ML17312B749

From kanterella
Revision as of 00:02, 8 January 2025 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Requests to Review Eddy Current Data Associated W/Low Row U-bends Characterized as Cracklike During Sept 1997 Refueling Outage & Previous Outage Insp Data & Latest Insp Data for Similarly Dispositioned Tubes Currently in Service
ML17312B749
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 10/30/1997
From: Thomas K
NRC (Affiliation Not Assigned)
To: James M. Levine
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
References
NUDOCS 9711120136
Download: ML17312B749 (4)


Text

Mr. James M. Levine Executive Vice President, Nuclear Arizona Public Service Company Post Office Box 53999

Phoenix, Arizona 85072-3999 October 30, 19

SUBJECT:

REVIEW OF STEAM GENERATOR INSPECTION DATA FOR THE PALO VERDE NUCLEAR GENERATING STATION, UNIT 2

Dear Mr.-Levine:

In September 1997, Arizona Public Service Company (APS) completed steam generator (SG) tube eddy current (EC) inspections in the Palo Verde Unit 2 steam generators during the end-of-cycle 7 refueling outage.

During cycle 7

operation, APS tracked a small primary to secondary leak in the f21 SG in the 1-2 gpd range with a spike up to about 4 gpd just prior to shutdown.

APS erformed a secondary side pressurization test and identified a positive eakage source at tube R1C56.

The indication 'had been identified during the previous outage with a plus point probe, dispositioned as due to geometry

("GEO") and thus was not repaired.

In an effort to better understand the inspection results.

the NRC would like to review the eddy current data associated with the low row U-bends characterized as cracklike during the September 1997 refueling outage.

For the September 1997 inspections of the low row U-bend tube indications characterized as cracklike, provide an optical disk containing the plus point and pancake coil eddy current data and associated calibration setups in the Eddynet format.

In addition, please provide for these same tubes, the previous outage inspection data and the latest inspection data for similarly dispositioned tubes currently in service in Units 1 and 3 (i.e., tubes in service with "GEO" calls).

We appreciate your assistance'in this matter'.

If you have any questions, please contact me at (301) 415-1362.

Docket No.

STN 50-529 cc:

See next page 97iii20i36 97i030 PDR ADQCK 05000528 8

PDR Sincerely, Original, Signed By

'Kristine M. Thomas, Project Manager Project Directorate. IV-2 Division of Reactor Projects

- III/IV Office of Nuclear Reactor Regulation DISTRIBUTION:

4'Docket F~ile

ACRS, TWFN PUBLIC TSullivan, EMCB PDIV-2 Reading
OGC, 015B18 EAdensam

'Perkins.

WCFO

.WBateman

TGwynn, RIV KThomas DKirsch.

WCFO EPeyton

SCoffin, EMCB OFC PDIV-2/PM DOCUMENT NAME: PVSG.LTR PDIV-2/LA EMCB:BC

ÃIMRlE II',a<~ m<I ZZI V NAME K

ortIas:ye EPWS TSulliva DATE 104 /97 1048/97 10ih/97 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII

I I

Mr. James M. Levine October 30, 1997 CC:

Mr. Steve Olea Arizona Corporation Commission 1200 W. Washington Street

Phoenix, Arizona 85007 Douglas Keht Porter Senior Counsel Southern California Edison Company Law Department, Generation Resources P.O.

Box 800

Rosemead, California 91770 Senior Resident Inspector USNRC P. 0.

Box 40 Buckeye, Arizona 85326 Regional Administrator, Region IV U. S. Nuclear Regulatory Commission

~Harris Tower It Pavillion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064

Chairman, Board of Supervisors ATTN:

Chairman 301 W. Jefferson, 10th Floor

Phoenix, Arizona 85003 Mr. Aubrey V. Godwin, Director Arizona Radiation Regulatory Agency 4814 South 40 Street
Phoenix, Arizona 85040 Ms. Angela K. Krainik, Manager Nuclear Licensing Arizona Public Service Company P.O.

Box.52034

Phoenix, Arizona 85072-2034 Mr. John C. Horne, Vice President Power Supply Palo Verde Services 2025 N. Third Street, Suite 220 Phoenix, Arizona 85004 Mr. Robert Burt Los Angeles Department of Water 5 Power Southern California Public Power Authority ill North Hope Street, Room 1255-B Los Angeles, California 90051 Mr. David Summers Public Service Company of New Mexico 414 Silver SW, ¹0604 Albuquerque, New Mexico 87102 Mr. Robert D. Bledsoe Southern California Edison Company 14300 Mesa
Road, Drop D41-SONGS San Clemente, California 92672 Mr. Robert Henry Salt River Project 6504 East Thomas Road Scottsdale, Arizona 85251 Terry Bassham, Esq.

General Counsel El Paso Electric Company 123 W. Mills El Paso, Texas 79901

v h

l

$ 1 t