Letter Sequence Request |
|---|
EPID:L-2022-LLR-0012, L-PI-22-004 Prairie Island Nuclear Generating Plant, Unit 2, 10 CFR 50.55a Request No. RR-08, Request for Alternative to ISTC 3630(f) (Approved, Closed) |
|
MONTHYEARL-PI-22-004, L-PI-22-004 Prairie Island Nuclear Generating Plant, Unit 2, 10 CFR 50.55a Request No. RR-08, Request for Alternative to ISTC 3630(f)2022-02-0808 February 2022 L-PI-22-004 Prairie Island Nuclear Generating Plant, Unit 2, 10 CFR 50.55a Request No. RR-08, Request for Alternative to ISTC 3630(f) Project stage: Request ML22039A3402022-02-0808 February 2022 L-PI-22-004 Prairie Island Nuclear Generating Plant, Unit 2, 10 CFR 50.55a Request No. RR-08, Request for Alternative to ISTC 3630(f) Project stage: Request ML22045A4972022-02-14014 February 2022 NRR E-mail Capture - Prairie Island Nuclear Generating Plant, Unit 2 - Acceptance of Alternative Request Alternative Related PIV Leakage Monitoring Project stage: Acceptance Review L-PI-22-034, Response to RAI, Alternative RR-08 Related to Pressure Isolation Valve Monitoring and Testing2022-07-14014 July 2022 Response to RAI, Alternative RR-08 Related to Pressure Isolation Valve Monitoring and Testing Project stage: Response to RAI ML22270A3252022-09-30030 September 2022 (Prairie Island), Unit 2 - Authorization and Safety Evaluation for Alternative Request No. RR-08 Project stage: Approval 2022-02-08
[Table View] |
Text
LPI22004 Page1of1
SimplifiedfromUpdatedSafetyAnalysisReportFigure6.22A.
Showingvalve2SI64and2SI63configurationwithrespectto ReactorCoolantSystemand21SafetyInjectionAccumulator.