ML20212P690
ML20212P690 | |
Person / Time | |
---|---|
Issue date: | 08/28/1986 |
From: | Heishman R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) |
To: | Condit T UNISTRUT CORP. |
Shared Package | |
ML20212P693 | List: |
References | |
REF-PT21-86, REF-QA-99900362 NUDOCS 8609030240 | |
Download: ML20212P690 (2) | |
Text
l 1 .
p rar l
6 6 % UNITED STATES f
i NUCLEAR REGULATORY COMMISSION l i
j WASHINGTON, D. C. 20555 L
\...../ August 28, 1986 i
Docket No. 99900362/86-01 Unistrut Corporation ATTN: Mr. Timothy B. Condit Senior Vice President 35005 Michigan Avenue West Wayne, Michigan 48184 Gentlemen:
This refers to the inspection conducted by J. C. Harper of this office on June 2-6, 1986, of your facility at Wayne, Michigan and to the discussions of our findings with Bruce McClure and members of your staff at the conclusion of the inspection.
The purpose of, this inspection was to evaluate the implementation of Unistrut's QA program and to follow-up on deficiency reports regarding defective spot welds on Systems Control Corporation cable tray hangers installed at the Byron and Braidwood Nuclear Power Stations. Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspec-tion consisted of an examination of procedures and representative records, in-terviews with personnel, and observations by the inspector.
During the inspection it was found that the implementation ~ of your QA program failed to meet certain NRC requirements. Violations and nonconformances were identified in the areas of implementing 10 CFR Part 21, performing internal and external audits, handling nonconforming material, and qualifying inspec-tors and lead auditors. The specific findings and references to the pdrtinent requirements are identified in the enclosures to this letter.
The enclosed Notice of Violation is sent to you pursuant to the provisions of Section 206 of the Energy Reorganization Act of 1974. You are required to submit to this office within 30 days from the date of this letter a written statement containing: (1) a description of steps that have been or will be taken to correct these items; (2) a description of steps that have been or will be taken to prevent recurrence; and (3) the dates your corrective actions and preventive measures were or will be completed. Consideration may be given to extending your response time for good cause shown.
You are also requested to submit a similar written statement for each item which appears in the enclosed Notice of Noncoaformance.
i 8609030240
^
860828
) 0006$99 NvUMT ,
Unistrut Corporation August 28, 1986 The response requested by this letter is not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.
In accordance with 10 CFR 2.790 of the Comission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, .,
original signed by:
9 Robert F. Heishman, Chief Vendor Program Branch Division of Quality Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement
Enclosures:
- 1. Appendix A-Notice of Violation
- 2. Appendix B-Notice of Nonconformance
- 3. Appendix C-Inspection Report No. 99900362/86-01
- 4. Appendix D-Inspection Data Sheets (2 pages)
DI BUTION:
JMB:IE:09 VPB Rdg 00AVT Rdg JStone LParker _
JHarper EMerschnff RHeishman BGrimes HMiller RStarostecki
- See previous page for concurrences. I r)
VPB:00AVT SC/VPB:00AVT BC/VAB:DQAVT l JHarper* EMerschoff* RFH hman 08/19/86/db 08/25/86 0 /86
. -