit 3 Data Feeder.

NIA NRC ERDS Parameter.

NI INTER RNG Point ID:

P213 Plant Specific Point

Description:

Channel NI-4 (AMP)

Generic/Cond

Description:

Nuclear Instruments, Intermediate Range Analog/Digital:

A Engineering UnitslDigital State:

N/A Engineering Units Conversion:

Amps Minimum Instrument Range:

IE-11 Maximum Instrument Range:

0.001 Zero Point

Reference:

N/A Reference point Notes:

N/A PROC or SENS:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

Outside of reactor core but in vicinity AlarmlTrip Setpoints:

N/A NI Detector Power Supply Cut-N/A off Power Level:

NI Detector Power Supply Turn-N/A off Power Level:

Instrument Failure Mode:

Low Temperature Compensation for N/A DP Transmitters Level Reference Leg:

N/A Unique System

Description:

N/A