Nuscale, Table 9.1.4-2 - Classification of Structures, Systems, and Components
ML23306A276
Person / Time
Site: 05200050
Issue date: 11/02/2023
From:
NuScale
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23306A273 List:
References
LO-152903
Download: ML23306A276 (1)


Text

Table 9.1.4-2: Classification of Structures, Systems, and Components NuScale US460 SDAA NuScale Final Safety Analysis Report SSC (Note 1) Location SSC Augmented Design Quality Group/Safety Seismic Classification Requirements Classification (Ref Classification (Ref.

(A1, A2, B1, B2) (Note 2) RG 1.26 or RG 1.143) RG 1.29 or RG 1.143)

(Note 3) (Note 4)

FHE, Fuel Handling Equipment

  • Fuel handling machine RXB B2
  • ANSI-ANS-57.1-1992 N/A I
  • New fuel elevator

New fuel jib crane RXB B2

  • ANSI/ANS 57.2-1983 (with additions, clarifications and exceptions of RG 1.13) 9.1-42 Note 1: Acronyms used in this table are listed in Table 1.1-1 Note 2: Additional augmented design requirements, such as the application of a Quality Group, Radwaste safety, or seismic classification, to nonsafety-related SSC are reflected in the columns Quality Group / Safety Classification and Seismic Classification, where applicable. Environmental Qualifications of SSC are identified in Table 3.11-1.

Note 3: Section 3.2.2.1 through Section 3.2.2.4 provides the applicable codes and standards for each RG 1.26 Quality Group designation (A, B, C, and D). A Quality Group classification per RG 1.26 is not applicable to supports or instrumentation that do not serve a pressure boundary function. Section 3.2.1.4 provides a description of RG 1.143 classification for RW-IIa, RW-IIb, and RW-IIc.

Note 4: Where SSC (or portions thereof) as determined in the as-built plant that are identified as Seismic Category III in this table could, as the result of a seismic event, adversely affect Seismic Category I SSC or result in incapacitating injury to occupants of the control room, they are categorized as Seismic Category II consistent with Section 3.2.1.2 and analyzed as described in Section 3.7.3.8.