MONTHYEARML20217E3021999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for Pilgrim Nuclear Station.With ML20216E6881999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Pilgrim Nuclear Power Station.With ML20210R3401999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Pilgrim Nuclear Power Station.With ML20209E6191999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Pilgrim Nuclear Power Station.With ML20195G8231999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Pnps.With ML20206J6611999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Pilgrim Nuclear Power Station.With ML20205L0221999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Pilgrim Nuclear Power Station.With ML20207H5451999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Pilgrim Nuclear Power Station.With ML20206Q2741998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Pilgrim Nuclear Power Station.With ML20197J3591998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Pilgrim Nuclear Power Station.With ML20195C9951998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Pilgrim Nuclear Power Station.With ML20154K0721998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Pilgrim Nuclear Power Station.With ML20151W8231998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Pilgrim Nuclear Power Station.With ML20237A9941998-07-31031 July 1998 Monthly Operating Rept for Pilgrim Nuclear Power Station ML20236P0151998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Pilgrim Nuclear Power Station ML20249A3741998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Pilgrim Nuclear Power Station.W/Undated Ltr ML20247H2081998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Pilgrim Nuclear Power Station ML20216G3911998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Pilgrim Nuclear Power Station ML20248L2241998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Pilgrim Nuclear Station ML20202G5251998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Pilgrim Nuclear Power Station ML20198L7701997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Pilgrim Nuclear Power Station ML20203D6101997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for Pilgrim Nuclear Power Station BECO-LTR-97-111, Monthly Operating Rept for Oct 1997 for Pilgrim Nuclear Power Station1997-10-31031 October 1997 Monthly Operating Rept for Oct 1997 for Pilgrim Nuclear Power Station ML20217H5621997-09-30030 September 1997 Monthly Operating Rept for Sept 1997 for Pilgrim Nuclear Power Station ML20216J4131997-08-31031 August 1997 Monthly Operating Rept for Aug 1997 for Pilgrim Nuclear Power Station ML20210J3321997-07-31031 July 1997 Monthly Operating Rept for Jul 1997 for Pilgrim Nuclear Power Station ML20148K4161997-05-31031 May 1997 Monthly Operating Rept for Pilgrim Nuclear Power Station ML20141B9631997-04-30030 April 1997 Monthly Operating Rept for Apr 1997 for Pilgrim Nuclear Power Station ML20137T5631997-03-31031 March 1997 Monthly Operating Rept for Mar 1997 for Pilgrim Nuclear Power Station ML20136G7791997-02-28028 February 1997 Monthly Operating Rept for Feb 1997 for Pilgrim Nuclear Power Station ML20138K5811997-01-31031 January 1997 Monthly Operating Rept for Jan 1997 for Pilgrim Nuclear Power Station ML20133G5831996-12-31031 December 1996 Monthly Operating Rept for Dec 1996 for Pilgrim Nuclear Power Station BECO-96-106, Monthly Operating Rept for Nov 1996 for Pilgrim Nuclear Power Station1996-11-30030 November 1996 Monthly Operating Rept for Nov 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-097, Monthly Operating Rept for Oct 1996 for Pilgrim Nuclear Power Station1996-10-31031 October 1996 Monthly Operating Rept for Oct 1996 for Pilgrim Nuclear Power Station ML20128N2611996-09-30030 September 1996 Monthly Operating Rept for Sept 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-083, Monthly Operating Rept for Pilgrim Nuclear Power Station for Aug 1996 Ltr1996-08-31031 August 1996 Monthly Operating Rept for Pilgrim Nuclear Power Station for Aug 1996 Ltr ML20116L0841996-07-31031 July 1996 Monthly Operating Rept for Jul 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-066, Monthly Operating Rept for June 1996 for Pilgrim Nuclear Power Station1996-06-30030 June 1996 Monthly Operating Rept for June 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-056, Monthly Operating Rept for May 1996 for Pilgrim Nuclear Power Station1996-05-31031 May 1996 Monthly Operating Rept for May 1996 for Pilgrim Nuclear Power Station ML20117E0961996-04-30030 April 1996 Monthly Operating Rept for Apr 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-034, Monthly Operating Rept for Mar 1996 for Pilgrim Nuclear Power Station1996-03-31031 March 1996 Monthly Operating Rept for Mar 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-023, Monthly Operating Rept for Feb 1996 for Pilgrim Nuclear Power Station1996-02-29029 February 1996 Monthly Operating Rept for Feb 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-008, Monthly Operating Rept for Jan 1996 for Pilgrim Nuclear Power Station1996-01-31031 January 1996 Monthly Operating Rept for Jan 1996 for Pilgrim Nuclear Power Station BECO-LTR-96-004, Monthly Operating Rept for Dec 1995 for Pilgrim Nuclear Power Station1995-12-31031 December 1995 Monthly Operating Rept for Dec 1995 for Pilgrim Nuclear Power Station ML20095E7351995-11-30030 November 1995 Monthly Operating Rept for Nov 1995 for Pilgrim Nuclear Power Station Unit 1 BECO-LTR-95-116, Monthly Operating Rept for Oct 1995 for Pilgrim Nuclear Power Station1995-10-31031 October 1995 Monthly Operating Rept for Oct 1995 for Pilgrim Nuclear Power Station ML20093F5221995-09-30030 September 1995 Monthly Operating Rept for Sept 1995 for Pilgrim Nuclear Power Station BECO-LTR-95-097, Monthly Operating Rept for Aug 1995 for Pilgrim Nuclear Power Station1995-08-31031 August 1995 Monthly Operating Rept for Aug 1995 for Pilgrim Nuclear Power Station BECO-LTR-95-081, Monthly Operating Rept for July 1995 for Pilgrim Nuclear Power Station1995-07-31031 July 1995 Monthly Operating Rept for July 1995 for Pilgrim Nuclear Power Station BECO-LTR-95-071, Monthly Operating Rept for June 1995 for Pilgrim Nuclear Power Plant1995-06-30030 June 1995 Monthly Operating Rept for June 1995 for Pilgrim Nuclear Power Plant 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217E3021999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for Pilgrim Nuclear Station.With ML20212C2921999-09-16016 September 1999 SER Accepting Licensee Request for Relief from ASME Code Section XI Requirements as Endorsed by 10CFR50.55a for Containment Insp for Pilgrim Nuclear Power Station ML20216F3511999-09-0808 September 1999 ISI Summary Rept for Refuel Outage 12 at Pnps ML20216E6881999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Pilgrim Nuclear Power Station.With ML20210R3401999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Pilgrim Nuclear Power Station.With ML20209C4731999-07-0707 July 1999 Addendum to SE on Proposed Transfer of Operating License & Matls License from Boston Edison Co to Entergy Nuclear Generation Co ML20209H8251999-07-0101 July 1999 Provides Commission with Evaluation of & Recommendations for Improvement in Processes Used in Staff Review & Approval of Applications for Transfer of Operating Licenses of TMI-1 & Pilgrim Station ML20209E6191999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Pilgrim Nuclear Power Station.With ML20196H2451999-06-29029 June 1999 SER Denying Licensee Proposed Alternative in Relief Request PRR-13,rev 2.Staff Determined That Proposed Alternative Provides Insufficient Info to Determine Adequacy of Scope of Implementation ML20209A8901999-06-28028 June 1999 SER Accepting Licensee Proposed Alternative to Use Code Case N-573 for Remainder of 10-year Interval Pursuant to 10CFR50.55a(a)(3)(i) ML20209B9861999-06-23023 June 1999 Rev 13A to Pilgrim Nuclear Power Station COLR for Cycle 13 ML20217N9061999-06-21021 June 1999 Rept of Changes,Tests & Experiments for Period of 970422-990621 ML20195K3431999-06-15015 June 1999 Safety Evaluation Granting Licensee Request to Use Guidance of GL 90-05 to Repair Flaws in ASME Class 3 Salt Svc Water System Piping for Plant ML20195G8231999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Pnps.With ML20207E7471999-05-27027 May 1999 Safety Evaluation Granting Request Re Reduction of IGSCC Insp of Category D Welds Due to Implementation of HWC to License DPR-35 ML20206M1971999-05-11011 May 1999 SER Accepting Request for Approval to Repair Flaws in ASME Code Class 3 Salt Svc Water Piping at Plant ML20206J6611999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Pilgrim Nuclear Power Station.With ML20205L0221999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Pilgrim Nuclear Power Station.With ML20207J5471999-03-0909 March 1999 Training Simulator,1999 4-Yr Certification Rept ML20207F9401999-03-0101 March 1999 Long Term Program Semi-Annual Rept for Pilgrim Nuclear Power Station ML20207H5451999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Pilgrim Nuclear Power Station.With ML20196E2151998-12-31031 December 1998 1998 Annual Rept for Boston Edison & Securities & Exchange Commission Form 10-K Rept.With ML20206Q2741998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Pilgrim Nuclear Power Station.With ML20197J3591998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Pilgrim Nuclear Power Station.With ML20195C9951998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Pilgrim Nuclear Power Station.With ML20154K0721998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Pilgrim Nuclear Power Station.With ML20153D3901998-09-22022 September 1998 Safety Evaluation Granting 970707 Request to Use Guidance in GL 90-05 to Repair Flaws in ASME Class 3 Salt Svc Water Sys Piping for Pilgrim Nuclear Power Station ML20197C5011998-09-0404 September 1998 Rev 12C,Pages 4 & 5 to Pilgrim Nuclear Power Station Colr ML20197C5471998-08-31031 August 1998 Rev 12C to Pilgrim Nuclear Power Station Colr ML20151W8231998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Pilgrim Nuclear Power Station.With ML20237E2251998-08-26026 August 1998 Suppl & Revs to SE for Amend 173 for Pigrim Nuclear Power Station ML20237A9941998-07-31031 July 1998 Monthly Operating Rept for Pilgrim Nuclear Power Station ML20236U8201998-07-13013 July 1998 Rev 12B to Pilgrim Nuclear Power Station COLR (Cycle 12) ML20236P0151998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Pilgrim Nuclear Power Station ML20249A3741998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Pilgrim Nuclear Power Station.W/Undated Ltr ML20247H2081998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Pilgrim Nuclear Power Station ML20207B7601998-03-31031 March 1998 Final Rept, Pilgrim Nuclear Power Station Site-Specific Offsite Radiological Emergency Preparedenss Prompt Alert & Notification System Quality Assurance Verification, Prepared for FEMA ML20216G3911998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Pilgrim Nuclear Power Station ML20216J3741998-03-19019 March 1998 Safety Evaluation Accepting Licensee Request to Evaluate Elevated Tailpipe Temp on Safety Relief Valve SRV 203-3B ML20248L2241998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Pilgrim Nuclear Station ML20202G5251998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Pilgrim Nuclear Power Station ML20236M8511997-12-31031 December 1997 1997 Annual Rept for Boston Edison & Securities & Exchange Commission Form 10-K Rept ML20198L7701997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Pilgrim Nuclear Power Station ML20203D6101997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for Pilgrim Nuclear Power Station ML20202D5761997-11-0808 November 1997 1997 Evaluated Exercise BECO-LTR-97-111, Monthly Operating Rept for Oct 1997 for Pilgrim Nuclear Power Station1997-10-31031 October 1997 Monthly Operating Rept for Oct 1997 for Pilgrim Nuclear Power Station ML20217D6431997-10-0101 October 1997 Safety Evaluation Granting Request for Approval to Repair Flaws in Accordance W/Gl 90-05 for ASME Class 3 SSW Piping for Pilgrim ML20217H5621997-09-30030 September 1997 Monthly Operating Rept for Sept 1997 for Pilgrim Nuclear Power Station ML20216J4131997-08-31031 August 1997 Monthly Operating Rept for Aug 1997 for Pilgrim Nuclear Power Station ML20210J3321997-07-31031 July 1997 Monthly Operating Rept for Jul 1997 for Pilgrim Nuclear Power Station 1999-09-08
[Table view] |
Text
'i ,
- r. :
U Tech. Spec. 6.9.A.2 BOSTON EDISON P,lgum Nudear Power Station Rocky Hi;l Road Plymoum, Massachusetts 02360 E. T. Boulette, PhD Senior Vee Pres &nt - Nuclear May 13 , 1994 BEco Ltr. #94- 056 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Docket No. 50-293 License No. DPR-35 APRIL 1994 MONTHLY REPORT in accordance with PNPS Technical Specification 6.9. A.2, a copy of the Operational Status Summary for Pilgrim Nuclear Power Station is attached for your information and planning. Should you have any questions concerning this report please contact me directly.
^-
E. T. Boulette, Ph WJM/ lam /9458 Attachment cc: Mr. Thomas T. Martin Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident inspector
%* 1 s gusa 9405170192 DR 940430 pj ADOCK 05000293 -v l !
PDR 1 l
I
, l OPERATING DATA REPORT I
- DOCKET NO. 50-293 DATE May 13, 1994 COMPLETED BY: W. Munro TELEPHONE (508) 830-8474
' OPEPATING STATUS NOTES ,
.1. Unit Name Pilgrim I
- 2. Reporting Period April 1994
- 3. Licensed Thennal Power (MWt) 1998
- 4. Nameplate Rating (Gross MWe) 678
' 5. . Design Electrical Rating (Net MWe) Sjil
- 6. Maximum Dependable Capacity (Gross MWe) ERE
- 7. Maximum Dependable Capacity (Net MWe) 5.7_Q
- 8. If Changes Occur in Capacity Ratings (Item Number 3 Through 7) Since Last Report, Give Reasons:
Jane
- 9. Power Level To Which Restricted, If Any (Net MWe): None
- 10. Reasons For Restrictions, If Any: N/A P
This Month Yr-to-Data Qtmulative
- 11. Hours in Reporting Period 719.0 2879.0 187511.0
- 12. Hours Reactor Critical 579.8 2586.0 115527.5
- 13. Hours Reactor Reserve Shutdown 0.0 0.0 0.0
- 14. Hours Generator On-Line 560.3 2477.2' 111266.2
- 15. Hour., Unit Reserve Shutdown 0.0 0.0 0.0
- 16. Gross Thermal Energy Generated MWH) 936528.0 4605288.0 195750024.0 ,
- 17. Gross Electrical Energy Generated (MWH) 317640.0 1579810.0 66225744.0
- 18. Net Electrical Energy Generated (MWH) 305081.0 1520182.0 63653876.0
- 19. Unit Service Factor 77 d 86 0 59.3
- 20. Unit Availability Factor 77.9 86.0 59.3
- 21. Unit Capacity Factor (Using MDC Net) 63.3 78.8 50.7
- 22. Unit Capacity Factor (Using DER Net) 64.8 80.6 51.8 23 Unit Forced Outage Rate 22.1 6.8 11.7 -i i 24. Shutdowns scheduled over next 6 months (type, date, and duration of each) - MCO l October - 30 Days ,
- 25. If shutdown at end of report period, estimated date of startup - 5/1/94
~l, l
1
Y l AVER 1fLE DAILY UNIT POWER LEVEL DOCKET NO. 50-293 DATE: May 13, 1994 COMPLETED BY: W. Mungo TELEPHONE: (508) 830-8474 MONTil April 1994 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 664 17 375 2 664 18 353 3 637 19 354 4 663 20 341 5 663 21 272 6 664 22 261 ,
7 664 23 0 8 662 24 0 9 663 25 0 10 664 26 0 11 663 27 0 12 662 28 0 13 663 29 49 ,
14 662 30 126 15 661 16 662 This format lists the average daily unit power level in MWe-Net for each day in the reporting month, computed to the nearest whole megawatt.
1
1 .
4 .
BOSTON EDISON COMPANY PILGRIM NUCLEAR POWER STATION DOCKET NO. 50-293 OPERATIONAL SU_MMARY FOR APRIL 1994 The unit started the reporting period at 100 percent core thermal power (CTP) where it was essentially maintained until April 17, 1994 On April 17, 1994, reactor power was reduced to approximately 50 percent CTP to facilitate a thermal backwash of the main condenser, and perform control rod scram time testing. During the testing, at approximately 56 percent CTP, a number of the control rods exhibited an increased 10 percent scram insertion time. Also one control rod (10-31) failed to fully insert within 7 seconds in accordance with the acceptance criteria. This control rod was declared inoperable, fully inserted, and electrically disabled. Disassembly of the control rod's scram solenoid pilot valve, revealed one completely failed exhaust diaphragm and an embrittled and cracked pressure diaphragm. Other control rods which had exhibited slow or degraded scrar insertion times were disassembled and upon inspection revealed diaphragms in various degrees of degradation. On April 20, 1994, while the rod scram time testing continued, reactor power was reduced to approximately 43 percent CTP to facilitate troubleshooting of the Augmented Offgas (AOG) System. On April 22, 1994, following the discovery of additional diaphragms with significant degradation, the decision was made to shut the plant down so that the scram solenoid pilot diaphragms on all 145 hydraulic control units (HCU) could be replaced. At 2321 hours0.0269 days <br />0.645 hours <br />0.00384 weeks <br />8.831405e-4 months <br /> on April 22, 1994, the main turbine was manually tripped off-line, and at 0331 hours0.00383 days <br />0.0919 hours <br />5.472884e-4 weeks <br />1.259455e-4 months <br /> on April 23, 1994, a controlled shutdown of the reactor was completed. Following HCU maintenance, the reactor was made critical at 2245 hours0.026 days <br />0.624 hours <br />0.00371 weeks <br />8.542225e-4 months <br /> on April 28, 1994, and the main generator was synchronized to the grid at 1046 hours0.0121 days <br />0.291 hours <br />0.00173 weeks <br />3.98003e-4 months <br /> on April 29, 1994. Power was increased to approximately 25 percent CTP where it was essentially maintained to perform post work testing of the control rods. On April 30, ,
1994, at 2051 hours0.0237 days <br />0.57 hours <br />0.00339 weeks <br />7.804055e-4 months <br /> the main generator was manually tripped offline to facilitate a weld repair on the extraction steam line entering the train "B" second point feedwater heater.
The unit remained offline for the remainder of the reporting period.
SAFETY RELIEF VALVE CHALLENGES MOiUH OF APRIL 1994 Requirement: NUREG-0737 T.A.P. II.K.3.3 There were no safety relief valve challenges during the reporting period. >
An SRV challenge is defined as anytime an SRV has received a signal to operate via reactor pressure, auto signal (ADS) or control switch (manual) Ref. BECo ltr. #81-01 date 01/05/81.
f i
l i
y, _ w, m _
.-. . . . . _ _ _ - , - - m- . < . . - - . -
I 4
REFUEkING INFORMATJ2N The~following refueling information is included in the Monthly Report as requested in an NRC letter to BECo, dated January 18, 1978:
For your convenience, the information supplied has been enumerated so that each number corresponds to equivalent notation utilized in the request.
- 1. The name of this f acility is Pilgrim Nuclear Power Statior . Docket Number 50-293,
- 2. . Scheduled date for next refueling shutdown: April 1, 1995
- 3. Scheduled date for restart following next refueling: May 26, 1995
- 4. Due to their similarity, requests 4, 5, & 6 are responded to collectively under #6.
- 5. See #6.
- 6. The new fuel loaded during the 1993 refueling outage was of the same design as loaded in the previous refueling outage and consisted of 140 assemblies.
7, (a) There are 580 fuel assemblies in the core.
(b) There are 1629 fuel ansemblies in the spent fuel pool.
- 8. (a) The station is presently licensed to store 2320 spent fuel assemblies. The actual usable spent fuel storage capacity is 2320 fuel assemblies.
(b) The planned spent fuel storage capacity is 2320 fuel assemblies.
- 9. With present spent fuel in storage, the spent fuel pool now has the capacity to accommodate an additional 691 fuel assemblies.
t t
l
- . - - , ,,--a , - , -
i 4
MONTH APRIL 1994 .
~
PILGRIM NUCLEAR POWER STATION PA70R SAFETY RELATED MAINTENANCE 5
i CORRECTIVE ACTION TO ASSOCIATED SYSTEM COMPCNENT MALFUNCTION CAUSE MAINTENANCE PREVENT FICURRENCE LER Centrol Rod CRD Hydraulic Scram Solenoid Root cause Replacement of To be determined N/A
- Drive (CRD) Control Units Pilot Valve under Scram Solenoid System Malfunctions. investigation Pilot Valve Failed Diaphragms on all -
Surveillance 145 CRD Hydraulic Procedure 9.9 Control Units.
Acceptance Post Maintenance Criteria during Test satisfactory, CRD scram time CRD System placed testing. in service.
Main Steam Main Steam Incorrect Gear Root cause Replaced Motor To be determined N/A (MS) System Outboard Ratio Verified under Pinion Gear and Drain Line Per Engineering investigation Worm Shaft Valve Motor Evaluation. Clutch Gear.
Operator Performed t
MO-220-2. diagnostic Votes !
, test. Post work l testing completed !
satisfactorily, and valve declared operable.
t i
h l
L J
s 4 4 MONTH APRIL 1994 .;
PILGRIM NUCLEAR POWER STATION ESTOR SAFETY RELATED MAINTENANCE ,
I
?
CORRECTIVE ACTION TO ASSOCIATED SYSTEM COMPONENT MALFUNCTION CAUSE MAINTENANCE PREVENT RECURRENCE LER 4
Reactor RBCCW Valve Valve stem Normal aging Disassembled To be determined N/A Building 30-HO-252 separated valve.
Closed from disc. Inspection
' Cooling indicated stem Water was broken in (RBCCW) half.
System Replaced stem in kind.
Replaced packing.
, Post work testing satisfactory.
Feedwater Second Steam Original Weld overlay None N/A (FW) System
- Point FW ' leak construction repair Heater "B" weld defect Train i
- Not Safety Related But Required Turbine Shutdown i
L
.~.
1
+
- '. - . - - _ - - - - - - - - - s- - + w - - _ - - - - - - _ - - - - - _ - - _ _ - - - - - -
UNIT SFUTDOWNS AND POWER REDUCTIONS DOCKET NO: 50-293 .'
DOCKET NO: 50-293 NAME: Pilorim I '
, DATE: May 13, 1994 COMPLETED BY: W. Munro TELEPHONE : (508 ) 830-8474 REPORT MONTH APRIL 1994 METHOD OF LICENSE CAUSE & CORRECTIVE DURATION SHTIITING EVENT SYSTEM COMPONENT ACTION TO PREVENT NO. DATE TYPE (HOURS) P'ASON DOWN REACTOR REPORT # CODE CODE RECURRENCE 1 2 3 4 5 4 4-17-94 S 0.0 B -
N/A N/A N/A Power Reduction -
Thermal Backwash Main Condenser 5 4-22-94 F 144.7 B 1 N/A N/A N/A Reactor Shutdown to Perform Maintenance on CRD Hydraulic Control Units Solenoid valves 6 4-30-94 F 14.0 B -
N/A N/A N/A Main Generator Manually Tripped Offline to Perform a Weld Repair on the Extraction Steam Line Entering the Train 'B'-
Second Point Feedwater Heater 1 2 2 3 4&5 F-FORCED A-Equip Failure F-Admin 1-Manual Exhibit F&H S-SCHED B+ Main or Test G-Oper Error 2-Manual Scram Instructions for C-Refueling H-Other 3-Auto Scram Preparations of D-Regulatory Restriction 4-Continued Data Entry Sheet E-Operator Training 5-Reduced Load Licensee Event Report
& License Examination 9-Other (LER) File (NUREG-1022) h k
_ _ _ _ . _ _ . _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ __ -_. _ _. _