TXX-4404, Requests NRC Approval of Use of ASME Code Case N-397 & N-411 for Analysis of ASME Class 1,2 & 3 Piping.Application of Code Cases Provides Sufficient Levels of Conservatism to Assure Functionability Under Design Conditions

From kanterella
Revision as of 23:35, 24 July 2023 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Requests NRC Approval of Use of ASME Code Case N-397 & N-411 for Analysis of ASME Class 1,2 & 3 Piping.Application of Code Cases Provides Sufficient Levels of Conservatism to Assure Functionability Under Design Conditions
ML20102B855
Person / Time
Site: Comanche Peak  
Issue date: 01/25/1985
From: Beck J
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Harold Denton
Office of Nuclear Reactor Regulation
References
TXX-4404, NUDOCS 8503040453
Download: ML20102B855 (1)


Text

m

  • ^ ~

/ y ,

(/l t Log # XX-4404 File # 905.4 TEXAS UTILITIES GENERATING COMPANY

{r[hQ ,,x,wAv rowen . .oo sonru ouve Mrnm, i..u. m . DAM.AM, TeXAM WOI To Aol L I

. 'f,H, ,

CK January 25, 1985 Td Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION DOCKET NOS. 50-445 AND 50-446 CODE CASE USAGE

Dear Mr. Denton:

In accordance with 10CFR50.55a(a)(3) NRC approval is requested for the usage of ASME Code Cases N-397 and N-411 for the analysis of ASME Class 1, 2 and 3 piping at CPSES Units 1 and 2.

Code Case N-397 contains an alternative method to spectral broadening which is a more reasonable and realistic approach to piping analysis.

Code Case N-411 contains alternative damping factors that can be used in lieu of values contained in Section III, Division I, Table N-1230-1 of the ASE Code. These damping values are more reasonable and realistic values to use in the seismic analysis of piping.

Applying these code cases to CPSES Units 1 and 2 piping analyses still provides sufficient levels of conservatism to assure functionability under the design conditions.

Should you have additional questions in this matter, please contact this office.

Respec tfully, W w.%-

ohn W. Beck BSD/grr c- J. J. Stefano 8503040453 850125

[DR ADOCK 05000445 PDR

\

?9

. . . . . . . . , - . , . . . . - . . . , . . . y

. - - - - - - . .. --