ND-19-0152, Enclosure 2, Presentation Material: Functional Arrangement (FA) ITAAC, FA System Package Examples -Closed Meeting (Non-Proprietary)

From kanterella
Revision as of 04:59, 5 January 2025 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Enclosure 2, Presentation Material: Functional Arrangement (FA) ITAAC, FA System Package Examples -Closed Meeting (Non-Proprietary)
ML19044A745
Person / Time
Site: Vogtle  
Issue date: 02/14/2019
From:
Georgia Power Co, Southern Nuclear Operating Co
To:
Office of New Reactors
Shared Package
ML19044A737 List:
References
ND-19-0152
Download: ML19044A745 (26)


Text

Southern Nuclear Operating Company ND-19-0152 Vogtle Electric Generating Plant (VEGP) Units 3 and 4 Presentation Material:

Functional Arrangement (FA) ITAAC, FA System Package Examples - Closed Meeting (Non - Proprietary)

(Enclosure 2 consist of 26 pages, including this cover page)

Functional Arrangement (FA)

ITAAC FA System Package Examples Closed Meeting (Non - Proprietary)

February 14, 2019 ND-19-0152 Page 2 of 26 ONE TEAM. ONE VISION. ONE GOAL.

2 Agenda

  • Examples of FA ITAAC and Documentation

.. ~ Southern Nuclear A Georgia Power Building the future of nuclear power in America

3 FA Example #1 -WSS

  • The Design Description in COL Appendix C section 2.3.12 provides a description of what the system does:

The solid radwaste system (WSS) receives, collects, and stores the solid radioactive wastes received prior to their processing and packaging by mobile equipment for shipment off-site.

ND-19-0152 Page 4 of 26

4 Example #1 -WSS

  • The major system components to accomplish this are included in Table 2.3.12-2 (there is no Tier 1 Figure for WSS):

ND-19-0152 Page 5 of 26

5 Example #1 -WSS List of Items

  • Using guidance from ND-RA-001-012, these Two (2) Items represent the scope of the WSS Walkdown a,c ND-19-0152 Page 6 of 26

6 Example #1 -WSS Field Sketch a,c ND-19-0152 Page 7 of 26

7 FA Example #2 -PXS

  • The Design Description in COL Appendix C section 2.2.3 provides a description of what service the system is intended to provide:

The passive core cooling system (PXS) provides emergency core cooling during design basis events. The PXS is as shown in Figure 2.2.3-1 and the component locations of the PXS are as shown in Table 2.2.3-5.

Table 2.2.3-4 Inspections, Tests, Analyses, and Acceptance Criteria No.

ITAAC No.

Design Commitment Inspections, Tests, Analyses Acceptance Criteria 158 2.2.03.01

1. The functional arrangement of the PXS is as described in the Design Description of this Section 2.2.3.

Inspection of the as-built system will be performed.

The as-built PXS conforms with the functional arrangement as described in the Design Description of this Section 2.2.3.

ND-19-0152 Page 8 of 26

8 Example #2 -PXS

  • The major system components to accomplish this shown in Figure 2.2.3-1 (Sheet 1):

ND-19-0152 Page 9 of 26

9 Example #2 -PXS

  • The major system components to accomplish this shown in Figure 2.2.3-1 (Sheet 2):

ND-19-0152 Page 10 of 26

10 Example #2 -PXS

  • The major system components to accomplish this are included in Table 2.2.3-5:

ND-19-0152 Page 11 of 26

11 Example #2 -PXS List of Items Using guidance from ND-RA-001-012, this LOI is the scope of the PXS Walkdown (Four (4) of 103 Line Items Shown a,c ND-19-0152 Page 12 of 26

12 Example #2 -PXS Field Sketch (One of Five (5))

a,c ND-19-0152 Page 13 of 26

13 FA Example #3 -DWS

  • The Design Description in COL Appendix C section 2.3.14 provides a description of what the system does:

The demineralized water transfer and storage system (DWS) receives water from the demineralized water treatment system (DTS), and provides a reservoir of demineralized water to supply the condensate storage tank and for distribution throughout the plant.

ND-19-0152 Page 14 of 26

14 Example #3 -DWS

  • ITAAC 2.3.14.01 (Continued):
  • The Design Description in COL Appendix C section 2.3.14 goes on to provide additional description of what the DWS does:

Demineralized water is processed in the DWS to remove dissolved oxygen. In addition to supplying water for makeup of systems which require pure water, the demineralized water is used to sluice spent radioactive resins from the ion exchange vessels in the chemical and volume control system (CVS), the spent fuel pool cooling system (SFS), and the liquid radwaste system (WLS) to the solid radwaste system (WSS)

ND-19-0152 Page 15 of 26

15 Example #3 -DWS

  • The major system components to accomplish this are included in Table 2.3.14-3 (there is no Tier 1 figure for DWS):
  • Because there is no Tier 1 figure for DWS and limited components listed on Table 2.3.14-3, four additional components were added per procedure ND-RA-001-012 to address the design description.

ND-19-0152 Page 16 of 26

16 Example #3 - DWS List of Items

  • Using guidance from ND-RA-001-012, this LOI is the scope of the DWS Walkdown (3 of 20 Line Items shown) a,c ND-19-0152 Page 17 of 26

17 Example #3 -DWS Field Sketch (One of Five (5))

a,c ND-19-0152 Page 18 of 26

18 System Safety Functions in Other ITAAC ND-19-0152 Page 19 of 26

19 System Safety Functions in Other ITAAC ND-19-0152 Page 20 of 26

20 System Safety Functions in Other ITAAC ND-19-0152 Page 21 of 26

21 System Safety Functions in Other ITAAC ND-19-0152 Page 22 of 26

22 System Safety Functions in Other ITAAC ND-19-0152 Page 23 of 26

23 System Safety Functions in Other ITAAC ND-19-0152 Page 24 of 26

24 System Safety Functions in Other ITAAC ND-19-0152 Page 25 of 26

25 Questions ND-19-0152 Page 26 of 26

.. ~ Southern Nuclear A Georgia Power Building the future of nuclear power in America