Insp Findings & Licensee Ack on 850619-20 of License 50-23204-01.Insp Findings:Physical Inventories of Sealed Sources Not Performed at Proper Intervals & Records Did Not Indicate Location of Sealed Sources or Date of Inventory
ML20132C168
Person / Time
Site: 03020360
Issue date: 06/28/1985
From: Skov D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
References
NUDOCS 8507290652
Download: ML20132C168 (1)


See also: IR 05000232/2004001

Text

_- - - _ - - - - . _ _ - _ _ _ _ _- - _-___ - -_ - -

__

!

I "RC Form 501 4 U.S. NUCLEAR REaULATORY COMMIS8 tan

l (12C1) -

10 CFR 2.201

SAFETY INSPECTION

1. LICENSE E 2. REGIONAL OFFICE

F Shannon & Wilson, Inc. U. S. Nuclear Regulatory Commission

dba An: tic Alaska Testing Laboratories Region V

2055 Hill Road 1450 Maria Lane, Suite 210

Pe 0.. Box 843 Walnut Creek, CA 94596

Fairbanks, Alaska 99707

3 90CKET NUMBER (S) 4. LICENSE NUMBER (S) 5. D ATE OF INSPECTION

030-20360 50-23204-01 , June 19-20e 1985

Licensee:

o

Thiinspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear

Regulatory Commissior/s (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures

tnd representative records, interviews, with personnel, and observations by the inspector. The findings as a result of this inspection are as follows:

] 1. Within the scope of this inspection, no violatiors were observed.

] 2. The inspector also verified the steps you have taken to correct the violations identified during'the last inspection. We have no further questions on

those actions at this time.

] 3. During this inspection certain of your activities,as checked below, were in violation of NRC requirements.

THIS IS A NOTICE OF VIOLATION which is required to be posted in accordance with 10 CFR 19.11.

A. was not properly posted to indicate the presence

ofa .10 CFR 20.203(b), (c), (d), (e) or 34.42.

B. Containers located in were not properly

labeled to indicate the presence of radioactive material.10 CFR 20 203(f)(1), or (f)(2).

C. Phvtical inventariet of sealed sources were not perforrrad at the proper

frequencies.10 CFR License Condition Number 15. In addition.

all physical inventory records did not indicate location of sealed sources nor date of

D. Records of $4Wettsem3frJy maintained

10 CFR or License Condition Number

E. Documents were not properly posted or otherwise made available.10 CFR 19.11.

.

] F. Reports or notifications of were not made in accordance

with 10 CFR or Licornse Condition Number

X H. Ti.m maletura rinne 4ty nmenae, ameh cantain{nn 5n millieurfac nf smaricine 741_ anal

10 m1111 curies of ses cesium-137e were not properly secured to prevent unauthorized

removal from the place of storage plalk-In freezer room #1). 10 R K ZU.ZU/(a)

i.

X J. gamlast engrene enntaininn $n m{ll_ {re_arip3 nf amarleitam 7dl_ mt{ 1ff millicurist of

cesium-137e which are contained in the Troxler gauge, Serial tio. 9003, were not leak

testea within tne previous six m65ths prior to use in 1983, 1984 and 1985, i.icense

Og Condition 13. 850729065

REG 5 LIC3 628

50-23204'01 PDR

l hira?by state that within 30 day a the actions described by me to the inspector wm ow se.... .. es violations identified in the items checked above.

This statement of corrective actions is made in accordance with the requirements of 10 CF R 2.201. No further response will be submitted unless required by

he N R C.

M M]n '

SIGW ATU RI . 'L ICE MI.E'

,nkr

8DMTE

Qvm w SIGNATURE - NRC 6NSPECTOR

4helsr

I DATE

.