TXX-3491, Interim Deficiency Rept Re Orifice Plates Supplied Outside of Tolerance,Initially Reported 811120.Evaluation in Progress.Completion Projected by 820611

From kanterella
Revision as of 19:26, 19 December 2024 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Interim Deficiency Rept Re Orifice Plates Supplied Outside of Tolerance,Initially Reported 811120.Evaluation in Progress.Completion Projected by 820611
ML20042B801
Person / Time
Site: Comanche Peak  
Issue date: 03/10/1982
From: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
TXX-3491, NUDOCS 8203260164
Download: ML20042B801 (1)


Text

t/g 9

[

ei w/"',., -g;O 3,

TENAS UTluTIES GENERATING Cmil%NY 28MH HHYAN TOWEH DALI.AM. TEX AN 75201 g

a?.~SiGSyssY :

o. wd 4
  • ?#$m,pa s

n.;.oA.,

"::::='=:::'

6 4

March 10,1982

/"

e TXX-3491 I

kk

/

Mr. G. L. Madsen, Chief f

1 4

Reactor Projects Branch

/

% I SIS 82 f U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement I

611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76012 COMANCHE PEAK STEAM ELECTRIC STATION ORIFICE PLATES SUPPLIED OUTSIDE OF TOLERANCE FILE N0.

10110

Dear Mr. Madsen:

On November 20, 1981, we verbally informed your Mr. R. G. Taylor of a deficiency regarding orifice plates which were manufactured outside specified tolerances. On December 17, 1981, we submitted an interim letter logged TXX-3449.

We are continuing our evaluation and anticipate completion by June 11, 1982.

Very truly.'ours, bf-R. J. Gary RJG:pko cc: NRC Region IV - (0 + 1 copy)

Director, Inspection and Enforcement - (15 copies) c/o Distribution Services Branch, DDC, ADM.

U.S. Nuclear Regulatory Conunission Washington, DC 20555 8203260164 B20310

[

7 PDR ADOCK 05000445 hj S

PDR

.